• 제목/요약/키워드: failure stress measurement

검색결과 90건 처리시간 0.029초

Investigating loading rate and fibre densities influence on SRG - concrete bond behaviour

  • Jahangir, Hashem;Esfahani, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.877-889
    • /
    • 2020
  • This work features the outcomes of an empirical investigation into the characteristics of steel reinforced grout (SRG) composite - concrete interfaces. The parameters varied were loading rate, densities of steel fibres and types of load displacement responses or measurements (slip and machine grips). The following observations and results were derived from standard single-lap shear tests. Interfacial debonding of SRG - concrete joints is a function of both fracture of matrix along the bond interface and slippage of fibre. A change in the loading rate results in a variation in peak load (Pmax) and the correlative stress (σmax), slip and machine grips readings at measured peak load. Further analysis of load responses revealed that the behaviour of load responses is shaped by loading rate, fibre density as well as load response measurement variable. Notably, the out-of-plane displacement at peak load increased with increments in load rates and were independent of specimen fibre densities.

다층지반에서의 아칭현상에 의한 수직갱 토압 (Earth pressure of vertical shaft considering arching effect in layered soils)

  • 이인모;문홍표;이대수;김경렬;조만섭
    • 한국터널지하공간학회 논문집
    • /
    • 제9권1호
    • /
    • pp.49-62
    • /
    • 2007
  • 본 연구에서는 사질토 지반에 설치된 수직갱에 작용하는 토압에 대한 기존 제안식을 수정하였다. 이를 검증하기 위하여 깊이에 관계없이 동일한 반경방향 변위를 일으킬 수 있는 실내 모형시험장치를 개발하였으며, 벽면마찰각과 상대 밀도를 변수로 시험하였다. 실내 모형시험 결과는 수정식에서 접선방향 토압계수(수직응력에 대한 접선방향 응력 비)인 $\lambda$값을 $\lambda=1-sin\phi$$\lambda=1$을 사용하였을 경우의 토압 사이에 분포하였다. 다층지반에 설치된 원형수직갱 배면지반의 파괴면을 가정하고 수정식을 적용하여 다층지반에 설치된 원형수직갱에 작용하는 토압 산정방법을 제안하였다. 시공현장의 3개의 수직갱으로부터 계측 데이터를 획득하였으며 이를 토압으로 환산하여 제안된 방법을 검증하였다. 계측 데이터로부터 환산된 대부분의 환산 토압은 제안된 방법의 토압과 잘 일치하였다.

  • PDF

배양 심근세포에서 저농도 삼산화비소에 의한 산화적 스트레스 발생 (Oxidative Stress by Arsenic Trioxide in Cultured Rat Cardiomyocytes, $H_9C_2$ Cells)

  • 박은정;박광식
    • Environmental Analysis Health and Toxicology
    • /
    • 제21권1호
    • /
    • pp.71-79
    • /
    • 2006
  • Epidemiologic studies have showed a close correlation between arsenic exposure and heart disease such as, cardiovascular problem, ischemic heart disease, infarction, atherosclerosis and hypertension in human. It may increase the mortality of high risk group with heart disease. Regarding the mechanism studies of heart failure, blood vessel, vascular smooth muscle cells and endothelial cells have long been focused as the primary targets in arsenic exposure but there are only a few studies on the cardiomyocytes. In this study, the generation of oxidative stress by low dose of arsenic trioxide was investigated in rat cardiomyocytes. By direct measurement of reactive oxygen species and fluorescent microscopic observation using fluorescent dye 2',7'-dichlorofluorescin diacetate, reactive oxygen species were found to be generated without cell death, where cells are treated with 0.1 ppm arsenic for 24 hours. With the induction of reactive oxygen species, GSH level was decreased by the same treatment. However, DNA damage did not seem to be serious by DAPI staining, while high dose of arsenic (2 ppm for 24 hrs) caused fragmentation of DNA. To identify the molecular biomarkers of low-dose arsenic exposure, gene expression was also investigated with whole genome microarray. As results, 9,022 genes were up-regulated including heme oxygenase-l and glutathione S-transrerase, which are well-known biomarkers of oxidative stress. 9,404 genes were down-regulated including endothelial type gp 91-phox gene by the treatment of 0.1 ppm arsenic for 24 hours. This means that biological responses of cardiomyocytes may be altered by ROS induced by low level arsenic without cell death, and this alteration may be detected clearly by molecular biomarkers such as heme oxygenase-1.

시그모이드 함수를 이용한 다중 계측데이터 모니터링 시스템 (Multimetric Measurement Data Monitoring System Using Sigmoid Function)

  • 송정호;신준우;한희수
    • 지질공학
    • /
    • 제33권1호
    • /
    • pp.137-149
    • /
    • 2023
  • 구조물에 작용하는 토압의 방향과 장기변위상태변화를 직관적으로 파악하기 위해 수평, 수직방향의 변위 데이터를 시그모이드 함수를 이용하여 가공하고 각각 좌표계의 한 축으로 하여 변위좌표계 시스템을 설정하였다. 이러한 변위좌표계에 변위상태(압축 또는 팽창) 구분영역과 관리단계 구분영역 설정하여 각 계측지점의 변위상태와 관리단계를 직관적으로 확인할 수 있었다. 관측점을 연속적으로 나타내어 변위경로를 나타내었으며, 변위경로를 통해 변위이력, 변위추세, 지반에 작용하는 응력방향 등을 알 수 있었다. 흙막이 가시설의 실계측데이터 분석 결과 모든 계측지점에서 응력해방 방향으로 변위가 일어났으며, 정상관리상태에 위치하였다. 또한 공간적 상관성이 높은 계측지점 간 거동은 비슷한 거동추세를 보였으며, 공간적 상관성이 낮은 계측지점 간에는 상이한 거동 추세를 보였다. 공간적으로 연속되어 분포하는 지표침하데이터를 변위좌표계를 이용하여 전조현상과 거동영역에 대한 상관성 분석을 수행하면 파괴시간, 영역 예측이 가능 할 것으로 판단된다.

임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구 (THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS)

  • 박원희;이영수
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

반도체 배선용 저 유전 물질에서의 구리 확산에 대한 전기적 신뢰성 평가 (Characterization of Electrical Properties on Cu Diffusion in Low-k Dielectric Materials for ULSI Interconnect)

  • 이희찬;주영창;노현욱;윤도영;이진규;차국헌
    • 마이크로전자및패키징학회지
    • /
    • 제11권3호
    • /
    • pp.9-15
    • /
    • 2004
  • PMSSQ (Poly Methyl Silsesquioxane)-based matrix에 BTMSE (Bis Tri Methoxy Silyl Ethane) 를 첨가한 low-k물질의 전기적 특성을 조사하였다. 우리는 절연체로 copolymer를 사용하여 금속-절연체 -실리콘 구조를 만들고 BTS 실험을 통하여 누설 전류와 파괴 시간을 측정하였다. 코 폴리머의 기공이 $30\%$ 이상이 되었을 때, 파괴 시간이 급속하게 감소되어 진다. 온도에 관하여 파괴 시간으로부터 코 폴리머를 통한 구리 확산의 활성화 에너지는 1.51eV가 측정되었다.

  • PDF

재료 비선형과 연속체 손상역학을 고려한 복합 적층판의 강도 예측 (Strength Prediction on Composite Laminates Including Material Nonlinearity and Continuum Damage Mechanics)

  • 박국진;강희진;신상준;최익현;김민기;김승조
    • 한국항공우주학회지
    • /
    • 제42권11호
    • /
    • pp.927-936
    • /
    • 2014
  • 이 논문에서는 복합 적층판의 점진적 파손해석 기법을 개발하고 검증하였다. 강도 및 강성 예측의 정확성을 높이기 위해 재료 비선형 효과와 연속체 손상역학을 동시에 고려하였다. 파손 시작점과 성장을 예측하기 위한 식으로 Hashin의 판별식이 사용되었으며, 파손 모드는 수지인장/전단, 섬유 인장의 2가지 파손모드를 고려하였다. 비선형 탄성 및 점탄성의 구성방정식을 고려한 평형을 계산하기 위해 Newton-Raphson 방법이 사용되었다. 실험을 통해 얻어진 복합재료 단층의 물성을 이용하여 노치가 없는 시편에 인장력을 가했을 때 예상되는 적층복합재의 강도 및 변형률을 예측하였다. 이 경우 선형 물성과 저하계수만을 고려하여 예측된 강성/강도보다 실험결과에 근사하게 나타남을 확인하였다.

두께 감소된 배관 엘보우의 파손 모드에 대한 연구 (A Study on Failure Mode of Pipe Elbows with Wall Thinning)

  • 신규인;윤기봉
    • 한국가스학회지
    • /
    • 제12권2호
    • /
    • pp.57-62
    • /
    • 2008
  • 배관 엘보우의 내호면(intrados)의 과 내부에 국부적으로 두께 감육이 발생한 경우, 내압과 엘보우를 닫는 방향으로의 굽힘하중을 부가하여 파손 모드를 연구하였다. 탄소성해석 시 반력-변위 곡선이 세 그룹으로 나뉘므로 각 그룹의 한 경우씩을 해석하여 소성붕괴에 의한 파손모드의 차이를 확인하였다. 이를 위해 주요 부위에서 하중-국부적응력 곡선이 어떻게 변화하는지 결정하여, 이로부터 관찰된 파손모드와 비교하여 설명하였다. 감육폭이 $90^{\circ}$인 경우 배관은 엘보우 측면부터 소성붕괴가 시작되었으며, $360^{\circ}$인 경우 내호면으로부터 소성변형이 시작되어 서로 다른 파손모드를 보여주었다. 배관의 감육측정에 의한 건전성 평가 시 이와 같은 파손 모드의 차이점을 고려하여 평가를 실시하여야 한다.

  • PDF

열화되는 성능 파라메터를 가지는 시스템의 신뢰성 예측에 관한 연구 (A Study on Reliability Prediction of System with Degrading Performance Parameter)

  • 김연수;정영배
    • 산업경영시스템학회지
    • /
    • 제38권4호
    • /
    • pp.142-148
    • /
    • 2015
  • Due to advancements in technology and manufacturing capability, it is not uncommon that life tests yield no or few failures at low stress levels. In these situations it is difficult to analyse lifetime data and make meaningful inferences about product or system reliability. For some products or systems whose performance characteristics degrade over time, a failure is said to have occurred when a performance characteristic crosses a critical threshold. The measurements of the degradation characteristic contain much useful and credible information about product or system reliability. Degradation measurements of the performance characteristics of an unfailed unit at different times can directly relate reliability measures to physical characteristics. Reliability prediction based on physical performance measures can be an efficient and alternative method to estimate for some highly reliable parts or systems. If the degradation process and the distance between the last measurement and a specified threshold can be established, the remaining useful life is predicted in advance. In turn, this prediction leads to just in time maintenance decision to protect systems. In this paper, we describe techniques for mapping product or system which has degrading performance parameter to the associated classical reliability measures in the performance domain. This paper described a general modeling and analysis procedure for reliability prediction based on one dominant degradation performance characteristic considering pseudo degradation performance life trend model. This pseudo degradation trend model is based on probability modeling of a failure mechanism degradation trend and comparison of a projected distribution to pre-defined critical soft failure point in time or cycle.

대학생들의 스트레스 지각 정도와 경동맥 내막-중막 두께의 관계 연구 (The Relationship between Perceived Stress Scale and Carotid Intima-Media Thickness Using Ultrasonography in University Students)

  • 김대식;성현호;이종우;조은경
    • 대한임상검사과학회지
    • /
    • 제49권3호
    • /
    • pp.308-315
    • /
    • 2017
  • 경동맥 내막-중막 두께(CIMT) 검사는 심장 질환의 증상이 없는 환자에서도 안전하고 비 침습적으로 죽상경화증을 검사하고 모니터 할 수 있는 표준화 된 초음파 절차이다. 본 연구의 목적은 초음파로 측정 한 경동맥 내막-중막 두께와 환자의 스트레스 정도를 측정하는 것이었다. 연구 대상자는 경기도 수원시에 있는 기타 질환이 없는 대학생 168 명(남자 46 명, 여자 122 명)이었다. 이 연구에서 참가자들의 연구 참여는 문서를 통하여 개인적으로 동의를 받았다. 경동맥 내막-중막 두께는 비 침습성 고 해상도 Medison Accuvix V20 초음파 장비를 사용하여 분기점 아래 1 cm의 좌우 총경동맥에서 측정되었고, 스트레스 인지정도는 10 가지 항목의 PSS (Perceived Stress Scale)설문지를 이용하였다. 이 연구는 PSS가 인지된 스트레스 수준과 체중을 추정하는데 적절함을 나타냈다. 스트레스 유무에 따라 좌측 CIMT와 체중 간에 통계적으로 유의 한 차이가 있었다(p<0.05). 이 연구의 결과는 체중 측정이 부분적으로는 일반화 된 스트레스에 영향을 받는다는 것을 시사합니다. CIMT에 대한 인지된 스트레스와 일반화 된 불안의 영향을 테스트하기 위해서는 다양한 연구가 지속적으로 이루어져야 할 것으로 사료된다.