• Title/Summary/Keyword: failure patterns

Search Result 599, Processing Time 0.033 seconds

Characteristics of the Problem Solving Process of the Balancing Redox Equations by Senior and Science High School Students' Mental Capacity and Problem Solving Methdos (일반고와 과학고 학생들의 정신용량과 풀이 방법에 따른 산화 환원 반응식 완결 과정의 특성)

  • Kim, Chung-Ho;Lee, Sang-Gwon
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.353-363
    • /
    • 2002
  • In this study, characteristics of the problem solving process of the balancing redox equations was ana-lyzed by mental capacity and problem solving methods, and the pertinent teaching and learning guidance for oxidation-reduction unit was suggested. Participants were 79 senior high school students and 57 science high school students. Tests were conducted to measure the mental capacity, the understanding of the oxidation-reduction concepts and the com-pletion of the balancing redox equations. The framework was made to find the patterns of failure and success. As the analysis of the influence on the performance of mental capacity,understanding of the oxidation-reduction concepts, and problem solving methods, students who had lower understanding of oxidation-reduction concepts selected the trial and error method, and their performance were influenced by mental capacity. The students that had higher understanding of the oxidation-reduction concepts had good performance by using oxidation number method regardless of their mental capacity. As the results of analysis for the patterns, the success patterns of solving the problems, those of mostly the sci-ence high school students, were the cases of using oxidation number method well and lessening problem solving steps. The patterns of failure in solving problems by using trial and error method showed that students had mistakes in cal-culating, errors in making unknown equations, no consideration for all variables, or stopped solving the complicated problems. The patterns of failure in solving problems by using oxidation number method showed that many students had wrong oxidation number or no consideration for mass and charge balance.

Punching Shear Strength of Prestressed Precast Concrete Deck (프리스트레스를 도입한 프리캐스트 콘크리트 교량바닥판의 펀칭전단강도)

  • 정철헌;류형근;정운용;김인규
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.653-659
    • /
    • 2002
  • Recently, the failure case of the bridge deck slabs have been increasing in Korea and it was observed that the failure modes of most deck slabs collapsed were not caused by flexural moment but by local punching shear. The main reason of the failures was the punching shear failure of deck slabs under heavy truck traffics. This paper presents test results obtained from punching shear tests performed on prestressed precast deck specimens. Cracking patterns, failure modes, deflections, and stresses are included as well as discussion of the punching shear strength observed during punching shear tests. Static lest specimens had punching shear failures at loads much higher than predicted by the current codes. Tests results indicate that current code provisions appear to be conservative.

Experimental behavior and shear bearing capacity calculation of RC columns with a vertical splitting failure

  • Wang, Peng;Shi, Qing X.;Wang, Qiu W.;Tao, Yi
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1233-1250
    • /
    • 2015
  • The behavior of reinforced concrete (RC) columns made from high strength materials was investigated experimentally. Six high-strength concrete specimen columns (1:4 scale), which included three with high-strength transverse reinforcing bars and three with normal-strength transverse reinforcement, were tested under double curvature bending load. The effects of yielding strength and ratio of transverse reinforcement on the cracking patterns, hysteretic response, shear strength, ductility, strength reduction, energy dissipation and strain of reinforcement were studied. The test results indicated that all specimens failed in splitting failure, and specimens with high-strength transverse reinforcement exhibited better seismic performance than those with normal-strength transverse reinforcement. It also demonstrated that the strength of high-strength lateral reinforcing bars was fully utilized at the ultimate displacements. Shear strength formula of short concrete columns, which experienced a splitting failure, was proposed based on the Chinese concrete code. To enhance the applicability of the model, it was corroborated with 47 short concrete columns selected from the literature available. The results indicated that, the proposed method can give better predictions of shear strength for short columns that experienced a splitting failure than other shear strength models of ACI 318 and Chinese concrete codes.

Damage Index of Steel Members under Severe Cyclic Loading

  • Park, Yeon-soo;Han, Suk-yeol;Suh, Byoung-chal;Jeon, Dong-ho;Park, Sun-joon
    • Computational Structural Engineering : An International Journal
    • /
    • v.3 no.1
    • /
    • pp.9-17
    • /
    • 2003
  • This paper aims at investigating the damage process of steel members leading to the failure under strong repeated loading, proposing the damage index using various factors related to the damage, and developing the analysis method for evaluating the damage state. Cantilever-type steel members were analyzed under uniaxial load and combined with a constant axial load, considering a horizontal displacement history. In analyzing the models, loading patterns and steel types (SS400, SM570, Posten80) were considered as main parameters. From the analysis results, the effects of parameter on the failures mode, the deformation capacity, the damage process are also discussed. Each failure process was compared as steel types. Consequently, the failure of steel members under strong repeated loading was determined by loading. Especially it was seen that the state of the failure is closely related to the local strain.

  • PDF

Study on the Failure Mechanism of a Chip Resistor Solder Joint During Thermal Cycling for Prognostics and Health Monitoring (고장예지를 위한 온도사이클시험에서 칩저항 실장솔더의 고장메커니즘 연구)

  • Han, Chang-Woon;Park, Noh-Chang;Hong, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.799-804
    • /
    • 2011
  • A thermal cycling test was conducted on a chip resistor solder joint with real-time failure monitoring. In order to study the failure mechanism of the chip resistor solder joint during the test, the resistance between both ends of the resistor was monitored until the occurrence of failure. It was observed that the monitored resistance first fluctuated linearly according to the temperature change. The initial variation in the resistance occurred at the time during the cycle when there was a decrease in temperature. A more significant change in the resistance followed after a certain number of cycles, during the time when there was an increase in the temperature. In order to explain the failure patterns of the solder joint, a mechanism for the solder failure was suggested, and its validity was proved through FE simulations. Based on the explained failure mechanism, it was shown that prognostics for the solder failure can be implemented by monitoring the resistance change in a thermal cycle condition.

Evaluation of Failure Mode in Concrete Beam Restrengthened with GFRP with Various Initial Conditions (GFRP로 보강된 다양한 초기 조건의 콘크리트보의 파괴 거동 평가)

  • Jin-Won Nam;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2023
  • Various failure modes occur in the concrete beams reinforced with GFRP(Glass Fiber Reinforced Plastic) under initial condition and repairing patterns. In this study, the failure behaviors of concrete beams restrengthened with GFRP sheet with slightly higher elastic modulus than concrete were investigated. For the tests, concrete beams with 24 MPa were manufactured, and the effects of initial notch, overlapping, end-strip reinforcement, and fiber anchors were analyzed on failure load. The cases of GFRP overlap around notch and the initial notch showed increasing failure loads similar to those of normal restrengthened case since the epoxy of the saturated GFRP sufficiently repaired the notch area. Compared to the control case without restrengthening of GFRP, the concrete with initial notch showed 0.78 of loading ratio and normal restrengthening showed 4.43~5.61 times of increasing ratio of failure loading, where interface-debonding from flexural crack were mainly observed. The most ideal failure behavior, break of GFRP, was observed when end-strip over 1/3 height from bottom and fiber anchor were installed, which showed increasing failure load over 150 % to normal restrengthening.

Patterns of Failure after Combined Surgery and Radiation Therapy for Malignant Tumors of the Parotid Gland - Analysis of Treatment Results According to Pathologic Type - (근치적수술과 술후방사선치료를 받은 이하선 악성종양 환자의 치료실패 양상 - 병리학적 유형에 따른 결과를 중심으로 -)

  • Lee Sang-Wook;Chang Sei-Kyung;Kim Gwi-Eon;Suh Chang-Ok;Seong Jin-Sil;Lee Chang-Geol;Keum Ki-Chang;Park Cheong-Soo;Choi Eun-Chang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.182-188
    • /
    • 1999
  • Purpose: To investigate the treatment results' and patterns of failure according to the pathologic type of the parotid malignancy who were treated with radical sugery and postoperative radiation therapy. Materials and Methods: Fifty-two patients with various type of the parotid malignancy, who were treated with combined radical surgery and post-operative irradiation at Yonsei Cancer Center, between 1981 and 1995, were retrospectively reviewed after completion treatment, all but one patients were follow up with the median follow up period of 49 months. Results: We found that pathologically confirmed neck node metastasis rate was 28.8% all case and level II was most common site. Overall failure rate was 26.9%, local recurrence rate was 13.5%, node failure rate was 7.7%, and distant failure rate was 5.8%. Five-year disease free survival rate was 70.9%, and overall survival rate was 73.8%. Recurrence rate was low in adenoid cystic carcinoma and acinic cell carcinoma. However distant metastasis was very high in undifferentiated carcinoma. Local recurrence was main pattern of failure in mucoepidermoid carcinoma and nodal failure was frequently observed in adenocarcinoma. Conclusion: Individualized treatment plan may be required to improve a treatment outcome by pathologic subtype of the parotid malignancy.

  • PDF

Influence of undercut and surface crack on the stability of a vertical escarpment

  • Banerjee, Sounik K.;Chakraborty, Debarghya
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.965-981
    • /
    • 2017
  • Stability of vertical escarpments has been the subject of discussion for long time. However, available literature provides scarce knowledge about the effect of the formation of undercut and surface cracks on the stability of a vertical escarpment. The present study deals with a systematic analysis of the effect of surface cracks and undercut on slope stability using finite element based lower bound limit analysis. In the present analysis, the non-dimensional stability factor (${\gamma}H/c$) is used to inspect the degrading effect of undercut and cracks developed at different offset distances from the edge of the vertical escarpment. Failure patterns are also studied in detail to understand the extent and the type of failure zone which may generate during the state of collapse.

Micro-damage Process in Granite Under the State of Water-saturated Triaxial Compression (수침삼축압축하에서 관찰되는 화강암의 미세 파괴)

  • Yong Seok Seo;Gyo Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.9 no.3
    • /
    • pp.243-251
    • /
    • 1999
  • Granitic rock, by its nature, contains numerous micro-discontinuities including grain boundary, microcracks, microcavities and mineral cleavages. The brittle fracture of rock is a progressive procedure in which the failure occurs with prior microcracking. In this paper, initiation, propagation and interaction of microcracks are considered to be the dominant, controlling micromechanisms of macroscopic failure. The authors show a few patterns of microcrack initiation and propagation by using sequential photographs of water-saturated granite taken under triaxial compressive state. The failure process was observed directly and continuously by a newly developed triaxial compressive test system.

  • PDF

Shear Test on New Modified Double Tee Slabs including Service Ducts at the Ends (단부에 설비덕트를 포함하는 새로운 더블티 전단실험)

  • Kim Yun Soo;Song Hyung Soo;Ryu Jeong Wook;Lee Bo Kyung;Lee Jung Woo;Yu Sung Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.71-74
    • /
    • 2005
  • The increasement in the floor hight may be one of the most significant problem in the use of precast concrete double slab in the multi-story buildings. The modified double-tees including duct space at the ends of slab were considered in this study. The length and thickness of nib of modified double tee was increased to receive the uniform reaction from rectangular beam, while the original PCI dapped one to receive the point load from inverted tee beam to the leg of double tee. Shear tests were performed on the ends of the modified double tees which were designed by strut-tie model. The modified double tees generally show more ductile flexural failure in the long thickened nib. It is concluded that they show superior failure patterns than that of original dapped one with shear failure.

  • PDF