• Title/Summary/Keyword: failure parameters

Search Result 1,940, Processing Time 0.03 seconds

An Experimental Study on Stength of Slender Square Tube Columns Filled with High Strength Concrete (고강도콘크리트충전 각형강관장주의 내력에 관한 실험적 연구)

  • Seo, Seong Yeon;Chung, Jin An
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.471-479
    • /
    • 2002
  • In this paper, 18 square CFT columns filled with high-strength concrete were tested under concentric or eccentric axial loading. Two parameters of the experimental program included the buckling length-section depth ratio ($L_K$/D) and the eccentricity of the appled compressive load (e). In additon, mechanical properties such as the compressive concrete strength and compressive and tensile steel strength were measured and incorporated into the material models for the stress-strain relationships of concrete and steel. This model was used in an elasto-plastic analysis in order to predict the behavior of the slender CFT columns. Observtions of the failure mode during the tests under axial loadig were also presented. The strengths obtained from the analysis. Recommendations for Design, and Constructions of CFT structures were presented, as verified by the experimental results.

Effect of Temperature and Thickness on Fracture Toughness of Solid Propellant (고체추진제의 파괴인성에 대한 온도 및 두께의 영향)

  • Seo, Bo Hwi;Kim, Jae Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1355-1360
    • /
    • 2013
  • A cracked solid propellant would have failure or fracture of rocket because of excessive combustion according to increase of burning area, therefore it is important to evaluate the fracture toughness of solid propellant. A procedure is used to investigate the material under a range of test temperatures between -60 and $60^{\circ}C$, three kind of specimen thickness, 4, 12.5 and 24.5 mm to determine the effect of two parameters on the fracture toughness. A center cracked tension (CCT) specimen is used in these tests, which were conducted using INSTRON 5567 testing machine and environmental chamber to evaluate the fracture toughness. The experimental results show that the fracture toughness tends to decreases with an increase in the temperature, and the effect of thickness indicates that the fracture toughness is highest at 12.5 mm under various temperatures except $-60^{\circ}C$. It is found that the fracture toughness of solid propellant is changed due to glass transition behavior around $-60^{\circ}C$.

A Study on Electrochemical Polarization Test for Embrittlement Damage Evaluation of Aged Cr-Mo Steel (Cr-Mo강 시효재의 취화손상 평가를 위한 전기화학적 분극시험에 관한 연구)

  • Yu, Hyo-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.411-419
    • /
    • 1999
  • It has been well recognized that a long term service at elevated temperature of $350^{\circ}C{\sim}550^{\circ}C$ induces embrittlement damage due to carbide precipitation and/or P, Sb and Sn segregation at grain boundaries and thereby deteriorates the grain boundary strength of heat resisting components in the energy-related plants. Therefore, it is very important to assess quantitatively the extent of embrittlement damage of heat resisting components to secure the reliable and efficient service condition and to prevent brittle failure in service. However, because fracture tests are limited in size and number of specimen obtained from the structural components, nondestructive test method is required. In this study, the optimum electrochemical parameters are investigated and discussed to evaluate nondestructive embrittlement damage for aged 2.25Cr-1Mo steels by means of electrochemical polarization test method (ECPTM) in proper corrosive environment. In addition, the electrochemical test results are compared with embrittlement degree evaluated by semi-nondestructive SP test.

  • PDF

Study on stiffness deterioration in steel-concrete composite beams under fatigue loading

  • Wang, Bing;Huang, Qiao;Liu, Xiaoling;Ding, Yong
    • Steel and Composite Structures
    • /
    • v.34 no.4
    • /
    • pp.499-509
    • /
    • 2020
  • The purpose of this paper is to investigate the degradation law of stiffness of steel-concrete composite beams after certain fatigue loads. First, six test beams with stud connectors were designed and fabricated for static and fatigue tests. The resultant failure modes under different fatigue loading cycles were compared. And an analysis was performed for the variations in the load-deflection curves, residual deflections and relative slips of the composite beams during fatigue loading. Then, the correlations among the stiffness degradation of each test beam, the residual deflection and relative slip growth during the fatigue test were investigated, in order to clarify the primary reasons for the stiffness degradation of the composite beams. Finally, based on the stiffness degradation function under fatigue loading, a calculation model for the residual stiffness of composite beams in response to fatigue loading cycles was established by parameter fitting. The results show that the stiffness of composite beams undergoes irreversible degradation under fatigue loading. And stiffness degradation is associated with the macrobehavior of material fatigue damage and shear connection degradation. In addition, the stiffness degradation of the composite beams exhibit S-shaped monotonic decreasing trends with fatigue cycles. The general agreement between the calculation model and experiment shows good applicability of the proposed model for specific beam size and fatigue load parameters. Moreover, the research results provide a method for establishing a stiffness degradation model for composite beams after fatigue loading.

Seismic Performance Evaluation of Hexagonal Blocks Infilled RC Frames (육각형 블록을 이용한 채움벽 RC 골조의 채움벽 내진성능평가)

  • Chang, Kug Kwan;Seo, Dae Won;Ko, Tae Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.116-124
    • /
    • 2011
  • RC frames with unreinforced masonry infiledl walls are common in worldwide. Since infilled walls are normally considered as non-structural elements, their presence is often ignored by engineers. In this study, to improve the seismic performance of masonry walls, hexagonal block was developed and the influence of masonry infilled wall on the seismic performance of reinforced concrete(RC) frames that were designed in accordance with current code provisions without the consideration of earthquake loadings are investigated. Two 1/2 scale, single story, single bay, frame specimens were tested. The parameters investigated included that the strength of infilled wallls with respect to that of the lateral load history. The experimental results indicate that infilled walls can significantly improve the lateral stiffness and strength of RC frames. The lateral loads developed by the infilled frame specimen is higher than that of the bare frame. It also indicates that infilled walls can be potentially used to improve the performance of existing nonductile frames. For this purpose. methods should be developed to avoid irreparable damage and catastrophic failure.

Seismic Performane Evaluation of Flat Plate System Considering Column Aspect Ratio (무량판 구조시스템 접합부의 기둥 형상비에 따른 내진 성능 평가)

  • Lee, Hyun-Ho;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.74-80
    • /
    • 2008
  • This paper evaluates seismic capacities of slab-column joints in flat plate system which has columns with various aspect ratio as experimental parameters. Continuous - bended shear reinforcements were applied for the prevention of punching shear failure in this study. The specimens of FIS1-05, FIS1-10, and FIS1-20 have the aspect ratio of 0.5, 1.0, and 2.0 respectively. Static lateral force was applied to the specimens in a horizontal direction and vertical load was applied by constant gravity load ratio. The test results were evaluated by lateral displacement and strength of slab-column joint. Consequently, the lateral resisting capacity of rectangular type column such as FIS1-05, FIS1-20 is superior to the square type column such as FIS1-10.

A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports (DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

Population Dynamics of Zacco platypus in Gap-Stream and Its Relation with Water Quality

  • Shin, Young-Eun; Choi, Ji-Woon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.422-431
    • /
    • 2009
  • This study was to provide basic data for aquatic ecosystem research using fishes. Field sampling was carried out at five selected sites of Gap Stream, and fish samples, especially for a selection of sentinel species were collected three times in June, September, and October 2007. We analyzed total length distribution of Zacco platypus in relation with the season and the sampling sites, and then compared with total body weight, condition factor (K), and age distribution of the fish. The fish population data were compared with physico-chemical water quality, obtained from the Ministry of Environment, Korea. Water quality analysis showed a significant nutrient enrichment, based on total nitrogen (TN) and total phosphorus (TP), and organic matter pollution, based on biological oxygen demand (BOD) and chemical oxygen demand (COD) in the Site 5, which is directly influenced by wastewater disposal plant (WDP). Population analysis of the sentinel species showed that the total number of individuals, age distribution, and the population size-structure were influenced by the effluents from the WDP, and that reproductive failure of young-age population were evident in Site 5. According to the relation analysis of total weight to K, the disturbed population was mainly attributed to combined effects of habitat modifications and chemical degradations. Regression analysis of K values against water quality parameters showed significant (p<0.05) positive relations with nutrient and organic matter contents. Our data suggest that the population structure using a sentinel fish species reflected the ambient water quality in the stream and that diagnosis of aquatic ecosystem health using Z. platypus population may be practical for water resource and ecosystem conservations.

Flexural Strength of Reinforced Concrete Beams Containing Recycled Coarse Aggregate (순환굵은골재를 사용한 철근콘크리트 보의 휨강도)

  • Yang, In-Hwan;An, Seul-Ki;Hwang, Chul-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.30-39
    • /
    • 2017
  • This paper concerns flexural strength of reinforced concrete beams containing recycled coarse aggregate (RCA) with compressive strength ranging from 31 to 38 MPa. The experimental parameters were replacement ratio of RCA and rebar ratio. Replacement ratio of RCA was 0, 30, 50 and 100%, and rebar ratio was 0.50, 0.79 and 1.14%. The RCA concrete beams were tested by using four-point bending test, and experimental results were discussed regarding crack and failure patterns, load-deflection relationship. Crack pattern of concrete beams with RCA was similar to that of concrete beams with natural coarse aggregate (NCA) but overall crack spacing of concrete beams with RCA was smaller than that of concrete beams with NCA. The crack width of RCA and NCA concrete beams was similar to each other. In addition, the test results of flexural strength were compared to the design code predictions. The design code predictions for flexural strength underestimated the experimental results. Therefore, the design code predictions for flexural strength of RCA concrete beams would offer conservative design.

The Use of Reliability-based Approach to Design Anchored Sheet Pile Walls (신뢰성에 근거한 앵커 널말뚝의 설계방안 연구)

  • Kim, Hyung-Bae;Lee, Seoung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.95-104
    • /
    • 2002
  • In this study, a reliability-based design (RBD) procedure for determining design values fur anchored sheet pile wall is proposed considering overturning about the anchor point as the major failure mode. In this design procedure, the depth of embedment of the sheet pile wall is logically chosen in accordance with degrees of uncertainties of design input parameters using approximate probabilistic computation methods. These methods have been successfully used in the geotechnical engineering requiring neither understandings of complex probabilistic theories nor efforts to prepare more data. It was investigated that the design results by the proposed method were compatible with those by commonly used deterministic design methods. Additionally, in an effort to investigate the effects of changes in the degree of uncertainties of major design variables on the design results of the sheet pile wall, a sensitivity analysis was peformed.