• 제목/요약/키워드: failure of columns

검색결과 577건 처리시간 0.022초

Reinforced high-strength concrete square columns confined by aramid FRP jackets -part I: experimental study

  • Wang, Yuan-Feng;Ma, Yi-Shuo;Wu, Han-Liang
    • Steel and Composite Structures
    • /
    • 제11권6호
    • /
    • pp.455-468
    • /
    • 2011
  • Although retrofitting and strengthening reinforced concrete (RC) columns by wrapping fiber reinforced polymer (FRP) composites have become a popular technique in civil engineering, the study on reinforced high-strength concrete (HSC) columns is still not sufficient. The objective of these companion papers is to investigate the mechanical properties of reinforced HSC square columns confined by aramid FRP (AFRP) jackets under concentric compressive loading. In the part I of these companion papers, an experiment was conducted on 54 confined RC specimens and nine unconfined plain specimens, the considered parameters were the concrete strength, the thickness of AFRP jackets, and the form of AFRP wrapping. The experimental process and results are presented in detail. Subsequently, some discussions on the confinement effect, failure modes, strength, and ductility of the columns are carried out.

지진하중을 받는 철근콘크리트 원형교각의 전단성능곡선 모델 (Shear Capacity Curve Model for Circular RC Bridge Columns under Seismic Loads)

  • 이재훈;고성현;정영수
    • 한국지진공학회논문집
    • /
    • 제10권2호
    • /
    • pp.1-10
    • /
    • 2006
  • 형상비가 상대적으로 작은 철근콘크리트 교각에 지진작용으로 인한 반복 횡하중이 작용하면 초기단계와 중간단계의 변위에서는 휨 거동을 보이다가 최종변위단계에서는 전단에 의해 파괴되는 휨-전단 거동을 보인다. 휨-전단 파괴거동을 보이는 교각은 휨 파괴거동을 보이는 교각에 비하여 연성능력이 저하되므로, 내진설계 또는 내진성능평가에서 극한변위를 해석적으로 결정하기 위해서는 휨성능곡선과 함께 전단성능곡선 모델을 적용하여야 한다. 본 논문에서는 원형교각에 대한 기존 모델을 수정한 전단성능곡선 모델을 제안하였고, CALTRANS 모델, Aschheim등의 모델, Priestley 등의 모델, 제안모델의 특징을 비교하였다. 또 국내에서 수행된 실물크기 기둥 실험체를 대상으로 전단성능곡선 모델을 평가하였다. 제한된 범위의 소수 실험결과에 대한 적용으로서 일반화하기는 어려울 것이지만, 실험결과와 비교 검토한 결과 제안모델이 파괴형태의 예측과 변위성능 예측의 정확도에서 매우 우수한 것으로 평가되었다.

Strengthening of preloaded RC columns by post compressed plates-a review

  • Wang, L.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • 제65권4호
    • /
    • pp.477-490
    • /
    • 2018
  • Reinforced concrete (RC) columns, as the primary load-bearing structural components in buildings, may need to be strengthened due to material deteriorations, changes in usage, new building codes or new design requirements. The use of post compressed plates (PCP) to strengthen existing RC columns has been proven experimentally and practically to be effective in solving stress-lagging effects between the original column and the new strengthening jacket caused by the pre-existing loads. This paper presents a comprehensive summary and review of PCP strengthening techniques to strengthen preloaded RC columns. The failure mode, deformability, and ductility of the strengthened RC columns are reviewed.

기계적 정착된 전단보강근을 가진 RC 기둥의 구조적 거동 (Structural Behavior of RC Columns with Mechanically Anchored Crossties under Cyclic Loading)

  • 이성호;천성철;오보환;나환선;김상구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.59-62
    • /
    • 2005
  • Seven columns laterally reinforced with either mechanically anchored crossties or conventional crossties under cyclic loading are tested. 4 columns are specimens for flexural strength and 3 columns are for shear strength. Main variable is anchorage types of crossties. Conventional hooks, 180$^{\circ}$ standard hook-mechanical anchorage and all mechanical anchorage type are used. The specimens are tested under 10$\%$ axial load of nominal axial capacity of the columns combined with increasing lateral load. From the flexure test, it is found that columns with mechanical anchorages exhibit superior performance in terms of ductility and energy dissipation. The crossties with mechanical anchorages reduce buckling length of longitudinal rebar. From the shear test, it is found that. 3 specimens exhibit almost the same strength, displacement, and shear failure mode at ductility factor =2.

  • PDF

Experimental studies and numerical analysis of the shear behavior of fin plates to tubular columns at ambient and elevated temperatures

  • Jones, M.H.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.179-200
    • /
    • 2008
  • This paper reports the results of a recent experimental study into the behavior of welded fin-plate connections to both hollow and concrete filled tubular (CFT) columns under shear. Experiments have been performed at both ambient and elevated temperatures with the aid of an electric kiln. The observed failure modes include fracture of the fin plate and tearing out of the tube around the welds. By considering the results of previously published research, the current design method for similar connections under purely tensile load, in CIDECT Guide 9, based on a deformation limit of 3% of the tube width is shown to be inadequate when evaluating the ultimate strength of such connections. By comparing the results from the current test program which failed in the fin-plate with Eurocode guidance for failure of a fin-plate alone under shear and bending load it is shown that the column face influences the overall connection strength regardless of failure mode. Concrete in-fill is observed to significantly increase the strength of connections over empty specimens, and circular column specimens were observed to exhibit greater strength than similarly proportioned square columns. A finite element (F.E.) model, developed using ABAQUS, is presented and validated against the experimental results in order that extensive parametric tests may be subsequently performed. When validating the model against elevated temperature tests it was found that using reduction factors suggested in published research for the specific steel grades improved results over applying the generic Eurocode elevated temperature steel strength reduction factors.

Axial compressive behavior of high strength concrete-filled circular thin-walled steel tube columns with reinforcements

  • Meng Chen;Yuxin Cao;Ye Yao
    • Structural Engineering and Mechanics
    • /
    • 제88권1호
    • /
    • pp.95-107
    • /
    • 2023
  • In this study, circular thin-walled reinforced high strength concrete-filled steel tube (RHSCFST) stub columns with various tube thicknesses (i.e., 1.8, 2.5 and 3.0mm) and reinforcement ratios (i.e., 0, 1.6%, 2.4% and 3.2%) were fabricated to explore the influence of these factors on the axial compressive behavior of RHSCFST. The obtained test results show that the failure mode of RHSCFST transforms from outward buckling and tearing failure to drum failure with the increasing tube thickness. With the tube thickness and reinforcement ratio increased, the ultimate load-carrying capacity, compressive stiffness and ductility of columns increased, while the lateral strain in the stirrup decreased. Comparisons were also made between test results and the existing codes such as AIJ (2008), BS5400 (2005), ACI (2019) and EC4 (2010). It has been found that the existing codes provide conservative predictions for the ultimate load-carrying capacity of RHSCFST. Therefore, an accurate model for the prediction of the ultimate load-carrying capacity of circular thin-walled RHSCFST considering the steel reinforcement is developed, based on the obtained experimental results. It has been found that the model proposed in this study provides more accurate predictions of the ultimate load-carrying capacity than that from existing design codes.

Zr-Ni계 지연관 결합체(K1) 저장수명 향상 (Storage Lifetime Improvement of Zr-Ni K1 Delay System)

  • 장일호;백승준;정은진;손영갑
    • 한국군사과학기술학회지
    • /
    • 제13권2호
    • /
    • pp.336-341
    • /
    • 2010
  • The burning interruption between the initiator and the delay column in a Zr-Ni K1 delay system used for a K510 fuze occurs with long-time storage. About 10 % failure probability of 15-years stored delay systems shows the failure mode in open literature. This paper shows storage lifetime improvement results for the delay system through changing the single-base delay column into double-base ones and controlling the manufacturing processes especially the initial inclusion of humidity. The double-base delay columns was implemented by inserting one delay column of fast burning rates between the initiator and the previous delay column of slow burning rates. Accelerated aging tests of the delay systems with double-base columns, and then the firing tests were performed to evaluate the improved lifetime. The double-base delay columns shows improved storage lifetime of the delay system through preventing the failure mode.

초기 손상을 입은 비연성 철근콘크리트 골조의 FRP재킷으로 보수된 기둥의 수치해석모델 (Numerical Column Model for Damaged Non-ductile Reinforced Concrete Frame Repaired Using FRP Jacketing System)

  • 신지욱;전종수;김준희
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.291-298
    • /
    • 2018
  • Existing reinforced concrete building structures have seismic vulnerabilities under successive earthquakes (or mainshock-aftershock sequences) due to their inadequate column detailing, which leads to shear failure in the columns. To improve the shear capacity and ductility of the shear-critical columns, a fiber-reinforced polymer jacketing system has been widely used for seismic retrofit and repair. This study proposed a numerical modeling technique for damaged reinforced concrete columns repaired using the fiber-reinforced polymer jacketing system and validated the numerical responses with past experimental results. The column model well captured the experimental results in terms of lateral forces, stiffness, energy dissipation and failure modes. The proposed column modeling method enables to predict post-repair effects on structures initially damaged by mainshock.

장방형 철근 콘크리트 기둥의 띠철근량에 관한 해석적 연구 (Analytical Study on the Amount of Transverse Steel in Square Reinforced Concrete Columns.)

  • 이리형;김성수;이용택;김승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.453-458
    • /
    • 1996
  • In reinforced concrete structure, it is very important to secure ductile performance of column because the columns become brittle failure and cause the collapse of an entire structure and the damage of human life. This study is intending to seek the quantity of transverse steels in square reinforced concrete columns which is derived from moment-curvature analysis of cross section about various arrangements of transverse steel and the ratio of axial force and to propose the design method to secure the sufficient ductile behavior subjected to complex loading.

  • PDF

철근콘크리트 기둥의 전단강도 산정을 위한 스트럿 타이 모델 (Strut-and-Tie Model for Shear Strength of R/C Columns)

  • 이수곤;하태훈;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.591-596
    • /
    • 1999
  • Current design methods as well as the majority of the previous researches for shear strength of the reinforced concrete are based on empirical method. There is a need to propose the rational models based on analytical approach. This paper presents the modified strut-and-tie model for reinforced concrete columns, under axial compression, shear, and flexural moment, considering tensile strength of concrete. Using this model, the strength and the failure mode of R/C columns are investigated, and the proposed models are compared with test data available in the literature.

  • PDF