• Title/Summary/Keyword: failure event

Search Result 467, Processing Time 0.022 seconds

Cluster and information entropy analysis of acoustic emission during rock failure process

  • Zhang, Zhenghu;Hu, Lihua;Liu, Tiexin;Zheng, Hongchun;Tang, Chun'an
    • Geomechanics and Engineering
    • /
    • v.25 no.2
    • /
    • pp.135-142
    • /
    • 2021
  • This study provided a new research perspective for processing and analyzing AE data to evaluate rock failure. Cluster method and information entropy theory were introduced to investigate temporal and spatial correlation of acoustic emission (AE) events during the rock failure process. Laboratory experiments of granite subjected to compression were carried out, accompanied by real-time acoustic emission monitoring. The cumulative length and dip angle curves of single links were fitted by different distribution models and distribution functions of link length and directionality were determined. Spatial scale and directionality of AE event distribution, which are characterized by two parameters, i.e., spatial correlation length and spatial correlation directionality, were studied with the normalized applied stress. The entropies of link length and link directionality were also discussed. The results show that the distribution of accumulative link length and directionality obeys Weibull distribution. Spatial correlation length shows an upward trend preceding rock failure, while there are no remarkable upward or downward trends in spatial correlation directionality. There are obvious downward trends in entropies of link length and directionality. This research could enrich mathematical methods for processing AE data and facilitate the early-warning of rock failure-related geological disasters.

Successful vs. Failed Tech Start-ups in India: What Are the Distinctive Features?

  • Kalyanasundaram, Ganesaraman;Ramachandrula, Sitaram;Subrahmanya MH, Bala
    • Asian Journal of Innovation and Policy
    • /
    • v.9 no.3
    • /
    • pp.308-338
    • /
    • 2020
  • The entrepreneurial journey is not short of challenges, and about 90% + tech start-ups experience failure (Startup Genome, 2019). The magnitude of the challenges varies across the tech start-up lifecycle stages, namely emergence, stability, and growth. This opens the research question, do the profiles of a start-up and its co-founder impact start-up success or failure across its lifecycle stages? This study aims to understand and identify the profiles of tech start-ups and their co-founders. We gathered primary data from 151 start-ups (Status: 101 failed and 50 successful ones), and they are across different lifecycle stages and represent six major start-up hubs in India. The chi-square test on status and start-up's lifecycle stage indicates a noticeable correlation, and they are not independent. The Kruskal Wallis test was used to distinguish statistically significant profile attributes. The parameters distinguishing success and failure are identified, and the need to deliver customer experience is emphasized by the start-up profile attributes: Product/service, high-tech nature of a start-up, investor fund availed, co-founder experience, and employee count. The importance of entrepreneurial experience is ascertained with entrepreneur profile attributes: Entrepreneurial expertise, the number of prior and current start-ups, their willingness to start again in the event of failure, and age of co-founder, which is a proxy to learning and experience. This study has implications for entrepreneurs, investors, and policymakers.

A Study on FTA of Off-Site Packaged Hydrogen Station (Off-Site 패키지형 수소충전소의 FTA 분석)

  • SEO, DOO HYOUN;KIM, TAE HUN;RHIE, KWANG WON;CHOI, YOUNG EUN
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.73-81
    • /
    • 2020
  • For the fault tree analysis (FTA) analysis of the packaged hydrogen filling station, the composition of the charging station was analyzed and the fault tree (FT) diagram was prepared. FT diagrams were created by dividing the causes of events into external factors and internal factors with the hydrogen event as the top event. The external factors include the effects of major disasters caused by natural disasters and external factors as OR gates. Internal factors are divided into tube tailer, compressor & storage tank, and dispenser, which are composed of mistakes in operation process and causes of accidents caused by parts leakage. In this study, the purpose was to improve the hydrogen station. The subjects of this study were domestic packaged hydrogen stations and FTA study was conducted based on the previous studies, failure mode & effect analysis (FMEA) and hazard & operability study (HAZOP). Top event as a hydrogen leaking event and constructed the flow of events based on the previous study. Refer to "Off shore and onshore reliability data 6th edition", "European Industry Reliability Data Bank", technique for human error rate prediction (THERP) for reliability data. We hope that this study will help to improve the safety and activation of the hydrogen station.

Application Cases of Risk Assessment for British Railtrack System (영국철도시스템에 적용된 리스크평가 사례)

  • Lee, Dong-Ha;Jeong, Gwang-Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.81-94
    • /
    • 2003
  • The British railway safety research group has developed a risk assessment model for the railway infrastructure and major railway accidents. The major hazardous factors of the railway infrastructure were identified and classified in the model. The frequency rates of critical top events were predicted by the fault tree analysis method using failure data of the railway system components and ratings of railway maintenance experts, The consequences of critical top events were predicted by the event tree analysis method. They classified the Joss of accident due to railway system into personal. commercial and environmental damages. They also classified 110 hazardous event due to railway system into three categories. train accident. movement accident and non-movement accident. The risk assessment model of the British railway system has been designed to take full account of both the high frequency low consequence type events (events occurring routinely for which there is significant quantity of recorded data) and the low frequency high consequence events (events occurring rarely for which there is little recorded data). The results for each hazardous event were presented in terms of the frequency of occurrence (number of events/year) and the risk (number of equivalent fatalities per year).

A Review of HAZID/Bowtie Methodology and its Improvement (해지드/보우타이 기법의 한계와 개선에 대하여)

  • Kim, Sung-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.3
    • /
    • pp.164-172
    • /
    • 2022
  • A HAZID is a brainstorming workshop to identify hazards in an early phase of a project. It should be flexible to capture all probable accidents allowing experienced participants to exploit their expertise and experiences. A bowtie analysis is a graphical representation of major accident hazards elaborating safety measures i.e. barriers. The result of these workshops should be documented in an organized manner to share as good as possible details of the discussion through the lifetime of the project. Currently results are documented using a three-step representation of an accident; causes, top event and consequences, which cannot capture correctly sequence of events leading to various accidents and roles of barrier between two events. Another problem is that barriers would be shown repeatedly leading to a misunderstanding that there are an enough number of safety measures. A new bowtie analysis method is proposed to describe an accident in multiple steps showing relations among causes or consequences. With causes and consequences shown in a format of a tree, the frequencies of having the top event (Fault tree analysis) and various consequences (Event tree analysis) are evaluated automatically based on the frequency of initiating causes and the probabilities of failure of barriers. It will provide a good description of the accident scenario and help the risk to be assessed transparently.

Slope Failure Predicting Method Using the Monitoring of Volumetric Water Content in Soil Slope (흙사면의 체적함수비 계측을 통한 사면파괴 예측기법 개발)

  • Kim Man-Il;Nishigaki Makoto
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.135-143
    • /
    • 2006
  • This study presents the results of a series of laboratory scale slope failure experiments aimed at clarifying the process and the condition leading to the initiation of rainfall-induced slope failures. For the evaluation of hydrologic response of the model slopes in relation the process of failure initiation, measurements were focused on the changes in volumetric water content during the initiation process. The process leading to failure initiation commences by the development of a seepage face. It appears reasonable to conclude that slope failures are a consequence of the instability of seepage area formed at the slope surface during rainfall period. Therefore, this demonstrates the importance of monitoring the development seepage area for useful prediction about the timing of a particular failure event. The hydrologic response of soil slopes leading to failure initiation is characterized by three phases (phase I, II and III) of significant increase in volumetric water content in association with the ingress of wetting front and the rise of groundwater level within the slope. The period of phase III increase in volumetric water content can be used to initiate advance warning towards a failure initiation event. Therefore, for the concept outlined above, direct and continuous monitoring of the change in volumetric water content is likely to provide the possibility for the development of a reliable and effective means of predicting the occurrence of rainfall-induced slope failures.

The Fluctuation Patterns of Conjunctivitis Cases Caused by Asian Dust Storm (ADS) : Focused on the ADS Density and the Accuracy of ADS Forecast (황사예보 및 황사농도에 따른 결막염 질환의 발생 패턴 분석)

  • Lee, Ki-Kwang
    • Korean Management Science Review
    • /
    • v.30 no.1
    • /
    • pp.91-102
    • /
    • 2013
  • This study has an aim to analyze the effects of ADS on conjunctivitis patients among the residents of Seoul, Korea, between 2005 and 2008. For this purpose, the number of medical services provided to conjunctivitis patients on the days of windblown dust storms and the days without any windblown dust storms were analyzed by conducting paired t-test. The interactive effects of the ADS density and the accuracy of ADS forecast on the fluctuation of conjunctivitis cases were also investigated. The results showed that, even with an accurate forecast issued 24 hours prior to the event, the average number of medical services provided for conjunctivitis was higher on the index days than the comparison days. On the other hand, in cases of failure to provide an accurate forecast 24 hours prior to the ADS event, the number of conjunctivitis attacks reported was statistically significantly higher on the index days for 3~5 days after the occurrence of a dust storm in relation to the comparison days. We also found that the rate of increase in asthma treatments on the index days with low level of $PM_{10}$ concentration rather than high $PM_{10}$ level was more significant for all lag days. This study provides evidence that ADS events are significantly associated with conjunctivitis symptoms and the failure to forecast ADS events with low $PM_{10}$ level might aggravate conjunctivitis disease.

The Effect of Photoluminescent Exit Path Markings in Evacuation from Buildings (건축물 내에서 축광유도타일이 피난에 미치는 영향)

  • Hur, Man-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.67-72
    • /
    • 2005
  • This study is intended to examine the effect of photoluminescent exit path markings in the event of failure of both the power and back-up power to the lighting and illuminated exit sign. To achieve the purpose, the test house was exhibited in Fire EXPO '05. 520 visitors were examined from May 26-29, 2005. The results of this study are as follows; The evacuation from buildings in dark conditions showed that 70% of men and 72% of women were crawled along the wall. Meanwhile, 88% of men and 83% of women were evacuated with ordinary walking in photoluminescent exit path markings. The photoluminescent exit path markings located on public buildings floors will aid in evacuation from buildings in the event of failure of the power to the lightings and illuminated exit signs.

On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor (온도센서를 이용한 전력설비의 온라인 상태 감시)

  • Choi, Yong-Sung;Kim, Sun- Jae;Kim, Yeong-Min;Song, Hwao-Kee;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

An Investigation of Fire Human Reliability Analysis (HRA) Factors for Quantification of Post-fire Operator Manual Actions (OMA) (화재 후 운전원수동조치(OMA) 정량화를 위한 화재 인간신뢰도분석 (HRA) 요소에 대한 고찰)

  • Sun Yeong Choi;Dae Il Kang;Yong Hun Jung
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.72-78
    • /
    • 2023
  • The purpose of this paper is to derive a quantified approach for Operator Manual Actions (OMAs) based on the existing fire Human Reliability Analysis (HRA) methodology developed by the Korea Atomic Energy Research Institute (KAERI). The existing fire HRA method was reviewed, and supplementary considerations for OMA quantification were established through a comparative analysis with NUREG-1852 criteria and the review of the existing literature. The OMA quantification approach involves a timeline that considers the occurrence of Multiple Spurious Operations (MSOs) during a Main Control Room Abandonment (MCRA) determination and movement towards the Remote Shutdown Panel (RSP) in the event of a Main Control Room (MCR) fire. The derived failure probability of an OMA from the approach proposed in this paper is expected to enhance the understanding of its reliability. Therefore, it allows moving beyond the deterministic classification of "reliable" or "unreliable" in NUREG-1852. Also, in the event of a nuclear power plant fire where multiple OMAs are required within a critical time range, it is anticipated that the OMA failure probability could serve as a criterion for prioritizing OMAs and determining their order of importance.