Automated Maintenance Inspection System for Unmanned Surveillance Equipment (무인감시설비를 위한 유지보수 자동화 점검 시스템)

  • Chae, Min-Uk;Lee, Choong Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Recently, unmanned facilities have been introduced and operated in a way that reduces the cost and development of IT technology. Although unmanned facilities have advantages in terms of efficiency and economy, they have disadvantages such as failure of unmanned facilities and malfunctions, causing damage to facilities caused by intruders, and information leakage. In addition, it is necessary to visit the person in charge at all times to inspect the unmanned facilities, resulting in management costs. In this paper, we designed a system that checks the status of unmanned surveillance facilities in real time to check and automatically recover problems such as malfunctions, and to notify managers of situations by text messages in real time. The system to be designed consists of an integrated network video server (NVR) that receives and determines information on the operation status of the main equipment such as video, sound, and lighting, and a real-time text message using an SMS server.

Family history of chronic renal failure is associated with malnutrition in Korean hemodialysis patients

  • Hwang, Ji-Yun;Cho, Ju-Hyun;Lee, Yoon-Jung;Jang, Sang-Pil;Kim, Wha-Young
    • Nutrition Research and Practice
    • /
    • v.3 no.3
    • /
    • pp.247-252
    • /
    • 2009
  • The present study was to investigate the nutritional status and factors related to malnutrition in end-stage renal disease (ESRD) patients requiring hemodialysis (HD) in South Korea. Subjects were ESRD outpatients from general hospitals or HD centers in Seoul referred to the dialysis clinic for maintenance HD care. A total of 110 patients (46 men and 64 women; mean ages $58.6{\pm}1.0y$) were eligible for this study. The family history of chronic renal failure (CRF) was considered positive if a patient reported having either a first-degree or second-degree relative with CRF. Malnutrition was defined as a triceps skinfold thickness or mid-ann muscle circumference below the fifth percentile for age and sex and forty-seven of the 110 patients were malnourished. Almost all (94%) patients had anemia (hemoglobin: <13 g/dL for men and <12 g/dL for women). Energy intake was below the recommended intake levels of energy [30-35 kcal/kg ideal body weight (IBW)] and protein (1.2 g/kg IBW) in 60% of patients. The duration of HD was longer in malnourished HD patients (P=0.0095). Malnutrition was more prevalent in women (P=0.0014), those who never smoked (P=0.0007), nondiabetic patients (P=0.0113), and patients with bone diseases (P=0.0427), adequate HD (spKt/$V{\geq}1.2$) (P=0.0178), and those with a family history of CRF (P=0.0255). Multiple logistic regression was used to examine the relationship between malnutrition and potential risk factors. After adjusting for age, sex, and other putative risk factors for malnutrition, the OR for malnutrition was greater in HD patients with a family history of CRF (OR, 3.290; 95% CI, $1.003{sim}10.793$). Active nutrition monitoring is needed to improve the nutritional status of HD patients. A family history of CRF may be an independent risk factor for malnutrition in Korean HD patients. A follow-up study is needed to investigate whether there is a causal relationship between a family history of CRF and malnutrition in Korean ESRD patients.

A Study on How to Extend The Inspection Period for The One-Shot System (One-Shot System에 대한 점검주기 연장 방안 연구)

  • Kim, Jong-jin;Song, Jeong-hun;Han, Jung-won;Lee, Chang-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.113-118
    • /
    • 2021
  • The guided weapon system should ensure economical operation and user safety. In particular, in the case of guided weapon systems developed in the form of a guaranteed bomb, the standards for maintaining reliability considering the long-term storage environment are presented during the development stage, and an optimized inspection cycle is required to maintain this. This study calculated the reliability through a trend test, fitness test, and distribution analysis using a mathematical model based on the maintenance status and shooting results during the inspection period for OO missiles currently in operation for a long time in the military. Through this, it was applied to the inspection period model (Martinez) set during the development stage to determine if the improved inspection period can be utilized. Finally, by synthesizing the data from these studies, a policy management plan was developed according to the extension of the inspection period. The One-Shot system was operated at the inspection period set when it was developed. The study analyzed the actual failure and maintenance data to reset the efficient inspection period.

Development and Performance Improvement of old Aluminum Extruder Remanufacturing Technology (노후된 알루미늄 압출기의 재제조 기술 개발 및 성능 개선)

  • Sang-Min Yoon;Hang-Chul Jung;Man-Seek Kong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.95-103
    • /
    • 2023
  • The domestic remanufacturing industry is concentrated in auto parts, so it is necessary to expand into various industries. In the domestic aluminum industry, the extrusion process accounts for more than 40% of the total, but the old and management of the extrusion equipment is not done properly. In particular, the extruder has a structure in which equipment is not replaced until major parts are damaged or worn, so there are problems such as lower process precision, productivity and production efficiency compared to new equipment, and high maintenance costs. In this study, the old extruder was remanufactured for major high-risk parts through Failure Mode and Effect Analysis(FMEA), and the process level and performance of the extruder were evaluated before and after remanufacturing. Compared to the existing extruder, the standard deviation of the remanufacture extruder was reduced by 93.5%, 57.9%, and 70.0%, respectively, in major process control items such as container temperature, billet temperature, and ram speed, keeping performance constant. In addition, it was possible to produce products with complex shapes that could not be produced before due to problems such as dimensional deviation within tolerances. In this study, remanufacturing guidelines were presented by analyzing the effect of failure modes of the old extruder, and the performance improvement of the extruder was confirmed.

Assessing landslide susceptibility along the Halong - Vandon expressway in Quang Ninh province, Vietnam: A comprehensive approach integrating GIS and various methods

  • Nguyen-Vu Luat;Tuan-Nghia Do;Lan Chau Nguyen;Nguyen Trung Kien
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.135-147
    • /
    • 2024
  • A GIS-based landslide susceptibility mapping (LSM) was carried out using frequency ratio (FR), modified frequency ratio (M-FR), analytic hierarchy process (AHP), and modified analytic hierarchy process (M-AHP) methods to identify and delineate the potential failure zones along the Halong - Vandon expressway. The thematic layers of various landslide causative factors were generated for modeling in GIS, including geology, rainfall, distance to fault, distance to road, slope, aspect, landuse, density of landslide, vertical relief, and horizontal relief. In addition, a landslide inventory along the road network was prepared using data provided by the management department during the course of construction and operation from 2017 to 2019, when many landslides were documented. The validation results showed that the M-FR method had the highest AUC value (AUC = 0.971), which was followed by the FR method with AUC = 0.961. The AUC values were 0.939 and 0.892 for the M-AHP and AHP methods, respectively. The generated LSM obtained from M-FR method classified the study area into five susceptibility classes: very low (0), low (0-1), moderate (1-2), high (2-3), and very high (3-4) classes, which could be useful for various stakeholders like planners, engineers, designers, and local public for future construction and maintenance in the study area.

Development of fault detection and diagnosis system for the heat source apparatus of building air-conditioning system (공조시스템의 열원기기에 대한 고장검출 및 진단 시스템 개발)

  • Han, Dong-Won;Park, Jong-Soo;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.30-35
    • /
    • 2008
  • This paper describes a fault detection and diagnosis (FDD) system developed for the heat source apparatus in building air-conditioning system. As HVAC&R systems in building become complex and instrumented with highly automated controllers, the processes and systems get more difficult for the operator to understand and detect the mal-functions. Poorly maintained, degraded, and improperly controlled equipment wastes an estimated 15% to 30% of energy used in commercial building. When operating a complex facility, FDD system is beneficial in equipment management to provide the operator with tools which can help in decision making for recovery from a failure of the system. Automated FDD for HVAC&R system has the potential to reduce energy and maintenance costs and improves comfort and reliability. Over the last decade there has been considerable research for developing FDD system for HVAC&R equipment. However, they are being made too much of a theoretical study, so only a small of FDD methods are deployed in the field. This study deduced an actual defect source for the heat source apparatus and suggested a low price FDD method which is ready to be deployed in the field.

  • PDF

Development of Levee Safety Revaluation for Satellite Images (위성 이미지를 활용한 제방 안정성 평가 기법 개발)

  • Bang, Young Jun;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.3
    • /
    • pp.1-14
    • /
    • 2022
  • Recently, the risk of water disasters are increasing due to climate change and the aging of river levees. Existing conventional river embankment inspections have many limitations due to the consumption of a lot of manpower and budget. Thus, it is necessary to establish a new monitoring and forecast/warning method for effective flood response. This study proposes the river levee health monitoring system by analyzing the relationship between river levee deformation and hydrological factors using Sentinel-1. The variance index calculated in this study was classified into 4 grades. And the levees collapse section was judged to be a high vulnerable point in which the variance rapidly increased based on the result of the rapid increase in soil moisture. In the future, it is expected that it will be possible to advance levee maintenance technology and improve national disaster management through the advancement of the existing levee management system and automated monitoring through the forensic method that combines remote technology.

A Study on Promoting the Efficiency of Aircraft System Safety Assessment (항공기 시스템 안전성평가 효율화 방안 연구)

  • Yoo, Seung-woo;Lee, Jong-hee
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.3
    • /
    • pp.7-12
    • /
    • 2012
  • The contents of aircraft system safety assessment vary depending on factors such as the complexity of the system, how critical the system is to flight safety, what volume of experience is available on the type of system and the novelty and complexity of the technologies being used. If the system safety assessment is to substantiate that the developed products are 'safe enough' to be taken into use, then the system safety assessment should be planned and managed to provide the necessary assurance that all relevant hazards and failure conditions have been identified and that all significant combinations of hazards and failures which could cause those conditions have been considered. The assessment must assist the designer and management in making decisions. It must make clear what the critical features of each system are and upon which special manufacturing techniques, inspection, testing, crew drills and maintenance practice they are critically dependent. This paper has prepared to study on promoting the efficiency of aircraft system safety assessment and to present how to compile system safety assessment strategy.

A technology State of Life Estimation and Insulation Diagnosis for High Voltage Rotating Machine (고압회전기 절연진단 및 수명평가 기술현황)

  • Choi, Young-Chan;Wang, Jong-Bae;Kim, Ki-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.31-35
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced company at present motor market and are asked to set up the independent coil insulation system to accumulate insulation technology data. And to export our products at oversee market, we are asked to the evaluation of insulation performance to show our product excellence. In this study, we evaluated the insulation system of our motor, and studied the insulation diagnosis technology systematically to do site diagnosis. We are now accumulating the measured data. And also to reduce the initial insulation failure, we performed the insulation characteristic test and acquired the data to evaluate the initial soundness. We are doing the improvement of the insulation system. And also these data were used to new product development as very useful data, also will be used in the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result, we were able to get our product reliability.

  • PDF

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.