• Title/Summary/Keyword: factor of transition

Search Result 664, Processing Time 0.039 seconds

A Zero-voltage-transition PFC Circuit Based on IC UC3855

  • Shi, Lisheng;Chen, Limin;Chen, Baojiang
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.50-55
    • /
    • 1998
  • This paper introduces the advantages of zero voltage transition(ZVT) boost converter for power factor correction and analyzes the control method of ZVT with IC UC3855. Practical design issues which include the components selection and design procedure are discussed. The experimental results are given.

  • PDF

A Study on the Application of Extension Method in Railway Transition Curved Zone Considering Field Status (지형여건을 고려한 철도 완화곡선 연장방법의 적용성에 관한 연구)

  • Jeong Eui Hwan
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.4
    • /
    • pp.391-400
    • /
    • 2004
  • Railway curved zone have crucial effects on the speed of train. Length of transition curve is one of the important factor for alignment compatibility estimation in this sections, this value is decided by running speed and Cant. In this study, the extension method of transition curve is evaluated, based on the alignment of Jang Hang-Line, investigated field conditions of the sections in the curves exist. This research result show that changing of transition curve was proved by necessary to approximately two thirds of the curved sections, and method of fixing central point of track centerline and changing radius of curvature minimize the maximum shift in track centerline and deviation of radius, and also may be effective method for alignment suitability and speed up in case overall improvement is difficult.

A Study on Transition Process and factor of Exhibition Design - Based on the Exhibition's Transition in the Independence Hall - (전시디자인의 변천과정과 요인에 관한 연구 - 독립기념관의 시기별 전시변화를 중심으로 -)

  • Kwon, Soon-Kwan
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.265-272
    • /
    • 2006
  • Traditionally exhibition design as been restricted to architectural, interior, and lighting design, but recently it has begun to overlap into environmental, performance, and installation art. Exhibition design also increasingly involves the application of film, fashion, and the new media. In the past, exhibits were arranged and displayed for the visitor to view directly, but with the development of more effective exhibit media a connection has been created between the exhibit and the visitor. However exhibition design has reached the limits of continuous growth without background theory, when now it must take Into consideration the museum's activation and the importance of the exhibition's design. Exhibition design has developed and grown rapidly since the Taejeon Expo in 1993, but it is a difficult development without a theoretical structure. The flow of exhibition design must be systemized, as the systemization of the transition process of exhibition design has not yet been achieved. This study aims to present an arrangement of exhibition design flow, and to investigate the variation factors in the transition process of exhibition design and exhibit medium development, based on the 18 year history of the Independence Hall that introduced the first systematic planning of an exhibition in 1987.

Intrinsic and Thermodynamic Effects on the Structure and Energy of the S$_N$2 Transition State$^*$

  • Lee, Ik-Choon;Seo, Heon-Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.6
    • /
    • pp.448-453
    • /
    • 1986
  • Two contributions to the activation barrier of the $S_N2$ reaction, intrinsic and thermodynamic, are discussed in connection with the predictive power of various rate-equilibrium relationships. It has been shown that the PES models can only give correct predictions of changes in structure and energy of the transition state if the activation barrier is dictated by the thermodynamic factor. We concluded that the identity and dissociative $S_N2$ reactions are dominated by the intrinsic component while associative $S_N2$ reactions are predominantly of thermodynamic controlled. Thus in the former cases, the PES models fail, whereas in the latter cases predictions based on the intrinsic factor, the quantum mechanical models, fail. Finally in a general case of equal contributions by thermodynamic and intrinsic factors, the $SN_2$ reaction proceeds by a synchronous process with zero net charge on the reaction center, for which predictions of substituent effects will be the same as for the intrinsic control case.

Transport Behaviour of Electroactive Species in Ionic Compounds: A Focus on Li Diffusion through Transition Metal Oxide in Current Flowing Condition

  • Lee, Sung-Jai;Pyun, Su-Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • This article reviewed transport behaviours of electroactive species in ionic compounds, focusing on chemical diffusion of Li through the transition metal oxide in a current flowing condition. For this purpose, a distinction has been first briefly made between migration and diffusion with respect to current, driving force and charge of electroactive species considered. Then, the equations for chemical diffusion are derived theoretically in open-circuit and current flowing conditions. Finally, the experimental methods such as ac impedance spectroscopy and current (potential) transient techniques are described in details for characterising chemical diffusion. In addition, the role of the thermodynamic enhancement factor in chemical diffusion is discussed.

Thermo-Flow Analysis of Offset-Strip Fins according to Prandtl Number (Prandtl 수에 따른 옵셋 스트립 핀에서의 열 및 유동 분석)

  • Joo, Youn-Sik;Kong, Dong-Hyun;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.340-346
    • /
    • 2009
  • This paper numerically investigates thermo-flow characteristics of offset strip fins to obtain a correlation between heat transfer and pressure drop. The flow was divided into three regimes, i.e. laminar, transition and turbulent. The predicted j and f values from the SST k-$\omega$ turbulence model agreed with previous correlations with the error less than 20% in transition and turbulent regimes. Heat transfer and pressure drop were predicted by varying Prandtl number from 0.5 to 40. The Prandtl number showed little effects on pressure drop but had great effect on the heat transfer characteristics. An overall correlation to predict j was suggested by incorporating the effect of Pr and a new j correlation was suggested for each Pr.

Thermo-Flow Analysis of Offset-strip fins according to Prandtl Number (Plandtl 수에 따른 옵셋 스트립핀에서의 열 및 유동 분석)

  • Joo, Youn-Sik;Kim, Min-Soo;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.233-238
    • /
    • 2008
  • This paper numerically investigates thermo-flow characteristics of offset strip fins to obtain a correlation between heat transfer and pressure drop. The flow was divided into three regimes, i.e. laminar, transition and turbulent. The predicted j and f values from the SST k-$\omega$ turbulence model agreed with previous correlations with the error less than 20% in transition and turbulent regimes. Heat transfer and pressure drop were predicted by varying Prandtl number from 0.5 to 40. The Prandtl number showed little effects on pressure drop but had great effect on the heat transfer characteristics. An overall correlation to predict j was suggested by incorporating the effect of Pr and a new j correlation was suggested for each Pr.

  • PDF

Maximum Allowable $RT_{NDT}$ of Nuclear Reactor Vessel for Pressurized Thermal Shock Accident (가압열충격 사고에 대한 원자로 용기의 최대 허용 기준무연성천이온도)

  • 정명조;박윤원;송선호
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.153-160
    • /
    • 1998
  • A small break loss of coolant accident is postulated as a pressurized thermal shock accident in this study. From the temperature and pressure histories of coolant, distributions of the temperature and stress in a vessel wall are analytically calculated. The stress intensity factor and fracture toughness of the vessel wall are determined at the crack tip using the ASME code method and they are compared to check if cracking is expected to occur during the transient postulated. The maximum allowable reference nil-ductility transition temperatures are determined for various crack sizes and the results are discussed.

  • PDF

Investigation of Pressure Drop for a Pseudo-plastic Fluid Flow in Isosceles Triangle Pipes (이등변삼각형 단면을 갖는 파이프 내의 Pseudo-Plastic 유체유동에 대한 압력강하의 연구)

  • Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.30-35
    • /
    • 2009
  • Numerical Calculations for dimensionless pressure drop (friction factor times Reynolds number) have been obtained for fully developed laminar flow of MPL(Modified Power Law) fluid in isosceles triangle pipes. The solutions are valid for Pseudoplastic fluids over a wide range from Newtonian behavior at low shear rates through transition region to power law behavior at higher shear rates. The analysis identified a dimensionless shear rate parameter which for a given set of operating conditions specifies where in the shear rate range a particular system is operating, i.e., Newtonian, transition or power law region. The numerical calculation data of the dimensionless pressure drop for the Newtonian and power law regions are compared with previously published asymptotic results presenting within 0.16 % in Newtonian region and 2.98 % in power law region.

  • PDF

Fuzzy-Bayes Fault Isolator Design for BLDC Motor Fault Diagnosis

  • Suh, Suhk-Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.3
    • /
    • pp.354-361
    • /
    • 2004
  • To improve fault isolation performance of the Bayes isolator, this paper proposes the Fuzzy-Bayes isolator, which uses the Fuzzy-Bayes classifier as a fault isolator. The Fuzzy-Bayes classifier is composed of the Bayes classifier and weighting factor, which is determined by fuzzy inference logic. The Mahalanobis distance derivative is mapped to the weighting factor by fuzzy inference logic. The Fuzzy-Bayes fault isolator is designed for the BLDC motor fault diagnosis system. Fault isolation performance is evaluated by the experiments. The research results indicate that the Fuzzy-Bayes fault isolator improves fault isolation performance and that it can reduce the transition region chattering that is occurred when the fault is injected. In the experiment, chattering is reduced by about half that of the Bayes classifier's.