• Title/Summary/Keyword: factor level

Search Result 9,523, Processing Time 0.034 seconds

The Overall Investigation of Steel Fiber Strengthening Factor in Shear (전단에 대한 강섬유 보강계수의 종합적 고찰)

  • Lee, Hyun-Ho;Kwon, Yeong-Ho;Lee, Hwa-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.251-254
    • /
    • 2005
  • This study will have to define the shear strengthening effects of steel fiber in beam and column levels, as well as to suggest estimation method of maximum shear capacity of structural members. From review of literature surveys and perform structural member test results, following conclusion can be made; In beam level, steel fiber strengthening factor is suggested from the tensile splitting test results and beam test results. After suggesting shear capacity of beam without stirrups and beam with stirrups by proposed steel fiber strengthening factor, proposed equation is possible to evaluate the shear capacity of beam. In column level, with column test results and proposed steel fiber strengthening factor, shear capacity equation of steel fiber reinforced concrete in column is suggested.

  • PDF

The Effects of Residents' Perceptions of Tourism Impact and Conflicts on Residents' Participation in Rural Tourism Village (농촌관광마을사업에 대한 관광영향 지각 및 갈등이 주민참여에 미치는 영향)

  • Joo, Young-Min;Park, Duk-Byeong
    • Journal of Agricultural Extension & Community Development
    • /
    • v.15 no.4
    • /
    • pp.577-597
    • /
    • 2008
  • The purpose of this study is to examine the effects of residents' perceptions of tourism impact and conflicts on residents' participation in rural tourism village. Method of analysis involves factor analysis and regression analysis in this study. In order to measure the level of perception, three factors(economic benefits, social benefits, social and environmental cost) are derived from the factor analysis. And also in order to measure the level of conflict, two factor(openness of information, leading of operation) are derive from the factor analysis. The result of regression analysis indicate that perceived economic benefits and social benefits are rather greater impacts on residents' participation than social and environmental cost, and also openness of information is rather greater impacts on residents' participation than leading of operation.

  • PDF

A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator (PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발)

  • Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.

Orthognathic surgery in a patient with Factor VII deficiency: A Case Report (응고인자 VII 부족 환자에서의 악교정 수술: 증례보고)

  • Baek, Rong Min;Oh, Myung June;Lee, Sang Woo
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.93-95
    • /
    • 2009
  • Purpose: Congenital factor VII (FVII) deficiency is a rare bleeding disorder and surgery can cause excessive bleeding due to an extrinsic pathway problem. It can be diagnosed by increased PT and decreased FVII level in coagulation test. Symptom varies according to the level of FVII, but it is essential to prevent intraoperative excessive bleeding. Methods: In this report, we described the orthognatic surgery experience in a mandibular prognathism patient with congenital FVII deficiency, in which recombinant activated factor VII (rFVIIa) was used to manage the bleeding. Rsults: We could get a successful result without any complication and there was minimal intraoperative bleeding. Conclusion: The orthognathic surgery could therefore be safely performed in patients with congenital factor VII deficiency using rFVIIa.

Design of Single-Stage AC/DC Converter with High Efficiency and High Power Factor for Low Power Level Applications

  • Lee, Jun-Young;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.123-131
    • /
    • 1997
  • Design of single stage AC/DC converter with high power factor for low power level applications is proposed. The proposed converter gives the good power factor correction, low line current harmonic distortions, and tight output voltage regulations. This converter also has a high efficiency by employing an active clamp method and synchronous rectifiers. To verify the performances of the proposed converter, a 90W-converter has been designed. The modelling of this proposed converter is power formed using an averaging technique and based on this model a detailed analysis is carried out. This prototype meets the IEC555-2 requirements satisfactorily with nearly unity power factor and high efficiency.

  • PDF

Power Comparison in a Balanced Factorial Design with a Nested Factor

  • Choi, Young-Hun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.4
    • /
    • pp.1059-1071
    • /
    • 2008
  • In a balanced factorial design with a nested factor where crossed factors as well as a nested factor exist simultaneously, powers of the rank transformed FR statistic for testing the main, nested and interaction effects are superior to those of the parametric F statistic. In heavy tailed distributions such as exponential and double exponential distributions, powers of the FR statistic show much higher level than those of the F statistic. Further powers of the F and FR statistic for testing the main effect show the highest level in an absolute size as compared with powers of the F and FR statistic for testing the nested and interaction effects. However powers of the FR statistic for testing the nested and interaction effects rather than the main effect are greater in a relative size than powers of F statistic for the all population distributions.

  • PDF

A Study on the Internal Service Quality on the Internal Customer Satisfaction and the Business Performance (내부서비스품질이 고객만족과 기업성과에 미치는 영향에 관한 연구)

  • Kim Sun-Jun
    • Management & Information Systems Review
    • /
    • v.15
    • /
    • pp.147-164
    • /
    • 2004
  • The purpose of this paper is on employees as internal customers and the critical role this group plays in the delivery of quality results. The set up of research model for verification was as follows. The research model was drawn as internal service quality level $\Rightarrow$ internal customer satisfaction $\Rightarrow$ enterprise outcome. Then, two hypotheses were established to the research model. Through the factor analysis and multiple regression analysis, the results are as follows. First, internal service quality level turned out to be affected indirectly through internal customers' satisfaction rather than a direct factor to affect the enterprise outcome. Second, internal customers' satisfaction was proved to be the most important factor for the enterprise outcome as ti was the intimate factor precedent to the enterprise outcome. However, there could be a variation of response according to the personal circumstances of respondents since the respondents were from different enterprises and consisted various job positions and age group. Namely it included a limitation of rather unaccurate resulting values because the transverse methods were performed for convenience though it needed a longitudinal research to accomplish the general purpose of this study.

  • PDF

Dietary Behaviors and Perceived Stress of University Students (대학생의 식생활태도와 스트레스에 관한 조사)

  • Oh, Hae-Sook;Kim, Ji-Hyang;Min, Sung-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.19 no.2
    • /
    • pp.158-169
    • /
    • 2004
  • This study was performed in order to investigate to dietary behavior, perceived stress level and their correlations for University students. Dietry behavior of 72% subjects was poor and only 1.8% was good. The dietary behavior of subjects was correlated with their residence type. The overage stress point was $1.76{\pm}0.53$ and female students was more stressed than male. Stress elevate the food uptakes and digestion disorder in female students. 12 Factors of stress was analyzed in University students, identification, study, friends and off-school activity related factors were more influenced in female students and health related factor was dominant in male. The subjects who more stressed in factor of religion and around people were preferred salty taste. Study, friends, health related stress factor effect to digestion and food uptake level. Religion, boy or girl friends and sex related stress factor effect to alcohol uptake

A 13 Week Subcutaneous Toxicity Study of Recombinant Human Epidermal Growth Factor (DWP401) in Mice (Recombinant Human Epidermal Growth Factor (DWP401)의 마우스를 이용한 피하투여 아급성독성시험)

  • 송시환;강부현;신천철;김희연;강진석;심점순;한상섭;노정구
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.138-147
    • /
    • 1996
  • DWP401, a recombinant human epidermal growth factor, was subcutaneously administered to ICR mice at the dose levels of 0, 0.04, 0.2 and 1.0 mg/kg/day (15rats/sex/group) in order to evaluate the subchronic toxicity. General observations, examinations for food and water consumption, ophthalmoscopy and urinalysis were carried out during the study. For the complete gross and microscopic examinations, 10 mice/ sex/group were sacrificed at the ends of the dosing period, and the remaining animals were sacrificed with a 5 week recovery period. Examinations for hematology and blood biochemistry were also carried out at the time of recovery period. Based on the results, it was thought that the target tissue or organs were mesothelial cell, injection site, spleen, adrenal gland, ovary and transitional epithelial cell of urinary tract, and no observed toxic level of DWP401 was 0.04 mg/kg while definite toxic dose level might be 0.2 mg/kg.

  • PDF

Comparative Study of PI, Fuzzy and Fuzzy tuned PI Controllers for Single-Phase AC-DC Three-Level Converter

  • Gnanavadivel, J;Senthil Kumar, N;Yogalakshmi, P
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.78-90
    • /
    • 2017
  • This paper presents the design of closed loop controllers operating a single-phase AC-DC three-level converter for improving power quality at AC mains. Closed loop inhibits outer voltage controller and inner current controller. Simulations of three level converter with three different voltage and current controller combinations such as PI-Hysteresis, Fuzzy-Hysteresis and Fuzzy tuned PI-Hysteresis are carried out in MATLAB/Simulink. Performance parameters such as input power factor and source current total harmonic distortion (THD) are considered for comparison of the three controller combinations. The fuzzy-tuned PI voltage controller with hysteresis current controller combination provides a better result, with a source-current THD of 0.93% and unity power factor without any source side filter for the three level converter. For load variations of 25% to 100%, a THD of less than 5% is obtained with a maximum value of only 1.67%. Finally, the fuzzy-tuned PI voltage with hysteresis controller combination is implemented in a Xilinx Spartan-6 XC6SLX25 FPGA board for experimental validation of power quality enhancement. A prototype 100 W, 0-24-48 V as output converter is considered for the testing of controller performance. A source-current THD of 1.351% is obtained in the experimental study with a power factor near unity. For load variations of 25% to 100%, the THD is found to be less than 5%, with a maximum value of only 2.698% in the experimental setup which matches with the simulation results.