• 제목/요약/키워드: facings

검색결과 34건 처리시간 0.027초

전면벽체 강성에 따른 쏘일네일링 벽체의 거동특성에 관한 실험적 고찰 (An Experimental Study on Behavior Characteristic of the Soil Nailed Wall with Facing Stillness)

  • 김홍택;강인규;권영호;조용훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.279-286
    • /
    • 2002
  • Recently, there are many attempts to expand a temporary soil nailing system into a permanent wall due to the advantage of soil nailing system, that is efficient and economic use of underground space and decreasing the total construction cost. However, the proper design approach of a permanent soil nailing system has not been proposed by now in Korea. Permanent soil nailing system which utilizes precast concrete walls for the facing of soil nailing system Is already used in many countries. In general, the cast-in-place concrete facings or rigid walls were constructed in bottom-up way after construction of soil nailing walls finished preliminarily In this paper, various laboratory model tests have been carried out to investigate the failure mode, behavior characteristics, and tensile force at nail head in each load level in respects of the variation of stiffness of the facing.

  • PDF

Controlling the Hardness and Tribological Behaviour of Non-asbestos Brake Lining Materials for Automobiles

  • Mathur, R.B.;Thiyagarajan, P.;Dhami, T.L.
    • Carbon letters
    • /
    • 제5권1호
    • /
    • pp.6-11
    • /
    • 2004
  • In spite of unparalleled combination of essential material properties for brake linings and clutch facings, replacement for asbestos is seriously called for since it is a health hazard. Once asbestos is replaced with other material then composition and properties of brake pad changes. In certain cases hardness of the material may be high enough to affect the rotor material. In this study, hardness of the brake pad has been controlled using suitable reinforcement materials like glass, carbon and Kevlar pulp. Brake pad formulations were made using CNSL (cashew net shell liquid) modified phenolic resin as a binder, graphite or cashew dust as a friction modifier and barium sulphate, talc and wollastonite as fillers. Influence of each component on the hardness value has been studied and a proper formulation has been arrived at to obtain hardness values around 35 on Scleroscopic scale. Friction and wear properties of the respective brake pad materials have been measured on a dynamometer and their performance was evaluated.

  • PDF

조립식 쏘일네일링 공법의 개발과 시험시공사례에 관한 연구 (A Study on the Development of Assembling Soil Nailing Method and Its Applications)

  • 권영호;박신영;류정수;강인규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.113-120
    • /
    • 2005
  • Soil nailing system can be mentioned to a method of supporting as the shear strength of in-situ soils is increased by passive inclusions. In the general soil nailing system, facing walls are used in two kind of a lattice concrete block or a cast in placed concrete wall. A case of lattice concrete blocks is used in slow slopes greater than 1:0.7. Also, a case of a cast in placed concrete wall is used in steep slopes less than 1:0.5. The cast in placed concrete walls are constructed to 30cm thick together with a shotcrete facing. In this study, the assembling soil nailing method as a new soil nailing system is proposed. This method is constructed assembly using precast concrete panels. Therefore ability of the construction and quality of the facings can be modified than a usual soil nailing system. Also, this method can be obtained the effects that a global slope stability increase, as precast concrete panels is put on cutting face after excavating a slope.

  • PDF

하니컴 샌드위치 Panel을 이용한 LCD/PDP생산공정용 고기능성 복합 신소재 파렛트의 최적설계 (The Optimum Design of the Light-weight Composite Pallet Plank for Assembly Line of LCD/PDP by using Honeycomb Sandwich Panel)

  • 김윤해;최병근;손진호;조영대;엄수현;우병훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.388-394
    • /
    • 2005
  • A typical honeycomb sandwich panel consists of two thin, high-strength facings bonded to a thick, light-weight core. Each component by itself is relatively weak and flexible, but when it combind in a sandwich panel they produce a structure that is stiff, strong, and lightweight. In addition to use in honeycomb sandwich panels, honeycomb is used for energy absorption, radio frequency shielding, light diffusion, and to direct air flow.Accordingly, the usage of honeycomb sandwich structure is very widely applied to the aircraft, the automobile, and marine industry, etc., because of these advantages. Generally, this honeycomb sandwich structure is manufactured by autoclave process.In this study, the honeycomb sandwich structure was produced by prepreg. To prove the suitability the honeycomb sandwich structure with prepreg, The optimum design of the skin materials and honeycomb sandwich structure were evaluated with the theory of stress analysis.

  • PDF

구조용단열패널의 정적가력과 반복가력 성능 평가 (Performance Evaluation on Static Loading and Cyclic Loading for Structural Insulated Panels)

  • 나환선;이현주;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제4권1호
    • /
    • pp.33-39
    • /
    • 2013
  • Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.

폴리머 콘크리트 샌드위치 패널의 휨에 관한 실험적 연구 (An Experimental Study on the Flexural Deflection of Sandwich Panels with Polymer Concrete Facings)

  • 함형길;이석건;연규석;이현우;이종원
    • 한국농공학회지
    • /
    • 제39권1호
    • /
    • pp.54-63
    • /
    • 1997
  • The purpose of this study is to analyse deformation properties by carrying out of flexure experimentations after fabricating polymer concrete sandwich panels which are composed of the polymer concrete in facing and expanded polystyren in cores, and to provide the basic data necessary to design, fabricate and operate the structure using these polymer concrete sandwich panels The analysed result of this study is summarized as follows. 1. The result of experiment on flexural deflection indicated that the thicker the thickness of both cores and facing of the polymer concrete sandwich panels, the smaller the deflection but the larger the ultimate shear force. In addition, it was also shown that the thicker the thickness of these cores and facing, the smaller the increasing rate of the deflection with the increase of load. 2. The breaking shape of polymer concrete sandwich panels by experiment on flexure was different according to the thickness of facing. When the facing was 5mm in thickness, it was the flexure while it was the flexure and shear failure when the facing was 5mm in thickness. As a result, it seems that the thickness of the facing has a great effect on failure. 3. There were induced not only the related formula between load, deflection and deformation according to the thickness of cores and facing on the basis of the flexure experiment, but also formula between load, horizontal displacement, Then, it seems that it will be possible to estimate the above elements by using these related formulas.

  • PDF

현장노출시험에 의한 부직포 지오텍스타일의 내후성 평가 (Weatherability Assessment of Nonwoven Geotextiles by Field Exposure Test)

  • 전한용;유승조;김영윤;변성원;이웅의
    • 한국지반신소재학회논문집
    • /
    • 제3권1호
    • /
    • pp.37-42
    • /
    • 2004
  • 보강토 옹벽시스템에서, 부직포 지오텍스타일은 블럭이 시공될 때 보강토체의 전면에 노출, 포설되어 있다. 임시구조물에 보강토 옹벽이 적용될 때 지오텍스타일은 시공기간 중 일광에 노출되게 된다. 이 기간 중, 자외선에 의해 부직포 지오텍스타일의 분해가 발생하게 된다. 따라서 현장시공의 관점에서 부직포 지오텍스타일의 자외선 저항성이 명확하게 평가되어야만 한다. 본 연구에서는 실험실 및 현장시험을 수행하여 KOESWall 시스템에 사용되는 부직포 지오텍스타일의 자외선 저항성이 평가되었고, 그 결과를 SEM 사진과 인장특성으로 나타내었다.

  • PDF

전면벽체의 강성이 Soil Nailing 시스템의 전체안정성에 미치는 영향 (Influence of Facing Stiffness on Global Stability of Soil Nailing Systems)

  • 김홍택;강인규;권영호
    • 한국지반환경공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.51-60
    • /
    • 2004
  • Soil Nailing 공법은 국내의 경우 1993년 처음으로 적용된 이후 최근에는 가시설용에서 영구용으로 확대되어 적용되고 있다. Soil Nailing 공법에 있어서 강성 전면벽체는 지반의 변형을 억제하는 역할을 하며, 인접한 건물 또는 지하구조물 등의 손상을 최소화 하기 위한 목적으로 사용되고 있다. 국내의 경우 도심지에 적용되고 있는 Soil Nailing 벽체는 지반의 이완을 최소화하기 위해 H-Pile+토류판, 쉬트파일, SCW 및 JSP 등의 흙막이 벽체와 함께 종종 사용되고 있다. 그러나 전면벽체의 강성을 고려하기 위한 적당한 설계방법에 대한 제시가 없는 실정이어서 안전측에서 벽체의 강성에 의한 구속효과를 무시하여 왔다. 본 연구에서는 Soil Nailing 벽체의 전체 안정성에 벽체의 강성이 미치는 영향을 알아보기 위해 다양한 실내모형실험이 수행되었으며, 전단강도감소기법과 같은 수치해석기법을 이용한 매개변수변화연구도 시도되었다. 매개변수변화연구에서는 전면벽체의 강성의 영향을 알아보기 위해 콘크리트 전면벽체의 두께를 변화시켰다.

  • PDF

블록식보강토옹벽의 전면 사면붕괴 사례연구 (Case Study on Global Slope Failure Case of Segmental Retaining Wall)

  • 한중근;조삼덕;정상섬;이광우;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제4권2호
    • /
    • pp.47-56
    • /
    • 2005
  • 최근 경제성, 시공성 및 수려한 외관 등의 장점을 가진 토목섬유 보강토옹벽이 점차 기존의 콘크리트옹벽을 대체해가고 있다. 또한 국토의 효율적 활용을 위해 10m이상 높이의 보강토옹벽 시공이 점차 증가하고 있다. 그러나 보강토옹벽에 대한 설계 및 시공 상의 부주의에 기인한 전면벽체의 변위 및 파손, 보강토옹벽의 붕괴 등과 같은 실폐사례들이 종종 발생하고 있다. 이러한 붕괴사례 중, 전면활동파괴가 발생된 현장사례에 대하여, 일련의 현장지반조사와 계측결과 분석을 통해 붕괴원인을 규명하고, 적절한 대책안을 제시하기 위한 연구를 수행하였다. 연구결과 본 현장 보강토옹벽의 전면 활동파괴는 강우의 침투로 인해 보강토옹벽 하부 기초지반의 지지력이 감소되어 발생한 것으로 나타났다.

  • PDF

벽식 구조체 적용을 위한 구조용단열패널 성능 평가 (Evaluation on Structural Performance of Structural Insulated Panels in Wall Application)

  • 나환선;이현주;이철희;황성욱;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.