• 제목/요약/키워드: facility standard

검색결과 917건 처리시간 0.026초

오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(II) - 차집용량과 월류오염부하 삭감목표 설정 - (Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed (II) - Establishment of Intercepting Capacity and Reduction Goal of Overflow Pollution Load -)

  • 이두진;신응배
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.557-564
    • /
    • 2005
  • The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

유비쿼터스 환경의 지능형 시설물 모니터링 기술 개발

  • 남상관;이우식;구지희;우제윤;이종국
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2004년도 추계 학술대회 논문집
    • /
    • pp.105-110
    • /
    • 2004
  • This study suggests a trial system for facility monitoring technology on ubiquitous environment. The trial system can be used for integrated various collection and sending data by bluetooth and wireless network from bridge. We used smart sensor and wireless network for it. Especially, we analyzed out all appliable technologies at monitoring part on ubiquitous environment and gave a standard spec to build the system. We wanted it as a guideline to apply ubiquitous in smart facility monitoring part.

  • PDF

AHP를 이용한 군 취사식당 기능공간 분석 (Analyzing the Functional Spaces of Military Dining Facilities Using Analytic Hierarchy Process)

  • 이승후;이현수;박문서;지세현
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.155-164
    • /
    • 2020
  • This research used Analytic Hierarchy Process(AHP) to analyze the importance and priority of functional space and evaluation factors of each functional space of the military dining facility. Dining in the military is an important factor in restoring combat power and promoting morale. The military dining facility serves as a not only for meals, but also for watching TV, education and club activities. Workers working in dining facility spend most of their work hours in dining facility, perform tasks such as cooking, dishwashing, and leftover disposal, and take breaks. As such, the military dining facility is a space where various functions are performed, and space planning should take into account these various functions when planning the building of the dining facility. However, the criteria for defense and military facilities, which are the basis for planning the space of military dining facility, are calculated only by simply analyzing the standard floor plan to match the size of the person-to. Therefore, when there is space to be reduced in the total area, there are side effects such as leaving visible table space without consideration for priority or functional space, unseen office space, and adjusting the entire area through reduction of the lounge. Accordingly, based on the priority of the space that the staff of the military dining facility considers important, this research aims to analyze the characteristics of each functional space through classification according to its unique function. This can be an indicator that can be used as a basis for future revision of the building floor area standards of the defense and military facilities standards, and it can improve usability with an efficient space plan that takes into account the characteristics of the Korean military and the satisfaction of its workers. Furthermore, efficient use of the defense budget through rational building plans can contribute to budget reduction.

현행소방시설설치기준의 분석과 개선방안에 관한 연구 (A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings)

  • 정병재;이경회
    • 한국화재소방학회논문지
    • /
    • 제4권2호
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

현행소방시설설치기준의 분석과 개선방안에 관한 연구II (Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings)

  • 정병재;이경회
    • 한국화재소방학회논문지
    • /
    • 제5권1호
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

노인주거 복지시설 거주 노인의 안전사고 영향변수 검증도구 개발 및 분석에 관한 연구 (A Study on Development and Analysis of Accident Influence Factor Verification Tools for the Elderly People in the Welfare Facilities for the Aged)

  • 유종옥;박재승
    • 한국실내디자인학회논문집
    • /
    • 제20권3호
    • /
    • pp.242-248
    • /
    • 2011
  • According to a study on the accident patterns of older people in 2006 by Korea Consumer Agency (CISS), the number of accidents of the elderly at home reached 486, and the figure has increased every year. As Korea is about to enter into the aged society, it is important to investigate the factors that cause an accident in the welfare facilities for the aged and establish the barrier-free construction standards. The accident influence factors include facility environmental, physical functional, socio demographic and socio psychological factors. In terms of the verification tools, there are Facility Evaluation Index, FIM, MMSE-K and General Feature. In terms of analysis method, in addition, there are real number, percentage, t-test, ANOVA and logistic regression. In conclusion, this paper attempts to reveal correlations among the accident influence factors using the Facility Evaluation Standards (115 items in total) for facility environmental factor, FIM (3 items) for physical functional factor, MMSE-K (6 items) for socio psychological factor and questionnaire (5 items) for socio demographic factor.

의료기관 인증제도에서 요구되는 건축계획요소에 관한 연구 - 국내 의료기관인증제도, JCI 병원인증기준을 중심으로 - (A Study on the Elements of Architectural Planning Required in Healthcare Accreditation - Focused on Korea Healthcare Accreditation, JCI Hospitals Standard -)

  • 김의현;양내원
    • 한국실내디자인학회논문집
    • /
    • 제21권2호
    • /
    • pp.223-230
    • /
    • 2012
  • These days, hospitals in Korea have great interests in healthcare accreditation. The criteria of this accreditation has been established by management, but development of the management system without facility improvement has limits. Therefore this study reclassified domestic and foreign healthcare accreditation focusing on facilities and has purpose on proposing facility elements that can be adopted in hospitals. Also, the study is relevant to the study on architecture planning of hospital according to 'Patient safety' which will be suggested in the future and has significance for establishing basis of healthcare facility planning and for improving the existing facilities. The study selected facility lists from 'healthcare accreditation' and reclassified them based on departments in the hospital. Using these lists, the study divided the hospital that has obtained 'healthcare accreditation' into departments and investigated and analyzed them. On the basis of the analysis, the study suggested facility lists involved in hand washing, waste disposal, equipment washing, quarantine, goods-movement, establishing clean/polluted area, emergency exit-way, and restricted zone.

  • PDF

용량 제약이 있는 이계층 설비 입지선정 문제의 최적화 해법 (An Optimization Algorithm for the Two-Echelon Capacitated Facility Location Problem)

  • 김은정;강동한;이경식;박성수
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2003년도 춘계공동학술대회
    • /
    • pp.137-144
    • /
    • 2003
  • We consider Two-echelon Single source Capacitated Facility Location Problem (TSCFLP). TSCFLP is a variant or Capacitated Facility Location Problem (CFLP). which has been an important issue in boa academic and industrial aspects. Given a set or possible facility locations in two echelons (warehouse / plant), a set or customers, TSCFLP is a decision problem to find a set or facility locations to open and to determine an allocation schedule that satisfies the demands or the customers and the capacity constraints or the facilities, while minimizing the overall cost. It ran be shown that TSCFLP Is strongly NP-hard For TSCFLf, few algorithms are known. which are heuristics. We propose a disaggregated version or the standard mixed integer programming formulation or TSCFLP We also provide a class or valid Inequalities Branch-and-price algorithm with rutting plane method Is used to find an optimal solution Efficient branching strategy compatible with subproblem optimization problems Is also provided. We report computational results or tests on 15 randomly generated instances.

  • PDF