Abstract

The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

Keywords

References

  1. Moffa, P.E. (1997) Control and Treatment of Combined Sewer Overfrrws, 2nd Ed.,Van Nostrand Reinhold
  2. U.S. EPA (2001) Report to Congress; Implementation and Enforcement of the Combined Sewer Overfrrw Control Policy
  3. WEF & ASCE (1994) Existing Sewer Eualuation & Rehabilitation
  4. 이두진, 신응배, 홍철의, 안세영 (2004) 합류식 하수관거 지 역에서 강우시 하수처리장 적정운영방안에 관한 연구, 한국물환경학회지. 20(2). pp.132 144
  5. 이두진, 윤현식 (2004) 건기 침입수/유입수 저감에 따른 CSOs 오염부하 삭감효과 예측, 대한토목학회논문집, 24(3B). pp.273-280
  6. 한국수도협회 (1998) 하수도시설기준
  7. 환경관리공단 (2004) 도심지 합류식하수관거 월류수 및 분류식 우수관거 우수유출오염부하기초조사 연구
  8. 환경부 (2001) 주택단지내 상수 오수발생량 원단위 산정 및 하수처리시설 소요비용 연구