• Title/Summary/Keyword: facility standard

Search Result 928, Processing Time 0.023 seconds

A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room (호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로)

  • Yoon, Hyung Jin;Han, Su Ha
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.

Development of Standard Calibration System for the Rain Gauges by Weighting Method (질량측정에 의한 우량계 표준교정시스템 개발)

  • Shin Gang-Wook;Hong Sung-Tack
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.8
    • /
    • pp.818-823
    • /
    • 2006
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the uncertainty for the rainfall intensity and obtained useful result through the proposed calibration method.

Strategy of Establishing GIS for Social Facility in Korea (한국의 사회기반시설물 GIS 구축 방안)

  • 이태식;이교선;조영준
    • Spatial Information Research
    • /
    • v.2 no.1
    • /
    • pp.27-38
    • /
    • 1994
  • Due to the rapid civilization, the need for social facilities is increasing. When these facilities controlled by the integrated facility management system (GIS), various adverse situations such as emergencies, inconvenience of the public and duplication of construction cost can be improved. In this study, the types of information for GIS which may be needed by the facility management agencies are investigated and analyzed. Based on this information, major components for the integrated facility management system including standard format of digital map, basemap scales, and basemap management methods are established.

  • PDF

The Comparative Study on the Community Consciousness and Community Facility Using Behavior of the Condominium and the National Rental Housing (공공분양과 임대 아파트 거주자들의 커뮤니티 의식과 커뮤니티 공간 이용 행태 비교 연구)

  • Park, Jae-Hyun;Kang, Soon-Joo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.156-161
    • /
    • 2009
  • This study was motivated by the fact that the current tendency of social integration in apartment complex is not fully performed its functions as a recovery from the community. The purpose of the study is to provide basic data to be useful for living environment of apartment complex, through comparative analysis of residential conditions, community consciousness, and community facility using behavior of residents in national rental housing and condominium. The results are as follows. 1) Condominium's residents have high level of community consciousness compare to the national rental's. Even though both targets were generally above the average, housing and construction standard are required to reconsider for the enhancing of community consciousness of residents. 2) To activate the use frequency of community facility, the development and operation of the community program and the community space and facilities are constantly considered in the follow-up studies. 3) The more residents have high community consciousness, the more they use the community facilities.

  • PDF

A Study on the Application of Natural Zeolite as Coagulant Aid for Effluent Quality Improvement in Private Sewage Treatment Facility (개인하수처리시설 처리수의 수질 개선을 위한 응집보조제로서의 천연제올라이트 적용에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.121-128
    • /
    • 2012
  • The purpose of this study is to solve the problem of nutrient removal due to rapid hydraulic retention time (HRT) variation in small size private sewage treatment facility and to have better effluent quality by using natural zeolite as a coagulant aid. The experiments were conducted by applying different conditions of HRT, coagulant, and zeolite dosages. As an experimental result, $TBOD_{5}$, TSS, and TP removal efficiencies were 64.9%, 94.5%, and 98.8% at co-injection with zeolite. Overall removal efficiencies of $TBOD_{5}$, TSS, and TP have improved 15.7, 28.7, 6.1%, respectively. This result shows that zeolite addition could improve flocculation, increase setting velocity, and thus have better treatment. Therefore the use of zeolite as a coagulant aid can be useful in small size private sewage treatment facility, where especially extra nutrient removal is required to meet the legal standard for discharge.

A Study on the Definition of the Educational Facility Maintenance (교육시설물 유지관리 업무규명에 관한 연구)

  • Shon Woo-Kyung;Kim Jang-Young;Han Choong-Hee;Kim Sun-kuk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.567-570
    • /
    • 2002
  • our country school construction from 1990 year middle the facility expension for the improvement or education environment and the maintenance expense of various conservative construction for old education facilities is increasing. It accomplishes the each subject wild for business which maintains the training facility enterprise to be, the minute paragraph of information and deficient standard of information. It brings about the duplication investment a waste of the revenue source which is limited. Occurrence information which it follows consequently in business process and requirement must clear. We the maintenance phase of the education facilities understand, problem point and obstacle VIP analysis it leads it presents it does analyze. The improvement process model which leads a hereafter function for obstacle VIP extraction and information model construction must be accomplished.

  • PDF

A Case Study of Spatial Composition of Elderly Skilled Nursing Facility - Focused on 5 facilities of Jeonbuk Province of Korea - (노인 전문요양시설의 공간구성에 관한 연구 - 전라북도 소재 5개 시설을 중심으로 -)

  • 이민아;유옥순
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The purpose of this study was to analyze spatial composition of elderly skilled nursing facility and to provide basic information for setting up the detail facility architectural guidelines. The results of the study were following: the residential spaces of the facilities in this study were more or less overcrowded since their capacity were more than 5 elderly residents. The dimensions of some residential spaces did not even come up to the standard of elderly welfare law in force. On the other hand, the facilities had a tendency to use a space with multiple purposes or to allocate a space but to leave it with no use. Moreover comparing with the 1st floor, which was mainly for the staffs and had enough space to spare, the upper floor which was for the elderly residents, was crowded with nursing staffs and elderly residents and had densely closed residential and public spaces. For the problem solving, law and regulation modification is needed according to the case study about the usage and using frequency of each facility space. And the crowded area for the elderly residents could be enlarged through the reduction(or combination) of the rarely used spaces and moving a few residential spaces into the 1st floor.

A Study on Methodology of Assessment for Hydrogen Explosion in Hydrogen Production Facility (수소생산시설에서의 수소폭발의 안전성평가 방법론 연구)

  • Jae, Moo-Sung;Jun, Gun-Hyo;Lee, Hyun-Woo;Lee, Won-Jae;Han, Seok-Jung
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.3
    • /
    • pp.239-247
    • /
    • 2008
  • Hydrogen production facility using very high temperature gas cooled reactor lies in situation of high temperature and corrosion which makes hydrogen release easily. In that case of hydrogen release, there lies a danger of explosion. However, from the point of thermal-hydraulics view, the long distance of them makes lower efficiency result. In this study, therefore, outlines of hydrogen production using nuclear energy are researched. Several methods for analyzing the effects of hydrogen explosion upon high temperature gas cooled reactor are reviewed. Reliability physics model which is appropriate for assessment is used. Using this model, leakage probability, rupture probability and structure failure probability of very high temperature gas cooled reactor are evaluated and classified by detonation volume and distance. Also based on standard safety criteria which is value of $1{\times}10^{-6}$, safety distance between the very high temperature gas cooled reactor and the hydrogen production facility is calculated.

A Study on the Waste Volume Calculation for Efficient Volume Monitoring in a Landfill Facility (매립장의 효율적인 체적 모니터링을 위한 체적 계산 방법에 대한 연구)

  • Lee, Young Dae;Cho, Sung Youn
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.153-159
    • /
    • 2012
  • For the enhancement of civilization of a city, the standard landfill facility is needed for the efficient, and computerized management. In this paper, we proposed the waste volume calculation method using the point cloud of the surface of three dimensional object based on stereo camera measurement. This computes the quantity of waste volume for continuos monitoring. It helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, it can be used for the basis of general algorithm of three dimensional object.

BAT-AEL Calculation in Waste Incineration Facility (폐기물 소각시설 최적가용기법 연계배출수준 (BAT-AEL) 설정)

  • Shin, Sujeong;Park, Jae-Hong;Lee, DaeGyun;Kim, Dai-Gon;Bae, YeonJoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.144-155
    • /
    • 2018
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In addition, if the facility with BAT works normally, the pollutant emission is offered with the range of lower limit to upper limit. This study analyzed the overview of Best Available Techniques-Associated Emission Levels (BAT-AEL), and its setting procedure and method, and then suggested the BAT-AEL of a waste incineration facility. In comparative analysis on Emission Limit Values (ELVs) of EU, this study tries to propose improvement matters and development directions if the relevant standard is revised.