• 제목/요약/키워드: facility standard

검색결과 917건 처리시간 0.029초

의료기관 인증제도에서 요구되는 건축계획요소에 관한 연구 - 국내 의료기관인증제도, JCI 병원인증기준을 중심으로 - (A Study on the Elements of Architectural Planning Required in Healthcare Accreditation - Focused on Korea Healthcare Accreditation, JCI Hospitals Standard -)

  • 김의현;양내원
    • 한국실내디자인학회논문집
    • /
    • 제21권2호
    • /
    • pp.223-230
    • /
    • 2012
  • These days, hospitals in Korea have great interests in healthcare accreditation. The criteria of this accreditation has been established by management, but development of the management system without facility improvement has limits. Therefore this study reclassified domestic and foreign healthcare accreditation focusing on facilities and has purpose on proposing facility elements that can be adopted in hospitals. Also, the study is relevant to the study on architecture planning of hospital according to 'Patient safety' which will be suggested in the future and has significance for establishing basis of healthcare facility planning and for improving the existing facilities. The study selected facility lists from 'healthcare accreditation' and reclassified them based on departments in the hospital. Using these lists, the study divided the hospital that has obtained 'healthcare accreditation' into departments and investigated and analyzed them. On the basis of the analysis, the study suggested facility lists involved in hand washing, waste disposal, equipment washing, quarantine, goods-movement, establishing clean/polluted area, emergency exit-way, and restricted zone.

  • PDF

용량 제약이 있는 이계층 설비 입지선정 문제의 최적화 해법 (An Optimization Algorithm for the Two-Echelon Capacitated Facility Location Problem)

  • 김은정;강동한;이경식;박성수
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2003년도 춘계공동학술대회
    • /
    • pp.137-144
    • /
    • 2003
  • We consider Two-echelon Single source Capacitated Facility Location Problem (TSCFLP). TSCFLP is a variant or Capacitated Facility Location Problem (CFLP). which has been an important issue in boa academic and industrial aspects. Given a set or possible facility locations in two echelons (warehouse / plant), a set or customers, TSCFLP is a decision problem to find a set or facility locations to open and to determine an allocation schedule that satisfies the demands or the customers and the capacity constraints or the facilities, while minimizing the overall cost. It ran be shown that TSCFLP Is strongly NP-hard For TSCFLf, few algorithms are known. which are heuristics. We propose a disaggregated version or the standard mixed integer programming formulation or TSCFLP We also provide a class or valid Inequalities Branch-and-price algorithm with rutting plane method Is used to find an optimal solution Efficient branching strategy compatible with subproblem optimization problems Is also provided. We report computational results or tests on 15 randomly generated instances.

  • PDF

CFD를 이용한 쓰레기 처리시설의 악취확산 예측에 관한 연구 (A Study on Odor Dispersion Prediction of Waste Treatment Facilities Using CFD)

  • 경서경;김공숙;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.342-349
    • /
    • 2009
  • The purpose of this study is to estimate efficiently an odor dispersion from waste treatment facility for a crematory and a neighborhood facility, then propose planning, a location of an opening or the arrangement of the trees. Hence, offer a comfortable environment for a resident. For this, first the research data about estimating odor dispersion from waste treatment facility and odor are analyzed, then research an ingredient, characteristic, a direct effect for human and a method of measurement. Second, with on-site survey, check odorimetry and the source of odor dispersion, then apply this to the boundary condition of CFD simulation. Third, analyse by the hour for the 2008 standard weather data of Cheon-an, then apply summer data that odor dispersion is active, winter data relatively slow and an annual mean velocity and wind to the simulation. Even if a crematory and neighborhood facility located on south and north from waste treatment facility are at the low rate, the south and north wind will be applied to the simulation. Fourth, with CFD simulation result, predict an odor dispersion, then propose a solution which is considered an odor dispersion, a location of an opening and the arrangement of the trees. Consequently, this study will have an effect on an environment of a resident.

  • PDF

XML 스키마를 위한 갱신 기능 (Update Facility for XML Schema)

  • 이기준;황수찬
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제16권3호
    • /
    • pp.324-330
    • /
    • 2010
  • XML 스키마는 XML 문서의 자료를 구조화하고 검증하기 위한 효율적 수단으로 사용되고 있다. W3C는 XML 데이터의 검색과 갱신을 위한 표준으로 XQuery와 XQuery Update Facility를 발표하였으나 XML 스키마 자체에 대한 갱신 기능은 아직 제시하지 않고 있으며 스키마를 수정하기 위해서는 XML 스키마 파일을 편집기 등을 이용하여 직접 수정하여야 한다. 그러나 XML 스키마에 대한 직접적인 수정 방법은 사용자의 불법적 갱신을 방지할 수 없고, 데이터베이스에 저장된 XML 스키마에 대한 적용의 어려움, 스키마 분석의 시간 소모, 문법적 오류의 발생 가능성 등의 문제가 있다. 따라서 본 논문에서는 명령어를 이용하여 XML 스키마에 대한 생성, 수정, 삭제를 가능토록 하는 XML 스키마 갱신 기능을 제안하고자 한다.

Design and fabrication of beam dumps at the µSR facility of RAON for high-energy proton absorption

  • Jae Chang Kim;Jae Young Jeong;Kihong Pak;Yong Hyun Kim;Junesic Park;Ju Hahn Lee;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3692-3699
    • /
    • 2023
  • The Rare isotope Accelerator complex for ON-line experiments in Korea houses several accelerator complexes. Among them, the µSR facility will be initially equipped with a 600 MeV and 100 kW proton beam to generate surface muons, and will be upgraded to 400 kW with the same energy. Accelerated proton beams lose approximately 20% of the power at the target, and the remaining power is concentrated in the beam direction. Therefore, to ensure safe operation of the facility, concentrated protons must be distributed and absorbed at the beam dump. Additionally, effective dose levels must be lower than the legal standard, and the beam dumps used at 100 kW should be reused at 400 kW to minimize the generation of radioactive waste. In this study, we introduce a tailored method for designing beam dumps based on the characteristics of the µSR facility. To optimize the geometry, the absorbed power and effective dose were calculated using the MCNP6 code. The temperature and stress were determined using the ANSYS Mechanical code. Thus, the beam dump design consists of six structures when operated at 100 kW, and a 400 kW beam dump consisting of 24 structures was developed by reusing the 100 kW beam dump.

간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구 (Research on composting of sewage sludge using dryer facility with indirect heating system)

  • 백선재;한인섭;최익훈;강성효;홍성민
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구 (A Study on the Fire Risk of ESS through Fire Status and Field Investigation)

  • 박광묵;김재현;박진영;방선배
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.91-99
    • /
    • 2018
  • 최근 국내 ESS의 보급이 늘어나면서 화재사고 또한 발생하고 있다. 2018년 7월까지 총 7건이 발생하였다. 7건 모두 리튬이온배터리로 구성된 ESS 시스템으로 발화 이후 자동소화설비 또는 소방서에 의해 진화되지 못하고 전소되었다. 본 논문에서는 최근 발생한 ESS 화재현황 및 현장조사를 바탕으로 ESS 화재의 특징을 파악하고 발화원인을 환경적, 전기적, 열적 요인으로 나누어 분석하였다. 그 결과 ESS 화재가 시스템의 설치환경과 상관관계가 있음을 파악하였다. 국내외 리튬이온배터리 시험표준 및 ESS 시설기준 조사에서는 국내외 동향 및 차이점을 파악하였다. 화재현황 및 현장조사, 국내외 시설기준 조사 등을 토대로 ESS 화재 시 화재 확산을 방지하고 예방하기 위한 대책을 제시하였다.

거주 후 평가를 통한 국가지정 입원치료병상 시설 개선 방향 도출에 관한 연구 (A Study on the direction for Facility Improvement of Nationally Designated Negative Pressure Isolation Ward through Post Occupancy Evaluation)

  • 정다운;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제27권3호
    • /
    • pp.39-49
    • /
    • 2021
  • Purpose: The negative pressure isolation ward is a key facility in preparedness and response to infectious diseases. For the sustainable operation of the facility, appropriate facility improvement is required. The experience of medical staff responding to infectious diseases in the COVID-19 pandemic provides effective informations for facility planning. Methods: The post occupancy evaluation (POE) was conducted by interviewing medical staff who is working on Nationally designated negative pressure isolation ward in general hospital. Floor plan analysis was conducted before field surveys for identifying facility characteristic and spatial composition. After that, field surveys were conducted at 3 hospitals, and interviews and fieldwork were conducted together. Results: It is necessary to increase the standard size of ward area from 15m2 to 20m2. The size of the doffing room has to be planned for accommodation of two or more people. Equipment storage, clean storage and waste storage also should be properly planned. There were almost no problems with the circulation in the ward. There was not enough space for medical staff. Implications: For a sustainable and safe negative pressure isolation ward planning, it is necessary to exploit learning from the medical staffs who have many experiences of coping with infectious diseases.

제조설비 데이터 수집 표준을 이용한 설비 데이터 시각화에 대한 연구 (A Study on the Visualization of Facility Data Using Manufacturing Data Collection Standard)

  • 고동범;박정민
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권3호
    • /
    • pp.159-166
    • /
    • 2018
  • 본 논문은 스마트 공자의 모니터링을 위한 제조설비 시각화 시스템을 소개한다. 최근 기술 발달의 가속화와 제 4 차 산업혁명, Industry 4.0등과 같은 용어가 등장함에 따라 기존 제조공장의 스마트화를 위한 기술들이 조명되고 있다. 제조공장을 실시간으로 모니터링 함으로써 생산성 향상 및 의사결정의 도움을 줄 수 있는 생산관리 시스템은 스마트 팩토리를 위한 중용한 기술 중 하나가 되며, 더 정확한 모니터링 및 응용 기술을 위한 디지털 트윈 기술의 적용 또한 중요한 이슈가 되고 있다. 그러나 디지털 트윈 구현을 위해서는 여러 제조사의 설비 데이터를 통합할 수 있는 통합 인프라가 필요하다. 따라서 본 논문은 이기종의 설비 데이터 수집 및 모니터링을 위한 국제 표준 프로토콜 기반의 데이터 수집 시스템을 활용해 설비의 실시간 정보를 확인할 수 있는 시각화 프로그램을 설계하고 개발한다. 이를 통해 하나의 공장에서 여러 제조사의 설비 데이터들을 통합하고 실시간으로 확인 할 수 있도록 한다.

Improvement of Shade Structures for Ginseng Cultivation

  • Kim, Seoung Hee;Kim, Min Young;Lee, Sang Bong;Jang, In Bea;Lee, Kyou Seung
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.270-278
    • /
    • 2013
  • Purpose: Using agricultural machinery was not easy in the conventional shading structure, specified as a standard facility by standard cultivation methods for ginseng. Thus, this study designed the new types of facility allowing machine access by modifying the conventional type. Methods: Two types of facility (i.e. wide roof type and long & short roof type) were designed and installed in an experimental site to evaluate its growing environments and applicability of riding-type cultivator. Results: From the results of incoming light measurement, all three types (i.e. two new types and a conventional type) of shading structures blocked the incoming light after 9:00 am. The temperature distribution inside the new types was similar with the one in the conventional type, so the growth of ginseng was in good condition in all three types of facility. The riding-type cultivator was operated well with the low speed first gear of 0.13 m/s in the new types. However, a long & short typed roof needs to be raised 18 cm height in order to use the cultivator. Conclusions: With the results of this study, the new types of roof can be used in the ginseng farm in that they satisfied the growing environments for ginseng and the needs for agricultural mechanization.