• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.024 seconds

A Study on Sanitation Management Recognition and Employee Performance in the Kitchens and Food and Beverage Departments of Deluxe Hotels (특급 호텔 조리 식음료 종사자의 위생 관리 인지도 및 수행도에 관한 연구)

  • Kim, Bo-Ra-Mi;Lee, Ra-Rae;Lee, Mi-Ho;Lee, Sung-Jae;Cho, Yu-Jin;Yoon, Hyun-Joo;Yoon, Ki-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.17 no.6
    • /
    • pp.943-956
    • /
    • 2007
  • This study was conducted to assess the current status of food safety/sanitation training programs, including HACCP, for kitchen and hall employees at major hotels, as well as how differently the training can affect the employees' recognition and performance of food safety/sanitation management in areas related to the facility, food, and their personal hygiene. A questionnaire for assessing the recognition and performance of sanitation management was developed and distributed to 430 employees currently working in the kitchens and halls of 5 hotels located in Seoul, Korea. A total of 324 questionnaires (kitchen: 138, hall: 186) were subjected to frequency analysis, chi-square tests, one way ANOVA, and Pearson correlation analysis using SPSS/windows software. Ninety-one percent of the respondents had received food safety/sanitation training, which was conducted by a hygienist or a cook once a month. However, only 55% of the respondents had HACCP training. The employees that did not have HACCP training had lower recognition scores than those who had HACCP training, especially in the washing procedures for tablewares, handwashing tools, cross contamination, reheating, and HACCP definitions. Trained, full-time employees received significantly higher recognition and performance scores than untrained, contract, or part-time employees. Significant differences in the recognition and performance scores were found among the employees of the 5 different hotels, indicating various levels for the outcome of their sanitation training. In addition, Pearson's correlation analysis confirmed that the recognition and performance scores were significantly correlated (r=0.473, p<.001). This study indicates that hotel foodservice employees must receive systematic food safety/sanitation training, including HACCP, which provides the foundation for safe foodservice operations.

  • PDF

A Study of Safety Evaluation Based on the Road closure Simulation, and on the Isolation Risk in Times of Disaster (재해시 위험가능성과 도로폐쇄시뮬레이션에 의한 방재안전성에 관한 연구 - 일본 오이타현 사이키시를 대상으로 -)

  • Kim, Daeill;Park, Sungchan;Go, Jooyeon;Yeom, Chunho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.84-93
    • /
    • 2020
  • In recent years, the scale of damage from disasters such as earthquakes and large-scale fires and floods that are occurring in Korea is increasing. Accordingly, interest in urban disaster prevention that combines living infrastructure such as roads and parks is boosting, and it is urgent to prepare measures to reduce the damage scale of local cities. The purpose of this study is to derive implications for disaster prevention measures in areas where disaster prevention safety of local cities is weak through examples of disaster prevention safety of local cities in case of disaster. To this end, this study analyzed the regional characteristics, current status, and disaster prevention problems of regional cities in Japan, and selected disaster-vulnerable areas, and considered the distance relationship between disaster prevention bases through road network analysis. In addition, road closure simulation using ArcGIS Network Analyst was conducted to analyze disaster prevention safety in the area. As a result, the situation of the village which has a high possibility of isolation by natural disasters was grasped in advance. Through this, the suburbs confirmed the necessity of supplementing the disaster prevention function through transportation maintenance such as forest roads, and it was found that the city needs to prepare a risk management system. Furthermore, this study suggests the need for research on areas with a high possibility of isolation, especially in areas where disaster prevention functions are weak in local cities in case of disaster, and shows countermeasures for disaster prevention measures and resident education.

Case Study on Advanced Fire and Explosion Index (화재폭발지수 개선에 대한 사례 연구)

  • Na, Gun Moon;Seoe, Jae Min;Lee, Mi Jeong;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.78-84
    • /
    • 2020
  • The F&EI technique is one of the risk assessments with many advantages. It can save time and effort compared to quantitative risk assessment (QRA). By using the evaluation result of this technique, it is possible to check the effectiveness of the investment cost. In addition, a relative risk ranking can be created and used to establish the facility management cycle and to prioritize investment. However, evaluating the target process can be evaluated more than the actual risk since the LCCF, a loss prevention measure, is too limited. In addition, calculating premiums via this method can result in excessive premiums, making it difficult to evaluate the risk precisely. Therefore, new safety guard was added to the LCCF of the F&EI risk assessment with reference to HAZOP and LOPA techniques. Newly added LCCFs are Deflagration arrester, Check valve, SIS, and Vacuum beaker, etc. As a case study, F&EI risk assessment was performed on Acetone storage tank of a API (Active pharmaceutical ingredient) plant to compare actual MPPD. The estimated loss amount was 592,558$ for the existing technique and 563,571$ for the improved technique, which was reduced by about 5% compared to the previous one.This proved that a more precise evaluation is possible and that the efforts for safety at the workplace are reflected in the evaluation results.

MACT Application Effect in Petrochemical Industry to Minimize Benzene Fugitive Emission (석유화학산업의 벤젠 비산배출 저감을 위한 MACT 적용효과)

  • Kim, HunJang;Moon, Jinyoung;Hwang, Yongwoo;Kwak, Inho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.435-443
    • /
    • 2016
  • In this study, MACT (Maximum Achievable Control Technology) application effect was evaluated for minimization of benzene fugitive emission in petrochemical industry. Although fugitive emission for benzene in the nation was regulated by the Clean Air Conservation Act from 2015, the US EPA already has introduced MACT standard to minimize its emission with up-to-date technology since 1995. EPA Emission Factor (AP-42) and EPA MACT Standard Guideline were used to assess MACT application effect. As a result, For MACT application it could reduce benzene emission up to 98% (average) comparing with uncontrolled facility, while the national regulation could achieve about 95% (average) reduction which is slightly lower than MACT. However there is no control measure in the national regulation to reduce benzene emission for vessel loading even though MACT standard requires preventive facility such as VRU (Vapor Recovery Unit). For further reduction of benzene emission, it needs to be mandatory for operation of VRU when benzene product is loaded in vessel. These efforts could contribute to achieve the global level for benzene emission management in national petrochemical industry.

The Satisfaction Analysis of Senior-Friendly Park Using Fuzzy Comprehensive Evaluation (퍼지 종합 평가를 활용한 노인 친화형 공원 만족도 분석)

  • Yin, Xiaoyan;Jung, Taeyeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.89-101
    • /
    • 2022
  • The study was conducted in Erhe Park, a neighborhood park in Dali City, China, to derive the influence of environmental factors in the park on the elderly's satisfaction and to analyze the satisfaction in order to provide improvement recommendations. First, the evaluation indicators were selected, by referencing previous research into the elderly's evaluation of external spatial environments and the influence of various factors was determined from the questionnaire and factor analysis. Second, a fuzzy comprehensive evaluation was conducted to understand the satisfaction of the elderly, and then an Importance-Performance Analysis(IPA) analysis was conducted to develop improvement recommendations. Results of the factor analysis showed that park's environmental factors were grouped into four categories: facility suitability and comfort, safety and convenience of use, natural environment comfort, and parkway convenience. Based on this, the overall satisfaction rating for the environmental factors in Erhe Park was between satisfactory and average. The natural environment comfort was rated satisfactory, the facility suitability and comfort, and convenience and safety were rated average, and parkway convenience was rated near to satisfaction. The IPA analysis revealed that the suitability of rest facilities, suitability of convenience facilities, facility management status, safety of entrances and exits, and nighttime lighting facilities were items of high importance but low satisfaction that needed to be improved. The results of this study can be utilized as a guide for future building or readjustment of senior-friendly parks, and they are critical for increasing senior-friendly park satisfaction.

Analysis of User Requirements for Development of Vessel Traffic Services Cloud System (선박교통관제 클라우드 시스템 개발에 따른 사용자 요구사항 분석)

  • Lee, Li-Na;Kim, Joo-Sung;Lee, Hong-Hoon;Lee, Jin-Suk;Namgung, Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.314-323
    • /
    • 2022
  • Vessel Traffic Services (VTS) operators perform traffic management tasks using VTS systems and sensor equipment designated as VTS facilities to promote the safety and efficiency of vessel traffic. The necessary VTS information for effective operations could be obtained through the additional access of various information channels other than the designated VTS facility. To unify these various information access windows, the development of the VTS cloud system is in progress. In this study, the operational information analysis for VTS was performed through VTS tasks-facility linkage analysis to identify the user required information according to the introduction of the VTS cloud system. The VTS task analysis was performed through research of the international and domestic literature, and expert interviews. The necessary information were identified and linked according to the VTS facilities. As a result of the analysis, 37 categories of necessary information were identified for internal and external information windows, and 8 information windows were selected other than the present VTS equipment. The identified user requirements would be applied to the structure design of the VTS cloud system. In the future, it is necessary to update user requirements through scenario-based user operation analysis and to conduct additional research on the system interface design.

Management Methods of Bone Mineral Density Examination Using Dual Energy X-ray Absorptiometry (이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법)

  • Kim, Ho-Sung;Kim, Tae-Hyung;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.351-360
    • /
    • 2018
  • In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

A Study on the Verification of water level criteria for forecasting system of reservoir failure (저수지 붕괴예보 시스템의 수위기준 검증 연구)

  • Lee, Baeg;Choi, Byounghan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • The loss of safety for reservoirs brought about by climate change and facility aging leads to reservoir failures, which results in the loss of lives and property damage in downstream areas. Therefore, it is necessary to provide a Reservoir Failure Forecasting System for downstream residents to detect the early signs of failure (with sensors) in real-time and perform safety management to prevent and minimize possible damage. For the verification of established water level management criteria, 10 water level data up to reservoir capacity was selected. Weight factor and trend line were applied to dramatic increase section of water level in the 1 year period data. The results shows that water level criteria based on three even parts shows less than 7% of standard deviation and it is appropriate to verify management criteria.

An Integrated Emergency Call System based on Public Switched Telephone Network for Elevators

  • Lee, Guisun;Ryu, Hyunmi;Park, Sunggon;Cho, Sungguk;Jeon, Byungkook
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.69-77
    • /
    • 2019
  • Today, most of elevators have an emergency call facility for emergency situations. However, if the network installed in the elevator is also out of power, it cannot be used for the elevator remote monitoring and management. So, we develop an integrated and unified emergency call system, which can transmit not only telephone call but also data signals using PSTN(Public Switched Telephone Network) in order to remote monitoring and management of elevators, even though a power outage occurs. The proposed integrated emergency call system to process multiple data such as voice and operational information is a multi-channel board system which is composed of an emergency phone signal processing module and an operational information processing module in the control box of elevator. In addition, the RMS(remote management server) systems based on the Web consist of a dial-up server and a remote monitoring server where manages the elevator's operating information, status records, and operational faults received via the proposed integrated and unified emergency call system in real time. So even if there's a catastrophic emergency, the proposed RMS systems shall ensure and maintain the safety of passengers inside the elevator. Also, remote control of the elevator by this system should be more efficient and secure. In near future, all elevator emergency call system need to support multifunctional capabilities to transmit operational data as well as phone calls for the safety of passengers. In addition, for safer elevators, it is necessary to improve them more efficiently by combining them with high-tech technologies such as the Internet of Things and artificial intelligence.

A Study on the development therapeutic environmental rating scales for the elderly people with dementia in nursing homes - Focused on the TESS-NH environmental rating scale Analysis (치매성 고령자를 위한 노인요양시설의 치료적 환경평가척도 개발에 관한 연구 - TESS-NH 환경평가척도 분석을 중심으로)

  • Lee, Young Chang
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.3
    • /
    • pp.49-55
    • /
    • 2014
  • Purpose: AIn recent years, the rapid progress of aging and the increase in the elderly people with dementia is becoming a big social issue. Therefore, this paper studies the development of therapeutic environmental rating scales for the elderly people with dementia in korean nursing homes. Methods: We identify the development process and structure of TESS-NH and understand the details of its nature and features. Then, based on the detailed items, we provide major scale factors which do influence on therapeutic environmental rating scales using PCA. Results: In the results, TESS, in the case of the initial stage of TESS-NH, has an advantage to evaluate on physical environments for a short period of time. TESS-2 + sets a large rage of activities of the elderly people with dementia, and tries to evaluate ongoing cares. TESS-NH has a complete set of well-thought-out assessment features for improving quality of care (Quality of Care) On the other hand, the main factors affecting the therapeutic environmental rating scales in nursing homes are "a consideration for facility management (Care for facilities' maintenance)", "a consideration for spatial cognition (Care for spatial cognition) ", and "a consideration for the safety (Care for safety)". Implications: In the future, to develop the therapeutic environmental rating scales on Korea's dementia nursing home, we should actively consider cares of spaces and facility utilization which the residents (the elderly people with dementia) are more secure and comfortable.