• Title/Summary/Keyword: facility monitoring

Search Result 578, Processing Time 0.03 seconds

Monitoring System to Measure the Waste Volume of Landfill Facility using 3D Laser Scanner (3D 레이저 스캐너를 이용한 매립장의 체적 계측을 위한 모니터링시스템)

  • Cho, Sung-Youn;Lee, Young-Dae;Ryu, Seung-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • In this paper, we discussed about the volume monitoring system of a landfill facility. We proposed the waste volume calculation method using the point cloud of the surface of three dimensional object by measurement of the point cloud by the three dimensional scanner, which is based upon the robot technique. This computes not only the quantity of waste volume for continuos monitoring but also it helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, the measuring system of waste volume was applied to the landfill facility in Ansung city.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

Rectification of Smartphone Image Based on Reference Images for Facility Monitoring (시설물 모니터링을 위한 기준영상 기반 스마트폰 영상의 기하보정)

  • Kim, Hwiyoung;Choi, Kyoungah;Lee, Impyeong;Yoon, Hyuk-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.231-242
    • /
    • 2017
  • Monitoring of facilities such as roads, dams and bridges is important for their long-term sustainable usage. It has usually suffered with safety and cost problems, which makes more frequent monitoring difficult. As an efficient and economicalsolution to these problems, one may consider the use of smartphone to capture the status of the facilities. To derive quantitative analysis results with the smartphone images for facility monitoring, one should first rectify the images in a way as automatic and economical as possible. In thisstudy, we propose such a rectification method, which rectifiessmartphone images acquired from arbitrary locations based on reference images.In the proposed method, we determine the camera extrinsic parameters of each smartphone images using the reference imagesrather than ground control points, and project the image to the target surface of the facility based on the determined camera parameters. The method were applied to test data acquired from a small dam toward water-area facility monitoring. The experimental results showed that the camera extrinsic parameters were determined with the accuracy of 5 cm and $0.28^{\circ}$ in the position and attitude. The accuracy of the distance measured from the rectified image was evaluated to 10 cm. With the rectified images, one can accurately determine the location and length of the target objects required for facility monitoring.

UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower (UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계)

  • Lee, Dong-Cheol;Bae, Ul-Lok;Kim, Woo-Jung;Min, Bung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

A Study on the Priority Order Evaluation of the Water Supply Monitoring Technology Development for the Intelligent Underground Facility Management (지능형 지하시설물관리를 위한 상수도 모니터링 기술개발의 우선순위 평가에 관한 연구)

  • Kim, Jung-Hoon;Yi, Mi-Sook;Han, Jay-Il
    • Spatial Information Research
    • /
    • v.16 no.2
    • /
    • pp.263-278
    • /
    • 2008
  • Nowaday, local governments have planned to manage intelligent underground facilities through the u-City project. But, the intelligent underground facilities are in need of the progressive approach because of the required huge financial resources. Therefore, the objectives of this research are (1) to prioritize the monitoring items of sensing technology developments, (2) to study technological feasibilities, and (3) to discover the killer application which expands ripple effects on economy. To achieve these objectives, final monitoring items were derived from the business analysis of the water supply, the local government survey, the hearing expert opinions and so on. The priority order of final monitoring items were technology developments of (1) the flowmeter flux, (2) the water leakage/crack, (3) the pressure of water supply pipes, and (4) the flux of filtration plants. The research significance is obtained from the derivation and the evaluation of the priority order and the actual demand for the water supply facility management. And, the research results will contribute to the strategic planning for the underground facility intelligence.

  • PDF

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.

전기체 구조시험 설비 감시 시스템

  • Chae, Dong-Chul;Hwang, Gui-Chul;Song, Jae-Chang;Shim, Jae-Yeul
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2003
  • Full-scale test facility is a huge system which is integrated by many subsystems. There are several critical elements in test facility system. Those elements may cause undesirably test article failure during testing. Therefore, test facility monitoring system which indicates the operating status of the critical elements is required for performing full-scale structural test. Selection of critical element and design of this monitoring system are explained in detail in this paper. The monitoring system developed are being applied to T-50 full-scale static test, will be expended for full-scale fatigue test in the near future.

  • PDF

A Design of N-Screen based Monitoring System for Marine-Facility (N-Screen 기반의 해양시설물용 모니터링 시스템 설계)

  • Kim, Ji-Yoon;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.613-622
    • /
    • 2015
  • The convergence of IT technology and marine facilities monitoring system is needed for effective monitoring systems to marine facilities. Especially the spread of smart device such as smart phone, smart pad, smart TV provide an environment that can check the status of the marine facility for marin facilities manager. However, smart phones and smart pads are used in a variety of OS used. Thus the monitoring system of the various service environments is difficult. In addition, There is inconvenience that must individually developed monitoring system for each device. In order to solve this problem NMMS (N-Screen Marine-facility Monitoring System) is proposed. NMMS is consist of Real-time monitoring system, Fault diagnosis system, Data storage system. To improve variety of smart devices accessibility, we use HTML 5. Through NMMS, marine facilities manager can use smart device such as PC, Notebook, smart phone, smart pad for marine facilities monitoring.

A Remote Monitoring and Control System for Waste Treatment Facility via Public Communication Network.

  • Jung, Jae-Hak;Choi, Jin-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.124.2-124
    • /
    • 2001
  • The research for development of remote monitoring and control systems composed three stages of research categories. At the first stage, we decided the suitable instrumentation devices for interface between H/W systems and waste water treatment facility. And at the second stage, we developed the software package for remote monitoring and data transmission system including data receipt system via wired telephone line. At the final stage we developed local control system for auto-process control of waste water treatment facilities. For the first stage of research we developed the a drawing of design the instrumentation and selected optimal sensors or monitoring basic important data. After the first stage research we developed the software package with Graphic User Interface(GUI) ...

  • PDF

Determination of Location and Depth for Groundwater Monitoring Wells Around Nuclear Facility (원자력이용시설 주변의 지하수 감시공의 위치와 심도 선정)

  • Park, Kyung-Woo;Kwon, Jang-Soon;Ji, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.245-261
    • /
    • 2019
  • Radioactive contaminant from a nuclear facility moves to the ecosystem by run-off or groundwater flow. Among the two mechanisms, contaminant plume through a river can be easily detected through a surface water monitoring system, but radioactive contaminant transport in groundwater is difficult to monitor because of lack of information on flow path. To understand the contaminant flow in groundwater, understanding of the geo-environment is needed. We suggest a method to decide on monitoring location and points around an imaginary nuclear facility by using the results of site characterization in the study area. To decide the location of a monitoring well, groundwater flow modeling around the study area was conducted. The results show that, taking account of groundwater flow direction, the monitoring well should be located at the downstream area. Also, monitoring sections in the monitoring well were selected, points at which groundwater moves fast through the flow path. The method suggested in the study will be widely used to detect potential groundwater contamination in the field of oil storage caverns, pollution by agricultural use, as well as nuclear use facilities including nuclear power plants.