• Title/Summary/Keyword: fNIRS

Search Result 39, Processing Time 0.024 seconds

CHEMICAL AND MICROBIOLOGICAL ANALYSIS OF GOAT MILK, CHEESE AND WHEY BY NIRS

  • Perez Marin, M.D.;Garrido Varo, A.;Serradilla, J.M.;Nunez, N.;Ares, J.L.;Sanchez, J.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1513-1513
    • /
    • 2001
  • Present Food Legislation compels dairy industry to carry out analyses in order to guarantee the food safety and quality of products. Furthermore, in many cases industry pays milk according to bacteriological or/and nutritional quality. In order to do these analyses, several expensive instruments are needed (Milkoscan, Fossomatic, Bactoscan). NIRS technology Provides a unique instrument to deal with all analytical requirements. It offers as main advantages its speed and, specially, its versatility, since not only allows determine all the parameters required in milk analysis, but also allows analyse other dairy products, like cheese or whey. The objective of this study is to develop NIRS calibration equations to predict several quality parameters in goat milk, cheese and whey. Three sets of 123 milk samples, 190 cheese samples and 109 whey samples, have been analysed in a FOSS NIR Systems 6500 I spectrophotometer equipped with a spinning module. Milk and whey were analysed by folded transmission, using circular cells with gold surface and pathlength of 0.1 m, while intact cheese was analysed by reflectance using standard circular cells. NIRS calibrations were obtained for the prediction of chemical composition in goat milk, for fat (r$^2$=0.92; SECV=0.20%), total solids (r$^2$=0.95: SECV=0.22%), protein (r$^2$=0.94; SECV=0.07%), casein (r$^2$=0.93; SECV=0.07%) and lactose (r$^2$=0.89; SECV=0.05%). Moreover, equations have been performed to determine somatic cells (r$^2$=0.81; SECV=276.89%) and total bacteria (r$^2$=0.58; SECV=499.32%) counts in goat milk. In the case of cheese, calibrations were obtained for the prediction of fat (r$^2$=0.92; SECV=0.57), total solids (r$^2$=0.80; SECV=0.92%) and protein (r$^2$=0.70; SECV=0.63%). In whey, fat (r$^2$=0.66; SECV=0.08%), total solids (r$^2$=0.67; SECV=0.19%) and protein (r$^2$=0.76; SECV=0.07%) NIRS equations were obtained. These results proved the viability of NIRS technology to predict chemical and microbiological parameters and somatic cells count in goat milk, as well as chemical composition of goat cheese and whey.

  • PDF

Neuro-scientific Approach to Fashion Visual Merchandising -Comparison of Brain Activation to Positive/Negative VM in Fashion Store Using fNIRS- (패션 비주얼머천다이징의 뇌 과학적 접근 -fNIRS를 이용한 패션매장의 긍정적/부정적 VM에 대한 뇌 활성 비교-)

  • Kim, Hyoung Suk;Lee, Jin Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.2
    • /
    • pp.254-265
    • /
    • 2017
  • This study examines the possibility of a neuro-scientific approach to fashion Visual Merchandising (VM), by researching the brain activation of customers about fashion stores in terms of VM. Study subjects were in 20's-30's residing in Busan and ten ordinary person or fashion industry related individuals, it measures the change of cerebral blood flow on positive/negative photo stimulus in terms of VM using a functional Near Infrared Spectroscopy (fNIRS) device, and then compared the brain activation to the difference of the fashion store VM. Photo stimuli utilized in the experiment were selected through a preliminary study in advance. The results of this study are as follows. First, the brain activation was found in all 16 channels of stimulus ranges of fashion store VM regardless of positive/negative stimulus. This means that the VM of fashion store causes changes to the cerebral blood flow of consumers, which implies that consumer behavior can be affected by store VM. It also shows that the brain is more active in negative VM stimulus than positive VM despite slight differences in the subjects. In terms of VM, this suggests that the negative factors of fashion stores have a greater effect on the brains of consumers compared to the positive factors. Second, the reaction of the brain channel is different according to the positive/negative VM stimulus of the fashion store by product group and confirms that positive/negative VM stimulus can be distinguished by brain-reaction for the three product groups except for the underwear group among four product groups (men's wear store, women's wear store, underwear store, and sportswear store). The results indicate that more objective scientific measure and decision-making are possible through neuro-science in the strategic execution of VM. This study verified the possibility for a neuro-scientific approach to fashion VM; therefore, there are expectations for the various activation of interdisciplinary research and subsequent development of VM that utilize neuroscience in fashion marketing.

Statistical Treatment on Amylose and Protein Contents in Rice Variety Germplasm Based on the Data Obtained from Analysis of Near-Infrared Reflectance Spectroscopy (NIRS)

  • Oh, Sejong;Chae, Byungsoo;Lee, Myung Chul;Choi, Yu Mi;Lee, Sukyeung;Rauf, Muhammad;Hyun, Do Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.04a
    • /
    • pp.31-31
    • /
    • 2018
  • The purpose of this study was to statistically analyze amylose and protein content of rice variety resources collected from China (1,542), Japan (1,409), Korea (413), and India (287). The statistical analysis was conducted using ANOVA and DMRT based on the data obtained from NIRS analysis. The average amylose contents were 18.85% in Japanese, 19.99% in Korean, 20.27% in Chinese, and 25.46% in Indian resources. The average protein contents were 7.23% in Korean, 7.73% in Japanese, 8.01% in Chinese, and 8.17% in Indian resources. The amylose and protein content using ANOVA showed significant differences at the level of 0.01. The F-test for amylose content was 158.34, and for protein content was 53.95 compared to critical value 3.78. The amylose and protein content using DMRT (p<0.01) showed significant difference between countries. The value of statistical treatment was divided into three groups such as $China^a$, $Korea^a$, $Japan^b$, $India^c$ in amylose and $China^a$, $India^a$, $Japan^b$, $Korea^c$ in protein. Japanese resources had the lowest level of amylose contents, whereas, the lowest level of protein content was found in Korean resources compared to other origins. Indian resources showed the highest level of amylose and protein contents. It is recommended that these results could be helpful to future breeding experiments.

  • PDF

Studies on Thermal Stability and Cure Behavior of Epoxy Resins using Electron-beam Curing Technique (전자선 경화를 이용한 에폭시 수지의 열안정성과 경화동력학에 관한 연구)

  • 박수진;허건영;이재락
    • Composites Research
    • /
    • v.15 no.2
    • /
    • pp.40-47
    • /
    • 2002
  • The di-functional epoxy resins, i.e., diglycidylether of bisphenol A(DGEBA) and diglycidylethere of bisphenol F(DGEBF) were initiated by cationic catalyst, i.e., benzylquinoxalinium hexafluoroantimonate(BQH) using electron-beam(EB) technique. And the effect of structure of DGEBA and DGEBF on thermal stabilities and cure behaviors was investigated. According to the experimental results, the decomposed activation energy based on Horowitz-Metzger method was higher in the case of DGEBA, but intergral procedural decomposition temperature(IPDT) of DGEBA was lower than DGEBF. This could be interpreted in terms of high crosslink density resulted from hydroxyl bond of DGEBF backbone. It was confirmed in increasing the hydroxyl band at $7000\;cm^{-1}$ and $5235\;cm^{-1}$ using near-infrared spectroscopy(NIRS).

Estimation of Causal Connectivity between Cortical Areas Using Near-Infrared Spectroscopy (NIRS) (근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석)

  • Lee, Seung-Deok;Go, Dal-Gwon;Jeong, Yeong-Jin;Kim, Do-Won;Im, Chang-Hwan;Kim, Beop-Min
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.151-152
    • /
    • 2009
  • 최근 신경과학 분야에서 대뇌피질 영역 간 연관성 분석은 신경학적 질병 (자폐증, 간질, 정신 분열증)의 분석 및 진단에 적용되고 있다. 기존 대뇌피질 영역 간 연관성 분석은 뇌전도 (EEG), 기능적 자기공명영상 (fMRI), 뇌자도 (MEG)등이 이용되었지만, 뇌전도의 낮은 공간분해능, 기능적 자기공명영상의 낮은 시분해능 등은 영역 간 연관성 분석에 단점으로 작용되고 있다. 반면, 근적외선 분광법(NIRS)은 대뇌피질에서의 혈류변화(oxy-, deoxy-hemoglobin)를 비침습적이며 빠른 시분해능으로 측정할 수 있는 방법으로 최근 신경과학 분야에 응용되고 있다 [1-2]. 본 논문에서는 근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석의 효용성을 입증하기 위해, 쥐의 수염자극 시 대응되는 지역 (일차-, 이차 체감각피질, 일차 운동피질 영역)에서의 혈류변화 신호의 영역 간 연관성 분석을 하였다. 본 연구결과에 의하면 수염자극 시 일차-, 이차 체감각피질 영역에서의 방향성은 확인할 수 없었고, 일차-, 이차 체감각피질 영역에서 일차 운동피질영역으로의 방향성은 확인할 수 있었다. 본 결과는 기존 수염자극 시 활성화되는 전기신호의 패턴과 일치하며, 향후 신경과학적 질병의 분석 및 진단에 근적외선을 이용한 대뇌피질 영역 간 연관성 분석이 유용할 수 있음을 보여준다.

  • PDF

A Case Study on the Effectiveness of tDCS to Reduce Cyber-Sickness in Subjects with Dizziness

  • Chang Ju Kim;Yoon Tae Hwang;Yu Min Ko;Seong Ho Yun;Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.36 no.1
    • /
    • pp.39-44
    • /
    • 2024
  • Purpose: Cybersickness is a type of motion sickness induced by virtual reality (VR) or augmented reality (AR) environments that presents symptoms including nausea, dizziness, and headaches. This study aimed to investigate how cathodal transcranial direct current stimulation (tDCS) alleviates motion sickness symptoms and modulates brain activity in individuals experiencing cybersickness after exposure to a VR environment. Methods: This study was performed on two groups of healthy adults with cybersickness symptoms. Subjects were randomly assigned to receive either cathodal tDCS intervention or sham tDCS intervention. Brain activity during VR stimulation was measured by 38-channel functional near-infrared spectroscopy (fNIRS). tDCS was administered to the right temporoparietal junction (TPJ) for 20 minutes at an intensity of 2mA, and the severity of cybersickness was assessed pre- and post-intervention using a simulator sickness questionnaire (SSQ). Result: Following the experiment, cybersickness symptoms in subjects who received cathodal tDCS intervention were reduced based on SSQ scores, whereas those who received sham tDCS showed no significant change. fNIRS analysis revealed that tDCS significantly diminished cortical activity in subjects with high activity in temporal and parietal lobes, whereas high cortical activity was maintained in these regions after intervention in subjects who received sham tDCS. Conclusion: These findings suggest that cathodal tDCS applied to the right TPJ region in young adults experiencing cybersickness effectively reduces motion sickness induced by VR environments.

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF

Discrimination of Geographical Origin for Astragalus Root (Astragalus membranaceus) by Capillary Electrophoresis and Near-Infrared Spectroscopy (Capillary electrophoresis 및 근적외선분광분석기를 이용한 황기의 원산지 판별)

  • Kim, Eun-Young;Kim, Jung-Hyun;Lee, Nam-Yun;Kim, Soo-Jeong;Rhyu, Mee-Ra
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.818-824
    • /
    • 2003
  • Capillary electrophoresis (CE) and near-infrared spectroscopy (NIRS) were performed to discriminate astragalus roots (Astragalus membranaceus) according to geographical origin (domestic or foreign). Two-hundred-and-four astragalus roots were extracted with 30% methanol in 0.1 M phosphate buffer (pH 2.5) and separated in a uncoated fused-silica $(50\;{\mu}m{\times}27\;cm)$ capillary. Conditions for optimal analysis included: temperature $-45^{\circ}C$, voltage -14 kV, and pressure injection time -8 sec. The optimal separation buffer was 0.1 M phosphate buffer (pH 2.5) containing 40 mM hexane sulfonic acid with 20% 2-methoxy ethanol. Raw NIR spectra were obtained using NIRS, and modified partial least square regression was used to develop the prediction model. The correlation coefficient and standard error of prediction were 0.915 and 14.3%, respectively. Under the optimal conditions established for CE and NIRS, the geographical origins of the astragalus roots were correctly identified in 80 and 97%, respectively. Astragalus roots that were not discriminated by NIRS were correctly discriminated by CE. Hence, CE and NIRS are potential methods for discriminating the geographical origins of astragalus roots that complement one another.

IDENTIFICATION OF FALSIFIED DRUGS USING NEAR-INFRARED SPECTROSCOPY

  • Scafi, Sergio H.F.;Pasquini, Celio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3112-3112
    • /
    • 2001
  • Near-Infrared Spectroscopy (NIRS) was investigated aiming at the identification of falsified drugs. The identification is based on comparison of the NIR spectrum of a sample with a typical spectra of an authentic drug using multivariate modelling and classification algorithms (PCA/SIMCA). Two spectrophotometers (Brimrose - Luminar 2000 and 2030), based on acoustic-optical filter (AOTF) technology, sharing the same controlling computer, software (Brimrose - Snap 2.03) and the data acquisition electronics, were employed. The Luminar 2000 scans the range 850 1800 nm and was employed for transmitance/absorbance measurements of liquids with a transflectance optical bundle probe with total optical path of 5 mm and a circular area of 0.5 $\textrm{cm}^2$. Model 2030 scans the rage 1100 2400 nm and was employed for reflectance measurement of solids drugs. 300 spectra, acquired in about 20 s, were averaged for each sample. Chemometric treatment of the spectral data, modelling and classification were performed by using the Unscrambler 7.5 software (CAMO Norway). This package provides the Principal Component Analysis (PCA) and SIMCA algorithms, used for modelling and classification, respectively. Initially, NIRS was evaluated for spectrum acquisition of various drugs, selected in order to accomplish the diversity of physico-chemical characteristics found among commercial products. Parameters which could affect the spectra of a given drug (especially if presented as solid tablets) were investigated and the results showed that the first derivative can minimize spectral changes associated with tablet geometry, physical differences in their faces and position in relation to the probe beam. The effect of ambient humidity and temperature were also investigated. The first factor needs to be controlled for model construction because the ambient humidity can cause spectral alterations that should cause the wrong classification of a real drug if the factor is not considered by the model.

  • PDF

Discriminant Analysis of Cigarette Brands by Nearinfrared Spectroscopy (근적외선 분광법을 이용한 제품담배 판별 연구)

  • ;F.E. Barton
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.2
    • /
    • pp.163-171
    • /
    • 1994
  • This experiment was conducted to investigate the discrimination of cigarette brands and the similarity between Korea and America cigarette brands by near infrared spectra. Statistical tools such as principal component analysis (PCA) and mahalanobis distance(M.D) were used. The discrimination rate of the Korea and the America cigarette brands, determined by position number which was calculated with PCA and M.D, was 94% and 87%, respectively. The spectra of the 10 America cigarette brands were selected by averaging 5 sample spectra for each brand and another 5 spectra for each brand were investigated to use as the sample spectra. Comparing the sample spectra with the selected spectra by M.D using 410-1090 nm, 1110-1850 nm and 1970-2490 nm wavelength, the discrimination rate which was determined by the closest M.D between the sample and the selected spectra was 100% when each spectra was investigated on the same time. But the discrimination rate decreased 50% when the sample and the selected spectra were investigated on the different time. Excluding 1970-2490 nm wavelength, the discrimination rate increased up to 90% when the sample and the selected spectra were investigated on the different time. Comparing the spectra of Korea cigarette brands with those of America cigarette brands by M.D using only 410-1090 nm and 1110-1850 nm wavelength, the spectra of Expo(G) was similar to Winston, Vantage(U.L) and Benson & hedges(M.), the spectra of Hanaro(D) was similar to Carrel, Winston(L), Vantage(U.L), \Vantage and Carrel(L), the spectra of Hanaro(L) was similar to Winston(L) , Carton, Vantage and Carmel(L) and the spectra of Pinetree was similar to Kent, Kool, Kent(G.L), Merit and Benson & hedges(L), respectively. Key Words : NIRS, cigarette brands discrimination

  • PDF