• Title/Summary/Keyword: f-stable

Search Result 785, Processing Time 0.024 seconds

Effects of Fluorides in the Flux Cored Wire on the Oxygen Content of Weld Metal (플럭스 코어드 와이어의 불화물 종류에 따른 용접금속 산소량의 변화)

  • Cha, Joo-hyeon;Bang, Kook-soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.615-619
    • /
    • 2019
  • Various fluorides, i.e., CaF2, Na3AlF6, K2SiF6, MnF3, MgF2, were added to the flux cored wire, and their effects on the oxygen content of the weld metal were investigated. The investigation showed that the oxygen content of weld metal was not influenced by the type of metallic elements in the fluoride; rather, it was influenced by the stability of the arc during welding. While the wire containing MgF2 showed the most stable arc and the least amount of oxygen in the weld metal, the wire containing MnF3 showed the least stable arc and the greatest amount of oxygen. Since the deoxidation of the weld metal was not affected by the deoxidation elements, such as Ca and Mg, it was possible to predict the oxygen content of the weld metal by the equilibrium Si-Mn deoxidation thermodynamic model.

Ab Initio Studies on the $(HF)_2(CO)$ Trimers ($(HF)_2(CO)$ 분자착물에 관한 Ab Initio 연구)

  • Kim, Seung Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.629-637
    • /
    • 1998
  • The HF-SCF, MP2 and B3LYP calculations have been performed on the two conceivable clusters $(HF)_2(CO)$ trimers as well as their dimer complexes FH…FH, FH…CO and FH…OC applying $6-31+G^{\ast}^{\ast}$, and $6-311+G^{\ast}^{\ast}$ basis sets. A variety of ground state properties of these trimer complexes have been listed, and compared with corresponding properties of isolated monomers and combined dimers. It was calculated that FH…CO is more stable than FH…OC by average 0.85 kcal/mol and F-H…F-H…C≡O is more stable than F-H…F-H…O≡C by 1-2 kcal/mol. The C≡O stretching bands of the F-H…F-H…C≡O and F-H…F-H…O≡C were red shifted by 24, $37\;cm^{-1}$ compared with the FH…CO and FH…OC respectively. Also, H-F stretching bands were red shifted by 54 and $353\;cm^{-1}$.

  • PDF

ON THE EXISTENCE OF STABLE MINIMAL HYPERSURFACES OF THE THREE DIMENSIONAL CRITICAL POINT EQUATION

  • CHANG, JEONGWOOK
    • Honam Mathematical Journal
    • /
    • v.28 no.3
    • /
    • pp.409-415
    • /
    • 2006
  • On a compact oriented smooth 3-dimensional manifold (M, g), we consider the critical point equation(CPE) defined as $z_g=s^{{\prime}*}_g(f)$. Under CPE, it is shown in [5] that every stable minimal hypersurface in M is contained in ${\varphi}^{-1}(0)$ for ${\varphi}{\in}$ ker $s^{{\prime}*}_g$. We study analytic and geometric conditions under which the stable minimal hypersurface in M does not exist.

  • PDF

The Air/water Interface Characteristics of Maleate Copolymer LB Films (말레에이트계 공중합체 I-l3막의 공기/물에서의 계면 특성)

  • 신훈규;권영수;이범종;장정수;배진호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.220-223
    • /
    • 1995
  • Stable polyion-complexed polymeric monolayrers were prepared by spreading perfluoroalkyl monomaleatd copolymers. C$_2$F$\_$8/MA-VE$_2$ and C$_2$F$\_$8/Mv-VE$_3$ on aqueous poly(allylamine) subphase. The monolayer properties have been studied by the surface pressure-area($\pi$-A) isotherms. The C$_2$F$\_$8/MA-VE$_3$containing longer oligoethyleneglycol pendant showed more expaned monolayer phase than the C$_2$F$\_$8/MA-VE$_2$ The polyion-complexed monolayers were transferable on various substrates, and the resulting Langmuir-Blodgett(LB) films were characterized b ET-IR spectroscopy and scanning electron microscopy(SEM) Two-dimensional crosslinking to from a polymer network was achieved by amide formation through heat treatment under vacuum with concurrent removel of perfluoroalkyl tails. SEM observation of this film ona porous membrane filter showed that the four layer film was sufficiently stable to cover the filter pore size of 0.1$\mu\textrm{m}$. The C$_2$F$\_$8/MA-VE$_3$revealed better covering capability than the C$_2$F$\_$8/MA-VE$_2$Immersion of this film in water or in benzend did not cause any change in its appearance and in FT-IR spectra.

  • PDF

Langmuir-Blodgett Films of Perfluoroalkyl Monomaleate Copolymers on Porous Substrate

  • Hyein Jeong;Burm-Jong Lee;Young-Soo Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.8
    • /
    • pp.650-654
    • /
    • 1994
  • Stable polyion-complexed polymeric monolayers were prepared by spreading perfluoroalkyl monomaleate copolymers, $C_2F_8MA-VE_2$ and $C_2F_8MA-VE_3$, on a aqueous poly(allylamine) subphase. The monolayer properties have been studied by the surface pressure-area (${\pi}$-A) isotherms. The $C_2F_8MA-VE_3$ containing longer oligoethyleneglycol pendant showed more expanded monolayer phase than the $C_2F_8MA-VE_2$. The polyion-complexed monolayers were transferable on various substrates, and the resulting Langmuir-Blodgett (LB) films were characterized by FT-IR spectroscopy and scanning electron microscopy (SEM). Two-dimensional crosslinking to form a polymer network was achieved by amide formation through heat treatment under vacuum with concurrent removal of perfluoroalkyl tails. SEM observation of this film on a porous membrane filter showed that the four layer film was sufficiently stable to cover the filter pore size of 0.1 ${\mu}$m. The $C_2F_8MA-VE_3$ revealed better covering capability than the $C_2F_8MA-VE_2$. Immersion of this film in water or in benzene did not cause any change in its appearance and in Fl-IR spectra.

Dynamic and static structure analysis of the Obermeyer gate under overflow conditions

  • Feng, Jinhai;Zhou, Shiyue;Xue, Boxiang;Chen, Diyi;Sun, Guoyong;Li, Huanhuan
    • Computers and Concrete
    • /
    • v.29 no.4
    • /
    • pp.209-217
    • /
    • 2022
  • In order to analyze the static and dynamic structural characteristics of the Obermeyer gate under overflow conditions, the force characteristics and vibration characteristics of the shield plate structure are studied based on the fluid-solid coupling theory. In this paper, the effects of the flow rate, airbag pressure and overflow water level on the structural performance of shield plate of air shield dam are explored through the method of controlling variables. The results show that the maximum equivalent stress and total deformation of the shield plate decrease first and then increase with the flow velocity. In addition, they are positively correlated with the airbag pressure. What's more, we find that the maximum equivalent stress of the shield plate decreases first and then increases with the overflow water level, and the total deformation of the shield plate decreases with the overflow water level. What's more importantly, the natural frequency of the shield structure of the Obermeyer gate is concentrated at 50 Hz and 100 Hz, so there is still the possibility of resonance. Once the resonance occurs, the free edge of the shield vibrates back and forth. This work may provide a theoretical reference for the safe and stable operation of the shield of the Obermeyer gate.

Heart rate variability of students in hospital clinical practice by MBTI character types (MBTI성격유형에 따른 병원 임상실습 중인 응급구조학과 학생의 심박변이도 변화에 관한 연구)

  • Jung, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6373-6386
    • /
    • 2013
  • This study examined the relationship between the MBTI character types and heart rate variability. The subjects were 25 students in the department of emergency medical technology in C city, Chungnam, Korea. The heart rate variability was measured under two conditions: a stable state, and in the second week and fourth week in clinical practice. The period of the heart rate variability measurements was from Jun. 21, 2013 to Jul. 26, 2013.The changes in the HRV at the stable state and during clinical practice depending on the MBTI character types, and the HRV at the stable state and during clinical practice according to the distribution chart of four character types showed a significant difference in the nHF and standard deviation of all R-R intervals (SDNN). In the changes in the HRV at the stable state and during clinical practice depending on the preference distribution chart of each indicator, the T-F group and J-P group in the nLF, T-F group and J-P group in the nHF, S-N group in the standard deviation of all R-R intervals (SDNN) and the J-P group in the mHR showed a significant difference.

Sources of Resistance to Bacterial Wilt Found in Vietnam Collections of Pepper (Capsicum annuum) and Their Nuclear Fertility Restorer Genotypes for Cytoplasmic Male Sterility

  • Tran, Ngoc Hung;Kim, Byung-Soo
    • The Plant Pathology Journal
    • /
    • v.28 no.4
    • /
    • pp.418-422
    • /
    • 2012
  • Eleven hot pepper accessions collected in Vietnam showed stable resistance to bacterial wilt as well-known resistance sources, MC4 and MC5, in repeated inoculation tests with different Ralstonia solanacearum isolates conducted from 2004 to 2010. Seven of these accessions (specifically KC981, KC1006, KC1021, KC1027, KC1045, KC1050, and KC1055) resulted in stable male sterile F1 plants in the crosses with a cytoplasmically male sterile (CMS) Chilseong (CMS-A, Srfrf ), and therefore, they were maintainers (CMS-B) with a genotype of Nrfrf. The rest (KC980, KC995, KC999, and KC1009) produced stable male fertile F1 plants in the crosses, and therefore, were restorers (CMS-C) with a genotype of N(S)RfRf. Therefore, the maintainer and restorer sources of resistance may be used in preference in breeding maternal (CMS and their maintainers) and paternal parents (restorers) for resistance to bacterial wilt, respectively, in the hybrid breeding system utilizing cytoplasmic male sterility.

Study on a Simulator for Generating Side Walking Path of the Biped Walking Robot (이족보행로봇의 횡보행 경로생성을 위한 시뮬레이터 연구)

  • Choi, Hyeung-Sik;Jeon, Chang-Hoon;Kang, Jin-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1285-1295
    • /
    • 2008
  • A research on a simulator for a side walking path of a 16 degree-of-freedom (d.o.f) biped walking robot(BWR) which is composed of 4 d.o.f upper-part body and 12 d.o.f lower-part of the body is presented. For generation of stable side walking motion, the kinematics, dynamics and the zero moment of point(ZMP) of the BWR were analyzed analytically and included in the simulator. To operate the motion simulator for stable side walking of the BWR, a graphic user interface program was developed which needs inputs for the side distance between legs, base joint angle, walking type, and walking velocity. The simulator was developed to generate joint angle data of legs for side walking, and the data are transmitted to the BWR for stable side walking. In the simulator, a new path function for smooth walking motion was proposed and applied to the simulator and actual motion of a BWR. Also for actual side walking, an algorithm for estimating backlashes of the actuating joint motors was proposed and included in the simulator. To validate the performance of the proposed motion simulator, the simulator was operated and its side walking data of the simulator were generated for a period of side walking.

A Closed Counter-Current Two-Phase Thermosyphon Loop of a Cold Neutron Source in HANARO Research Reactor (하나로 원자로에 설치될 대향 이상 열사이펀 루프에 관한 실험)

  • Hwang, Kwon-Sang;Cho, Man-Soon;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1038-1045
    • /
    • 2000
  • An experimental study was carried out to delineate the flow characteristics in a closed countescurrent two-phase thermo syphon with concentric tubes. This is to be installed in the HANARO research reactor as a part of a Cold Neutron Source(CNS). In the present investigation, experiments ata room temperature with Freon-II3 as a moderator were performed. Results show that, based on the magnitude of pressure fluctuation, the flow regimes could be divided into 4 distinct ones in the ($V_f,\;Q_i$) plane, where $V_f$ represents the volume of the charged liquid and $Q_i$ the heat load: a stable flow regime, an oscillatory flow regime, a restablized flow regime and a dryout flow regime. For $V_f$>2.5l, the flow is stable at low $Q_i$. However, as $Q_i$ increases, the flow becomes oscillatory and finally restablizes As $V_f$ increases, the oscillation amplitude decreases, reaching to the restablized flow region at low $Q_i$, and the liquid level in the moderator cell remains high. In the oscillatory flow regimes, for a fixed VI; the oscillating period of time varies with $Q_i$, having a minimum value at a certain value of $Q_i$. The heat load, where the oscillating period of time is minimum, decreases as $V_f$ increases.