• Title/Summary/Keyword: f-k filter

Search Result 327, Processing Time 0.029 seconds

Swell Noise Attenuation Using a Cascade of F-X Filter and Median Filter (F-X 필터와 중앙값 필터를 연속적으로 사용한 파랑잡음 제거)

  • Kim, Sookwan;Hong, Jong Kuk
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.199-208
    • /
    • 2012
  • High-amplitude swell noises (HASN) are very difficult to eliminate from the marine seismic data. In this paper, we applied F-X filter and median filter in order to suppress HASN. Test data have been acquired on the northern offshore of the South Shetland Islands in December, 2010. Parts of data have been contaminated by HASN caused by bad weather during the cruise. We applied F-X filter and median filter to test data with HASN. After F-X filtering, most of non-coherent noises and small-amplitude swell noises are eliminated effectively but HASN are still remained significantly. With median filter, HASN was suppressed better than F-X filter, however some of non-coherent noises are still remains. We applied a cascade of two filters and results show HASN and non-coherent noises are suppressed effectively. After the cascade of two filtering, it is possible to define reflection layers clearly on the velocity spectrum and to produce better stacked section with a good signal-to-noise ratio.

Fractional-order LβCα Low-Pass Filter Circuit

  • Zhou, Rui;Zhang, Run-Fan;Chen, Di-Yi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1597-1609
    • /
    • 2015
  • This paper introduces the fundamentals of the conventional LC low-pass filter circuit in the fractional domain. First, we study the new fundamentals of fractional-order LC low-pass filter circuit including the pure real angular frequency, the pure imaginary angular frequency and the short circuit angular frequency. Moreover, sensitivity analysis of the impedance characteristics and phase characteristics of the LC low-pass filter circuit with respect to the system variables is studied in detail, which shows the greater flexibility of the fractional-order filter circuit in designs. Furthermore, from the filtering property perspective, we systematically investigate the effects of the system variables (LC, frequency f and fractional orders) on the amplitude-frequency characteristics and phase-frequency characteristics. In addition, the detailed analyses of the cut-off frequency and filter factor are presented. Numerical experimental results are presented to verify the theoretical results introduced in this paper.

ON f-DERIVATIONS OF BE-ALGEBRAS

  • Kim, Kyung Ho;Davvaz, B.
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.28 no.1
    • /
    • pp.127-138
    • /
    • 2015
  • In this paper, we introduce the notion of f-derivation in a BE-algebra, and consider the properties of f-derivations. Also, we characterize the fixed set $Fix_d(X)$ and Kerd by f-derivations. Moreover, we prove that if d is a f-derivation of a BE-algebra, every f-filter F is a a d-invariant.

Evaluation of Filter-Adsorber(F/A) Process for Removal of Disinfection By-products(DBPs) (소독부산물 제어를 위한 실공정 F/A 운영에 관한 고찰)

  • Kim, Seong-Su;Lee, Kyung-Hyuk;Lim, Jae-Lim;Chae, Seon-Ha;Kang, Byeong-Soo;Moon, Pil-Joong;Ahn, Hyo-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1035-1042
    • /
    • 2005
  • Granular Activated Carbon(GAC) is widely used in drinking water treatment. At S and B Water Treatment Plant, GAC is used in place of granular media in conventional rapid filters(GAC Filter-Adsorber) for removal of Disinfection By-products(DBPs). The primary focus of this study is on the performance of existing filter-adsorber, and their operation. It was found that F/A process removed turbidity as effective as sand system. The ratio of Hydrophobic DOM (HPO) and hydrophilic DOM (HPI) fraction in the raw water at S and B WTP was similar. Filter Adsorber presented earlier DOC breakthrough and steady state condition which was contributed by biodegradation during operation period. The removal efficiency of DBPs were used to evaluate the filter performance. The DBPs concentration of F/A treated water was below treatment goal level (THM < $80\;{\mu}g/L$, HAA < $60{\mu}g/L$). The removal efficiency of THM decreased rapidly during operation period. However, HAA were removed steadily regardless of the influent concentration of HAA. These results indicate that the removal of THM depend upon the adsorption mechanism while the removal of HAA depend upon biodegradation as well as adsorption. The decrease of adsorption capacity and characteristic value of GAC may be attributed to the effect of high organic loading, residual free chlorine, coagulants, manganese oxidants and frequently backwashing. This study has confirmed that Filter adsorber process can be considered as effective alternatives for the removal of DBPs, especially HAA.

Analysis for the Bit Error Probability in the PCM-NRZ/FM Telemetry System (PCM-NRZ/FM Telemetry 시스템에서 Bit 오차확률에 관한 분석)

  • 강정수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.2
    • /
    • pp.76-81
    • /
    • 1983
  • PCM-NRZ/FM Telemetry system is constructed on the basis of RF link with FM modulatedand NRZ-L binary coded PCM data are assumed to transmit through 5th-order Bessel filter. Upon demodulated by the limiter-discriminator at the receiver, the probability of bit error, which is important for performance estimation of digital system, is analyzed against SNR. The analysis based on the following parameters, that is bit rate 140kHz, frequency of pre-modulation filter f-100kHz, maximum frequency deviation of transmitter 2f=300kHz, was performed. As a result, when the telemetry system with the parameters above is designed, the probability of bit error is obtained as 10 along with fT=0.7 and h=2, T=2.

  • PDF

FBG Sensor Signal Processing System using SLD Tunable Light Source and Etalon Filter (SLD동조 광원과 에탈론 필터를 이용한 FBG 센서 신호처리 시스템)

  • Chung, Chul;Lee, Ho-Joon;Kim, Ki-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.39-44
    • /
    • 2004
  • Fiber Bragg grating sensors are fabricated by core index modulation using UV laser and phasemask. Bragg wavelength of the grating is changed by the external strain. In this paper, a signal processing system of fiber Bragg grating sensor has studied in the optical wavelength domain. The system is based on the sweep semiconductor light source that consists of SLD, F-P tunable filter and etalon filter. The hysteresis effects of PZT in the F-P tunable filter are compensated. The long term measurement stability is obtained by controlling the temperature of F-P tunable filter and the SLD. We compare the strain data from fiber Bragg grating sensor and that from strain gauge at concrete hume pipe. We also get very good results for the long gauge displacement using fiber Bragg grating sensor which are identical to the data with short gauge length ordinary displacement sensor.

Effect of Cigarette Filter on Cytotoxicity Potential of Mainstream Smoke (담배주류연의 세포독성에 대한 담배필터의 영향)

  • Shin Han-Jae;Sohn Hyung-Ok;Han Jung-Ho;Park Chul-Hoon;Hur Jae-Yeon;Lee Dong-Wook;Hwang Keon-Joong;Hyun Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.51-58
    • /
    • 2005
  • The objective of this study was to evaluate the effect of cigarette filter on in vitro cytotoxicity of cigarette mainstream smoke from the cigarette. In this work, we used 3 types of cigarettes included non-filtered 2R4F cigarette, cellulose acetate-filtered 2R4F cigarette, and carbon dual-filtered 2R4F cigarette which was made from original 2R4F by replacing with an acetate filter containing carbon. The cytotoxicity of both the cigarette smoke condensate (CSC), which was collected in Cambridge filter pad, and the gas/vapor phase (GVP), which was bubbled through in phosphate-buffered saline in a gas-washing bottle, was determined using a neutral red uptake assay with CHO-K1 cells. With regard to cytotoxicity when calculated on an equal puff basis, the cytotoxicity of CSC from the filtered cigarettes was lower than that of the non filtered cigarette. Also, $EC_{50}$ vlaue of GVP from carbon filter cigarette was 40.9 puff/L, indicating the cytotoxicity to be $20\%$ lower than that of the CA filter cigarette. The cytotoxicity of the GVP was correlated to the several vapor phase components (formaldehyde, acetaldehyde, acetone, acrolein, crotonaldehyde and MEK). In conclusion, carbon filter, which significantly reduced the amount of carbonyl compounds in mainstream cigarette smoke, results in significant reductions in the cytotoxicity potential of the smoke.

The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy (Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가)

  • Goo, Jang Hyeon;Won, Hui Su;Hong, Joo Wan;Chang, Nam Jun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.363-368
    • /
    • 2014
  • Purpose : The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Materials and Methods : Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with $TrueBeam^{TM}$ STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. Results : In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. Conclusion : According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

FUZZY QUOTIENT STRUCTURES OF BCK-ALGEBRAS INDUCED BY FUZZY BCK-FILTERS

  • Jun, Young-Bae
    • Communications of the Korean Mathematical Society
    • /
    • v.21 no.1
    • /
    • pp.27-36
    • /
    • 2006
  • In this paper, we establish a generalization of fundamental homomorphism theorem in BCK-algebras by using fuzzy BCK-filters. We prove that if ${\mu}$. (resp. v) is a fuzzy BCK-filter of abounded BCK-algebra X (resp. Y), then $\frac{X{\times}Y}{{\mu}{\times}v}{\approxeq}X/{\mu}{\times}Y/v;\;and\;if\;{\mu}$ and F is a BCK-filter in a bounded BCK-algebra X such that $F/{\mu}$ is a BCK-filter of $X/{\mu}$, then $\frac{X/{\mu}}{F/{\mu}}{\approxeq}X/F$.

A Study of Filtralite Media Applicability for Development F/A Process of Membrane Filtration Pre-treatment Process in the Water Purification Plant (정수장에서 막여과 전처리용 F/A 공정 개발을 위한 Filtralite 여재의 적용성 연구)

  • Kim, JUN-Hyun;Jun, Yong-sung;Kwak, Young-ju;Jang, Jung Woo
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.503-514
    • /
    • 2015
  • In this study, water purification system without coagulant was consisted of F/A and membrane to produce purified water which only uses physical treatment without coagulant. Because the use of coagulant has a possibility remaining of hazardous aluminum with our health. Especially, the Filtralite was reviewed the possibility to remove turbidity and organic material. It was found that the turbidity removal rate of Filtralite was 83~84%. It show that Filtralite has similar efficiency to sand-filter. But Filtralite has higher 50% removal rate of organic material than sand-filter due to well-developed pore on the surface of it. So, Filtralite could be used to substitute the sand-filter for the F/A process due to higher removal rate. And also coupled with activated carbon in F/A process, TMP was increased by TOC value. To prevent increasing TMP, media that has outstanding organic adsorption ability should be used.