• Title/Summary/Keyword: extreme heat

Search Result 254, Processing Time 0.03 seconds

Heat transfer of Mixed convection in rectangular space with constant heat flux (일정 열유속의 열원을 갖는 사각공간의 혼합대류 열전달)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.552-558
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room numerical simulation with a standard k-$\varepsilon$model was carried out. In the present study the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with a downward angle depresses recirculation flow causing a strong stream in the wider space of the room Ventilation and removal of the released heat are promoted with this pattern, There is a possibility of local extreme heating at the upper surface of the engine when supply and exhaust ports of air are in bilateral symmetry.

  • PDF

The Experimental Assessment of Influence Factors on KLS-1 Microwave Sintering (한국형 인공월면토(KLS-1) 마이크로파 소결에 미치는 영향인자에 관한 실험적 연구)

  • Jin, Hyunwoo;Lee, Jangguen;Ryu, Byung Hyun;Shin, Hyu-Soung;Kim, Young-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.2
    • /
    • pp.5-17
    • /
    • 2021
  • The Moon has been an attractive planet as an outpost for deep space exploration since He-3 and water ice which can be used as energy resources were discovered. In-Situ Resource Utilization (ISRU) construction material fabrication method is required for sustainable space planet exploration. In this paper, the possibility of microwave sintering technology for construction material fabrication was evaluated using lunar regolith that can be easily collected from the Moon surface. Experimental assessment of the influence factors on microwave sintering was conducted using a hybrid sintering system for efficient processing. The heat distribution in the furnace was observed using thermal paper that is coated with a material formulated to change color when exposed to heat. Based on this result, sintered cylindrical KLS-1s with a diameter of 1 cm and a height of 2 cm were fabricated. Densities were measured for the sintered KLS-1s under rotating turntable conditions that have an effect of microwave dispersion. The more dielectrics were arranged, the more microwaves were dispersed reducing the heat concentration, and thus a uniformity of sintered KLS-1s was enhanced.

Flow Distributions in the Channel of Plate Heat Exchanger Applied in Vacuum Evaporating Distiller System

  • Jin, Zhen-Hua;Park, Gi-Tae;Choi, Soon-Ho;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.389-394
    • /
    • 2008
  • Nowadays Plate Heat Exchanger (PHE) is widely used in different industries such as chemical, food and pharmaceutical process and refrigeration due to the efficient heat transfer performance, extreme compact design and efficient use of the construction material. In present work, PHE is applied in the fresh water generator system. Fresh water generators or desalinators are installed in ship to convert seawater to fresh water using heat from engines. PHE is an important part of a condensing or evaporating system. Among many of factors which should be concentrated on, the heat transfer and pressure drop is most important parts during sizing and rating the performance of PHE. Flow maldistribution is common but it will significantly reduce the heat exchanger performance. In this paper provide a overview of PHE cover basic of theory and conduct a numerical approach for flow distribution in plate channel. An experimental study on the performance of fresh water generator system which developed by plate heat exchanger will presented in future research. Thus, extensive experiment and analysis is required to study the thermal and fluid flow characteristics of PHE.

  • PDF

A Study on the Lubricational Characteristics of Automotive Piston Motions With $MoS_{2}$ and PTFE Coating Materials ($MoS_{2}$와 PTFE 코팅재료에 의한 자동차 피스톤 운동의 윤활특성 연구)

  • Oh, Seong-Mo;Mun, Sang-Don
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.57-62
    • /
    • 2007
  • The lubricational characteristics about friction wear has an effect on the material quality of surface. In this paper, we studied the lubricational characteristics through the surface modification experiment by spray coating the surface with $MoS_{2}$ and PTFE solid lubricants. In the case of $MoS_{2}$ and PTFE coating, the friction coefficient of Journal is lower than that for noncoating so the friction characteristics is excellent. In particular, the beginning characteristics of $MoS_{2}$ coating is excellent, and in the case of PTFE coating, seizure dose not appear seizure. $MoS_{2}$ and PTFE coating are excellent in the extreme pressure at high load. The wear characteristics is excellent in the following order; PTFE < $MoS_{2}$ < Non Coating. For Non coating, seizure appears at the beginning due to the heat, but in the case of $MoS_{2}$ and PTFE coating, it will have the excellent heat stability even at high temperature.

Study on Evaluation Analysis on Thermal Performance of Window Using A. S. Lab.(Artificial Solar Laboratory) (인공태양실험실(A. S. Lab.)을 활용한 창호의 열성능 평가에 관한 연구)

  • Kang, Ki-Nam;Lee, Keon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.812-819
    • /
    • 2010
  • Recently residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. Along this the increased size and transparency of window as well as light surface caused by high stories lowers the heat shield efficiency of building. Since glass that constitutes building surface has low heat efficiency, it aggravates heat loss of all building considerably, thereby resulting in extreme heating load and cooling load in the country where temperature varies much in summer and winter. The research will check whether experiment can be effectively done by overcoming the limit of existing artificial solar laboratory constructed in the country and properly adjusting controlled variables with simplified function through construction of this experimental set.

The Analysis of planning methode and case study for Model 'Climate Change Adaptation City' (기후변화 적응도시 모델개발을 위한 계획기법 및 사례 분석)

  • Kim, Jongkon
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.13-19
    • /
    • 2012
  • The Earth's surface temperature still continues to rise, and extreme weather phenomena such as heat waves, drought, and precipitation have been repeated every year. It is reported that international communities attribute the main cause of the Earth's surface temperature rise to the excessive use of the fossil energy. Recently, the damage caused by climate change is getting worse, and the place where we live is suffering the most. Cities have been continuously growing not only meeting the basic functions of human habitation, work and leisure but also being places for various economic and social activities. But Cities, the victims of climate change, have grown only considering human needs and convenience rather than predicting their physical and ecological systems(Albedo effects, urban microclimate, resources and energy of the circulatory system, etc). In other words, the cities offer the cause of the problems of climate change, and even worsen the extreme weather phenomena without coping with them. Therefore, it is urgent priorities to protect the climate, to prevent the causes of the extreme weather phenomena and to enhance the adaptive capacity for the worse weather events. This study is to derive the concept for adapting to these climate changes which can make cities escape from exposure to these climate change impacts and make themselves safer places to live. And it analyzes some European cities and present developing models to implement planning methods. In this study, the concept of the climate adaptive cities will be suggested to prepare the adaptation measures for urban planners, and climate change adaptation models will be presented by analyzing some preliminary cases.

Heating Performance Evaluation of the VRF Heat Pump System with Refrigerant Heating Cycle for the Extreme Cold Region (냉매 가열식 대용량 VRF 히트펌프 사이클 설계를 통한 극한랭지 난방 성능 평가)

  • Lee, Sang-Hun;Choi, Song;Kim, Byeng-Soon;Lee, Jae-Keun;Lee, Kang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.571-579
    • /
    • 2011
  • Heat pump systems for commercial building with variable refrigerant flow(VRF) are expanding a market due to high energy efficiency, lower maintenance cost and easy installation comparing with the conventional heat pump with the constant refrigerant flow. In general, heat pump systems degrade the energy efficiency in the extremely low temperature regions. In this study, VRF heat pump system with refrigerant heating is experimentally investigated to overcome the low heating performance in the extremely low temperature regions. VRF heat pump system with refrigerant heating is found out the sufficient heating performance in the -25 degree temperature condition comparing with the conventional heat pump system and is obtained more than 2,500 kPa high pressure in the evaporator at low temperature.

Heat Analysis for Heat Sink Design Using Finite Element Method (유한요소법을 이용한 방열판 설계를 위한 열해석)

  • Jang, Hyun-Suk;Lee, Joon-Seong;Park, Dong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1027-1032
    • /
    • 2013
  • LED is standing in the limelight as a light part of the low-carbon green energy. While LEDs are eco-friendly, efficient and durable, extreme heat rises can cause their durability to decrease, with 80% of the power supply being turned into heat energy. Heat radiation systems are important because rising temperatures affect the lifetime of LED elements. Therefore, in this paper, thermal analysis was performed for the shape of heat sink to the LED bulb. Also, it is applied the temperature control systems to our products for optimal performance.

Characteristics of daily mortality due to heat waves in Busan in July 1994 (1994년 7월 부산지역의 폭염으로 인한 일 사망률 특성 연구)

  • Lee, Dae-Geun;Kim, Jiyoung;Cho, Byoung-Cheol
    • Atmosphere
    • /
    • v.17 no.4
    • /
    • pp.463-470
    • /
    • 2007
  • This study aims to assess the impact of the hot summer weather on daily mortality in Busan. Daily total all-caused mortality in the entire population in Busan has been examined during 1991-2005. The daily deaths were standardized to account for the long-term trend in mortality and their seasonal and weekly cycles. We found the net increase (about 8.2%) of excess deaths during the extraordinary heat wave period in July of 1994. It corresponds to the excess deaths of 109.5 during the month. The abnormality of temperature extremes in July of 1994 and their impacts on human health were also investigated. Unusual heat wave appeared in the first ten days in July of 1994. The excess deaths are likely to be attributable to the record-breaking heat waves. The result suggests that unusual early heat waves would be dangerous, even for inhabitants who live in an acclimated region to the heat waves such as Busan.

Sea Surface Temperature Time Lag Due to the Extreme Heat Wave of August 2016 (2016년 8월 폭염에 따른 표층수온의 지연시간 고찰)

  • Kim, Ju-Yeon;Han, In-Seong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.677-683
    • /
    • 2017
  • In this study, we examined responses to Sea Surface Temperature (SST) as the result of an intensive heat wave that took place in August 2016 and the cross correlation between SST and Air Temperature (AT) in August 2016. The data used included the SST of 8 ocean buoys, provided by the National Institute of Fisheries Science, and the AT of AWS near those 8 ocean buoys recorded every hour. To identify an appropriate data period, on FIR filter was applied. Two locations in the south sea were selected to be observed over similar a period, with a high correlation coefficient of about 0.8 and a time lag of about 50 hours between AT and SST. For the yellow sea, due to shallow waters and tidal currents, SST showed a rapid response caused by changes in AT. The east sea showed a negative correlation between AT and SST because of significant water depth and marine environment factors. By identifying the time lag between AT and SST, damage to aquatic organisms can be minimized, and we expect to develop a rapid response system for damage to the fishery industry caused by extreme heat waves.