• 제목/요약/키워드: extreme cold weather

검색결과 38건 처리시간 0.035초

RCP 시나리오 기반 WRF를 이용한 CORDEX-동아시아 2단계 지역의 가까운 미래 극한기온 변화 전망 (Near Future Projection of Extreme Temperature over CORDEX-East Asia Phase 2 Region Using the WRF Model Based on RCP Scenarios)

  • 서가영;최연우;안중배
    • 대기
    • /
    • 제29권5호
    • /
    • pp.585-597
    • /
    • 2019
  • This study evaluates the performance of Weather Research and Forecasting (WRF) model in simulating temperature over the COordinated Regional climate Downscaling EXperiment-East Asia (CORDEX-EA) Phase 2 domain for the reference period (1981~2005), and assesses the changes in temperature and its extremes in the mid-21st century (2026~2050) under global warming based on Representative Concentration Pathway (RCP) scenarios. MPI-ESM-LR forced by two RCP scenarios (RCP2.6 and RCP8.5) is used as initial and lateral boundary conditions. Overall, WRF can capture the observed features of temperature distribution reflecting local topographic characteristic, despite some disagreement between the observed and simulated patterns. Basically, WRF shows a systematic cold bias in daily mean, minimum and maximum temperature over the entire domain. According to the future projections, summer and winter mean temperatures over East Asia will significantly increase in the mid-21st century. The mean temperature rise is expected to be greater in winter than in summer. In accordance with these results, summer (winter) is projected to begin earlier (later) in the future compared to the historical period. Furthermore, a rise in extreme temperatures shows a tendency to be greater in the future. The averages of daily minimum and maximum temperatures above 90 percentiles are likely to be intensified in the high-latitude, while hot days and hot nights tend to be more frequent in the low-latitude in the mid-21st century. Especially, East Asia would be suffered from strong increases in nocturnal temperature under future global warming.

우리나라 겨울철 극한저온현상 발생 시 종관 기후 패턴 (Synoptic Climatic Patterns for Winter Extreme Low Temperature Events in the Republic of Korea)

  • 최광용;김준수
    • 대한지리학회지
    • /
    • 제50권1호
    • /
    • pp.1-21
    • /
    • 2015
  • 본 연구에서는 지난 40년 동안(1973~2012)의 우리나라 기상청 산하 61개 지점 일기온 자료와 NCEP/NCAR 재분석 자료를 바탕으로 우리나라 지역별 겨울철 극한저온현상 발생 시 동아시아 영역의 종관 기후 패턴의 특징을 밝히고자 하였다. 일최고기온과 일최저기온 하위 10 퍼센타일 기준으로 정의된 겨울철 극한저온현상은 주로 겨울철 전반기(12월 초순~1월 중순)에 2~7일 간격으로 우리나라 전역 또는 주요 산맥 기준 동서지역으로 구분되어 발생함을 알 수 있다. 해수면기압과 바람벡터 등의 지상 종관 자료 합성장 분석에 따르면 총 13개로 구분되는 우리나라 겨울철 극한저온현상 발생 공간 패턴은 산맥뿐만 아니라 시베리아 고기압과 알류샨 저기압의 상대적인 확장 범위와 강도와 밀접한 관련성이 있음을 알 수 있다. 대류권 중층(500 hPa) 종관기후도 분석에 따르면, 블러킹 형태의 저기압이 상층 찬 공기를 고위도 지역에서 한반도로 이류시킬 때 우리나라에 겨울철 극한저온현상이 발생하기에 적합한 조건이 형성됨을 알 수 있다. 이러한 결과들은 지역규모 이상의 동아시아 겨울철 극한저온현상 예보를 향상시키기 위해 시베리아 고기압, 알류샨 저기압, 상층 블러킹 등의 종관 기후 요소를 모니터링하는 것이 중요함을 가리킨다.

  • PDF

우리나라 기후 절기별 기온 변화의 시공간적 특성 분석 (Temperature Changes of Climatic Solar Terms and Their Spatiotemporal Characteristics in South Korea)

  • 진미정;박선엽
    • 대한지리학회지
    • /
    • 제50권1호
    • /
    • pp.23-36
    • /
    • 2015
  • 본 연구는 계절변화를 표현하기 위해 실생활에서 흔히 사용되는 기후 절기의 기온 변화 패턴을 파악하고 실제 기상 현상과의 부합도를 분석하고자 하였다. 전국 61개 관측소 자료를 통한 분석 결과, 관측지점 평균 기온이 증가할수록 연중 기온변화 파형의 정점에 해당하는 극서기중심이 7월 21일에서 8월 5일, 즉 절기적으로 입추 쪽으로 이동하였다. 주요 기후 절기인 대서, 상강, 대설, 대한을 중심으로 살펴 본 절기부합도는 전체적으로 낮을 뿐만 아니라 지역적 차이도 뚜렷하게 나타났다. 대부분 관측소에서 각 절기에 해당하는 기상 현상은 현저히 늦게 나타났는데, 각 절기일 기준 1주 이내로 관측된 경우는 전체의 7.7~40.4%에 머물렀다. 대서, 상강, 대설의 절기부합도는 동서 방향으로 차이를 보였고, 절기부합도가 비교적 높게 나타난 대한에는 동서 간의 차이보다는 남북 방향의 위도 조건이 절기부합도 변화 패턴에 영향을 주었다. 절기별 기온변화 경향과 속도가 지역적으로 균일하지 않다는 점을 고려한다면, 개별 절기의 배열과 각 절기 간 시간 간격에 대한 조정을 고려함으로써 24절기의 현실적 유용성을 제고할 수 있을 것으로 본다.

  • PDF

혹한기 광산배수 처리 공정 내 황산염 환원 박테리아의 활성 증진을 위한 발광다이오드의 이용 제안 (Use of Light Emitting Diode for Enhanced Activity of Sulfate Reducing Bacteria in Mine Drainage Treatment Process Under Extreme Cold)

  • 최유진;최연우;이안나;김경웅
    • 자원환경지질
    • /
    • 제50권3호
    • /
    • pp.251-256
    • /
    • 2017
  • 본 연구는 폐광산에서 배출되는 산성광산배수가 하천수 및 지하수에 유출되면서 발생되는 환경 오염들을 막기 위해 생물학적 자연정화 처리 방법인 연속적 알칼리도 생성 시스템의 효율을 증대 시키는 방안에 관한 연구이다. 연속적 알칼리도 생성 시스템를 이용한 산성광산배수의 처리는 대부분 황산염 환원 박테리아를 이용한 생물학적 처리 기술이며, 실제 현장 적용실험에서 그 효과가 증명되었고, 광산배수 정화 사업에 적용하도록 개발된 사례가 많다. 그러나 계절적인 온도 저하로 기온이 매우 낮은 겨울이나 초봄 동안에는 황산염 환원 박테리아가 생존은 가능하더라도 황산염을 환원시키는 활동이 거의 멈추게 되어 지속적인 산성광산배수 처리 효율에 문제점을 야기한다. 본 연구에서는 연속적 알칼리도 생성 시스템에 발광 다이오드를 접목하여 유기물 층의 황산염 환원 박테리아 활성을 증진시키고, 온도가 낮은 겨울철에도 발광 다이오드의 발열 효과를 이용하여 활성 온도를 유지 할 수 있는 방안을 제안한다. 더불어, 산성광산배수 처리 시설은 전력을 쉽게 공급할 수 없는 곳에 위치한 지리적인 특성을 고려하여, 발광 다이오드에 전원을 공급할 수 있는 전원 공급 장치로 태양 전지 모듈 사용을 제안한다. 본 방법을 통하여 추가적 연구들이 진행된다면, 태양광 에너지와 발광 다이오드를 융합한 친환경적인 방법을 이용하여 겨울철에도 산성광산배수 처리 기술의 효율을 극대화 할 수 있을 것이다.

Outbreaks of Yuzu Dieback in Goheung Area: Possible Causes Deduced from Weather Extremes

  • Kim, Kwang-Hyung;Kim, Gyoung Hee;Son, Kyeong In;Koh, Young Jin
    • The Plant Pathology Journal
    • /
    • 제31권3호
    • /
    • pp.290-298
    • /
    • 2015
  • Starting in 2012, severe diebacks usually accompanied by abundant gum exudation have occurred on yuzu trees in Goheung-gun, Jeonnam Province, where severely affected trees were occasionally killed. On-farm surveys were conducted at 30 randomly-selected orchards located at Pungyang-myeon, Goheung-gun, and the resulting disease incidences were 18.5% and 39.6% for dieback and gumming symptoms, respectively. Black spots on branches and leaves also appeared on infected trees showing a typical dieback symptom. Morphological and molecular identifications of the isolated fungal organisms from lesions on the symptomatic leaves and branches revealed that they are identical to Phomopsis citri, known to cause gummosis. In order to find the reason for this sudden epidemic, we investigated the weather conditions that are exclusively distinct from previous years, hypothesizing that certain weather extremes might have caused the severe induction of pre-existing disease for yuzu. There were two extreme temperature drops beyond the yuzu's cold hardiness limit right after an abnormally-warm-temperature-rise during the winter of 2011-12, which could cause severe frost damage resulting in mechanical injuries and physiological weakness to the affected trees. Furthermore, there was an increased frequency of strong wind events, seven times in 2012 compared to only a few times in the previous years, that could also lead to extensive injuries on branches. In conclusion, we estimated that the possible damages by severe frost and frequent strong wind events during 2012 could cause the yuzu trees to be vulnerable to subsequent fungal infection by providing physical entries and increasing plant susceptibility to infections.

혹서기 무창계사에서 육계의 혈액지질 및 짧은 사슬지방산에 관한 역전점등과 냉각수 효과 (Effect of cooling water and inverse lighting on short chain fatty acid and blood lipid of broiler chickens in closed poultry house during hot weather)

  • 박상오;박병성;황보종;최희철
    • 한국응용과학기술학회지
    • /
    • 제31권1호
    • /
    • pp.31-43
    • /
    • 2014
  • This experiment evaluated the interaction effect of extreme heat diet(EHD), inverse lighting, and cool water on the growth performance of broiler chickens under extreme heat stress. There were 4 experimental groups (T1: EHD 1, 10:00-19:00 dark, 19:00-10:00 light, cold water $9^{\circ}C$; T2: EHD 2, 10:00-19:00 dark, 19:00-10:00 light, cold water $9^{\circ}C$; T3: EHD 1, 09:00-18:00 dark, 18:00-09:00 light, cold water $14^{\circ}C$; T4: EHD 2, 09:00-18:00 dark, 18:00-09:00 light, cold water $14^{\circ}C$), each group composed of 25 broilers and the experiment was repeated 3 times. EHD 1 contained soybean oil, molasses, methionine and lysine. EHD 2 contained all nutrients of EHD 1 and vitamin C additionally. As a result, T1 and T2 displayed higher body weight increase and diet intake compared to T3 and T4 (p<0.05). The weights of their liver and gizzard were similar but the weights of the thymus and bursa F were higher for T1 and T2 compared to that of T3 and T4 (p<0.05). It was observed that T1 and T2 displayed higher concentrations of blood triglyceride, total cholesterol, HDL-C and blood sugar compared to that of T3 and T4 but LDL-C level was higher for T3 and T4 compared to that of T1 and T2 (p<0.05). T1 and T2 displayed higher levels of immunity substances such as IgG, IgA and IgM compared to T3 and T4 but the blood level of corticosterone displayed to be lower for T1 and T2 compared to T3 and T4 (p<0.05). The T1 and T2 contained a higher amount of fecal lactobacillus compared to that of T3 and T4 but the T3 and T4 contained a higher amount of fecal E. coli, total aerobic bacteria, coliform bacteria compared to that of T1 and T2 (p<0.05). T1 and T2 displayed higher concentrations of cecal acetic acid, propionic acid and total short chain fatty acids compared to T3 and T4 but T3 and T4 displayed higher concentrations of butyric acid, isobutyric acid, valeric acid and isovaleric acid compared to T1 and T2 (p<0.05). These results have been observed that broiler chickens exposed to extreme heat stress with feeding EHD, inverse lighting and cold water would improve blood lipid, and elevate the production of immunity substance, beneficial microorganisms, and short chain fatty acids. This provision would also reduce the blood sugar consumption rate as energy sources and these effects will improve the growth performance of the broilers exposed to extreme heat.

개폐식 방사형 케이블 지붕 시스템의 역학적 특성 (Mechanical Characteristics of Retractable Radial Cable Roof Systems)

  • 박강근;이동우;최동일
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.21-32
    • /
    • 2017
  • The objective of this study is to analysis the mechanical characteristics on the geometric nonlinear behavior of radial cable roof systems for long span retractable cable roof structures. The retractable roof is designed as a full control system to overcome extreme outdoor environments such as extreme hot or cold weather, strong wind or sunlight, and the cable roof greatly can reduce roof weight compared to other rigid structural system. A retractable cable roof system is a type of structures in which the part of entire roof can be opened and closed. The radial cable roof is an effective structural system for large span retractable roofs, the outer perimeter of the roof is a fixed membrane roof and the middle part is a roof that can be opened and closed. The double arrangement cables of a radial cable truss roof system with reverse curvature works more effectively as a load bearing cables, the cable system can carry vertical load in up and downward direction. In this paper, to analyze the mechanical characteristics of a radial cable roof system with central posts, the authors will investigate the tensile forces of bearing cables, stabilized cables, ring cables, and the deflection of roof according to the height of the post or hub that affects the sag ratio of cable truss. The tensile forces of the cables and the deflection of the roof are compared for the cases when the retractable roof is closed and opened.

기후변화에 따른 공공기관 건축물의 리스크평가 (Risk Assessment of Public Agencies' Buildings due to Climate Change)

  • 최윤철
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.3-10
    • /
    • 2017
  • Climate change not only has various impacts such as human shoes, economics, the environment, industry, etc. but the damage caused by this is also increasing, it is expected that severe damage will not occur without efforts to respond to climate change ing. Therefore, as the impact of climate change like the extreme weather phenomenon is dailyized and its strength tends to become stronger, as much as the mitigation measures of climate change, as a comparative effort to reduce the negative impact of climate change, adaptation to climate change is necessary. Especially when the damage caused by climate change (intense heat, torrential rain, cold wave and heavy snow etc.) as an institution responsible for the provision of public services such as public institutions, the socio-economic spread to the nation and the people The effect is very large. We confirmed the level of response to climate change for the entire public institution, and selected climate change risk which is relatively important for specific facilities and business establishments of public institutions, climate change adaptation measures We will try to utilize it as basic material of establishment.

단열양생재 변화 및 열선 전력용량 차이에 따른 슬래브 콘크리트의 온도이력 특성 (Characteristic of Temperature History of Slab concrete by the Change of Insulation Curing Material and Difference of Heated cable Power Capacity.)

  • 정은봉;안상구;정상현;고경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.334-336
    • /
    • 2013
  • In this study, the temperature history was evaluated for the improved bubble sheets combining hot wires and PE films, which were developed under the extreme environmental condition of -10℃ and applied on the top surface of slab to prevent initial damage by freezing. Results can be summarized as follows. If improved bubble sheets combining hot wires with different capacity on double and quadruple bubble sheets are used, the temperature history for all materials decreased to 2~3℃ below zero but all test materials except Type 1 secured the accumulative temperature of 45° D·D at 7 days of material age, required for the prevention of initial freezing damage. This indicates the bubble sheets can prevent the initial damage by freezing.

  • PDF

정보 시스템 기술을 적용한 제설장비 운영 사례 분석 (Operation Case Analyses of Snow Removal Equipments using Information system Technologies)

  • 김희재;김근영
    • 한국재난정보학회 논문집
    • /
    • 제14권2호
    • /
    • pp.154-164
    • /
    • 2018
  • 연구목적 : 최근 기후변화에 따라 여름철 태풍, 호우와 겨울철 대설, 한파 등의 기상재난이 증가하고 있다. 대설재난은 교통, 건물, 시설물 등에 다양한 피해를 발생시키기 때문에 신속한 대처가 필요하다. 대설재난이 도시 안전에 영향을 주고 있으나 우리나라의 대설재난 대처는 미흡하고, 정책 연구도 부족한 상황이다. 연구방법 : 본 연구는 대설재난이 발생할 때 신속한 도로 제설을 위하여 제설차량과 장비에 정보 통신 기술을 활용한 사례를 분석하고, 시사점을 도출한다. 연구결과 : 도로 제설장비에 정보통신기술이 적용된 장비를 부착하면 긴급 상황시 제설차량과 장비의 위치를 파악하여 인근지역의 도로 제설을 응원할 수 있다. 결론 : 본 연구의 사례 분석은 향후 지자체 제설장비의 효율적 이용을 위해 활용될 수 있다.