• Title/Summary/Keyword: extraction resin

Search Result 155, Processing Time 0.026 seconds

A Study on the Development of Analytical Method for Micro-odorous Compounds in Water (흡착제를 이용한 수중의 미량 이취물질 분석법 개발에 관한 연구)

  • Kim, Eun-Ho;Son, Hee-Jong;Kim, Yeong-Ung;Kim, Hyeong-Seok;Sung, Nak-Chang
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.103-107
    • /
    • 1999
  • Even if odorous compounds remain very low concentration in water, it cause strong odor. Because Geosmin and most of odorous compound had very low vaporization, those were difficult to analyze with GC/MSD and Purge & Trap. So, we needed pre-treatment method for decreasing amounts of extracting solvents, improving recovery efficiencies and increasing analytical efficiencies. This study developed efficient technology for analyzing odorous compounds, using various adsorbents and extracting solvents. The optimum adsorbent was XAD resins. Especially, XAD-2, XAD-7 and XAD-2010 were superior, but XAD-2 of these and the optimum extraction solvent is MTBE. Other extraction solvents' efficiency is in order of MTBE>Dichloromethane>n-Hexane>Diethylether. The optimum NaCl dosage for increasing efficiency is 5 g in liquid-liquid extraction method. The shaking time(0~24hr) has no concern with adsorption efficiency. The optimum adsorbent is XAD-2 resin and extraction solvent is MTBE. Dosing NaCl, adsorption efficiency is increased in liquid-liquid extraction method, but NaCl has no effect on liquid-solid extraction method. In this experimental results, this algae toxins(Mycrocystin, Anatoxin etc.).

  • PDF

A Study on the Development of Analytical Method for Micro-Odorous Compounds in Water (흡착제를 이용한 수중의 미량 이취물질 분석법 개발에 관한 연구)

  • 김은호;성낙창;최용락
    • Journal of Life Science
    • /
    • v.9 no.5
    • /
    • pp.575-580
    • /
    • 1999
  • Even if odorous compounds remained very low concentration in water, it caused strong odor. Because Geosmin and most of odorous compound had very vaporization, those were difficult to analyze with GC/MSD and Purge & Trap. So, we needed pre-treatment method for decreasing amounts of extracting solvents, improving recovery efficiencies and increasing analytical efficiencies. This study developed efficient technology for analyzing odorous compounds, using various adsorbents and extracting solvents. The optimum adsorbent was XAD resins. Especially, XAD-2, XAD-7 and XAD-2010 were superior, but XAD-2 of these and MTBE was the optimum extraction solvent. Other extraction solvent's efficiency was in order of MTBE>Dichloromethane>n-Hexane>Diethylether. The optimum NaCl dosage for increasing efficiency was 5g in liquid-liquid extraction method. The shaking time(0∼24hr) had no concern with adsorption efficiency. The optimum adsorbent was XAD-2 resin and extraction solvent was MTBE. Dosing NaCl, adsorption efficiency was increased in liquid-liquid extraction method, but NaCl has no effect on liquid-solid extraction method. In this experimental results, this method will apply to not only Geosmin but other well-known odorous compounds (2-MIB, IBMP, IPMP, TCA) and algae toxins (Mycrocystin, Anatoxin etc)

  • PDF

Surgical extrusion of immature permanent tooth with crown-root fractures: a case report with 36-month follow up (외과적 정출술을 이용한 치관-치근 파절된 미성숙 영구치의 치료: 3년 간의 증례보고)

  • Jeon, Su-jin
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.679-688
    • /
    • 2019
  • A 8-year-old patient presented with a crown-root fracture of the maxillary right central incisor with an oblique subgingival fracture line. A multidisciplinary treatment approach including endodontic treatment, surgical extraction and intraalveolar repositioning was used to gain sufficient crown length of the fractured maxillary incisor. The coronally repositioned maxillary right central incisor was stabilized by a resin wire splint. Apexification using MTA was performed. Resin core and direct resin restoration(Cl IV) on fractured teeth was built up. Clinical and radiographic follow-up of the maxillary right central incisor after 36 months showed no signs of root resorption or pathology and acceptable aesthetics and functions were maintained. Surgical extrusion can be considered as a good treatment modality for young patients.

  • PDF

Analysis on the Generation Characteristics of $^{14}C$ in PHWR and the Adsorption and Desorption Behavior of $^{14}C$ onto ion Exchange Resin (중수로 원전$^{14}C$ 발생 특성 및 이온교환수지에 의한 $^{14}C$$\cdot$착탈 거동 분석)

  • 이상진;양호연;김경덕
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.147-157
    • /
    • 2004
  • The production of $^{14}C$ occurs in the Moderator(MOD), Primary Heat Transport System (PHTS), Annulus Gas System(AGS) and Fuel in the CANDU reactor. Among the four systems, The MOD system is the largest contributor to $^{14}C$ production(approximately 94.8%). $^{14}C$ is distributed of $^{14}CO_2$, $H_2^{14}CO_3$, $H^{14}{CO_3}^-$ and $^{14}{CO_3}^{2-}$ species as a function of the pH of water. Of these species, $H_2^{14}CO_3$ and $H^{14}{CO_3}^-$ form are predominant because the pH of MOD system is > 5. In this paper, adsorption-desorption characteristics of bicarbonate ion (${HCO_3}^-$) by IRN 150 resin was investigated. ${HCO_3}^-$ ion existed in neutral condition(app. pH 7)was reacted with ion exchange resin (IRN-150) and saturated with it. Then $NaNO_3$ and $Na_3PO_4$ solutions selected as extraction materials were used to make an investigation into feasibility of ${HCO_3}^-$ extraction from resin saturated with ${HCO_3}^-$. Desorption of $CO^{2+}$ and $Cs^+$ ion by $Na^+$ ion was not occurred, and desorption of ${HCO_3}^-$ ion by ${NO_3}^-$ and ${PO_4}^{3-}$ was occurred slowly. Also, the status of ion exchange which is used in Wolsong NPPs and generation of spent resin yearly were surveyed.

  • PDF

Separation of Aluminum and Iron from Platinum Mixture using Synthetic Extraction Resins (합성(合成) 추출(抽出) 수지(樹脂)를 이용(利用)한 백금용액(白金溶液)으로부터 알루미늄과 철(鐵)의 분리(分離))

  • Lim, Gwang-Il;Han, Dong-Hyuk;Hwang, In-Sung;Han, Choon;Lee, Jin-Young;Kim, Joon-Soo;Park, Hyung-Kyu
    • Resources Recycling
    • /
    • v.20 no.3
    • /
    • pp.68-76
    • /
    • 2011
  • For the separation of aluminum and iron from platinum mixtures, extraction resins were synthesized and separation efficiencies were compared with those by commercial one, $P_{204}$. During synthesis, the suspension polymerization method was adopted with D2EHPA as an extractant. Also, benzoyl peroxide as a starter was divided into 3parts and injected for the uniform size and dispersion of resin particles. Comparison tests resulted in 100% separation of Fe and Pt for both synthetic and $P_{204}$ resins. In case of Al and Pt, synthetic and $P_{204}$ resin gave extraction efficiencies of 99.9% and 98.9%, respectively. Difference in extractant contents of synthetic resin(61.8%) and $P_{204}$(60%) was considered to give differences in separation efficiencies of aluminum and iron elements. For both resins, separation efficiencies of Al and Fe increased up to $55^{\circ}C$. According to FT-IR analyses of both resins, specific peaks of D2EHPA and crosslinked polystyrene were identified at the wavenumber of $1000cm^{-1}$ and $2900cm^{-1}$ respectively.

A Study on the Analytical Method of Trace Metal Ions in Sea Water by Inductively Coupled Plasma - Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 해수중 미량금속의 분석에 관한 연구)

  • Lee, Won;Park, Kyung-Su;Kim, Eun Kyung;Hur, Young-Hoe
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.499-504
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in sea water has been investigated by Inductively Coupled Plasma-Mass Spectrometry. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Recoveries of 99.8% for Cu, 99.6% for Sn, and 97.9% for Bi were obtained for the standard spiked sample. The developed method was applied to analysis of trace metals in sea water.

  • PDF

Separation of Light Rare-Earth Elements Using Gas-Pressurized Extraction Chromatography

  • Kim, Namuk;Park, Jai Il;Um, Wooyong;Kim, Jihye
    • Mass Spectrometry Letters
    • /
    • v.12 no.4
    • /
    • pp.186-191
    • /
    • 2021
  • A new method for chemical separation of light rare-earth elements (LREEs) using gas-pressurized extraction chromatography (GPEC) is described. GPEC is a microscale column chromatography system that features a constant flow of solvents, which is created by pressurized nitrogen gas. The separation column with a Teflon tubing was packed with LN resin. The proposed GPEC method facilitates production of lesser chemical wastes and faster separation owing to the use of low solvent volume compared to traditional column chromatography. We evaluated the separation of Ba, La, Ce, and Nd using various elution solvents. The column reproducibility of the proposed GPEC system ranged from 2.4% to 4.9% with RSDs of recoveries, and the column-to-column reproducibility ranged from 3.1% to 6.3% with RSDs of recoveries. The proposed technique is robust, and it can be useful for the fast separation of LREEs.

Evaluation of DNA Extraction Methods from Low Copy Number (LCN) DNA Samples for Forensic DNA Typing

  • Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.15 no.3
    • /
    • pp.229-232
    • /
    • 2009
  • DNA isolation for PCR-based short tandem repeat (STR) analysis is essential to recover high yields of amplifiable DNA from low copy number (LCN) DNA samples. There are different methods developed for DNA extraction from the small bloodstain and gloves, commonly found at crime scenes. In order to obtain STR profiles from LCN DNA samples, DNA extraction protocols, namely the automated $iPrep^{TM}$ $ChargeSwitch^{(R)}$ method, the automated $QIAcube^{TM}$ method, the automated $Maxwell^{(R)}$ 16 DNA $IQ^{TM}$ Resin method, and the manual $QIAamp^{(R)}$ DNA Micro Kit method, were evaluated. Extracted DNA was quantified by the $Quantifiler^{TM}$ Human DNA Quantification Kit and DNA profiled by $AmpFISTR^{(R)}$ $Identifiler^{(R)}$ Kit. Results were compared based on the amount of DNA obtained and the completeness of the STR profiles produced. The automated $iPrep^{TM}$ $ChargeSwitch^{(R)}$ and $QIAcube^{TM}$ methoas produced reproducible DNA of sufficient quantity and quality trom the dried blood spot. This two automated methods showed a quantity and quality comparable to those of the forensic manual standard protocols normally used in our laboratory. In our hands, the automated DNA extraction method is another obvious choice when the forensic case sample available is bloodstain. The findings of this study indicate that the manual simple modified $QIAamp^{(R)}$ DNA Micro Kit method is best method to recover high yields of amplifiable DNA from the numerous potential sources of LCN DNA samples.

  • PDF

A Study on the Quantification and Chracterization of Endocrine Disruptor Bisphenoi-A Leaching from Epoxy Resin (에폭시 수지 용출물질에서의 내분비계장애물질 Bisphenol-A의 정량과 용출특성 파악)

  • Bae, Bumhan;Choi, Myoung-soo;Lim, Nam-woong;Jeong, Jae-hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.469-477
    • /
    • 2000
  • Bisphenol-A (BPA), a known endocrine disruptor, is a main building block of epoxy resin which is widely used as a coating agent in residential water storage tanks. Therefore, BPA leaching from the epoxy resin may have adverse effects on human health. The possibility of BPA leaching from three epoxy resins were tested with a modified KS D 8502 method at 20, 50, 75 and $100^{\circ}C$ in deionized water and the specified test water, respectively. BPA leached to the test water was identified using GC-MS and quantified with GC-FID after a sequential extraction and concentration. The results showed that BPA leaching has occurred in all three samples tested. The quantify of BPA leaching from unit area of epoxy resin coating was in the range of $10.677{\sim}273.120{\mu}g/m^2$ for sample A, 29.737~1734.045 for sample B and 52.857~548.778 for sample C depending on the test temperature, respectively. In general, the amount of BPA leaching increased as the water temperature increases. This result implies a higher risk of BPA leaching to drinking water during a hot summer season. In addition, microbial growth, measured by colony forming units, in epoxy coated water tanks was higher than that in a stainless steel tank suggesting that compounds leaching from epoxy resin may support the growth of microorganisms in a residential water holding tank.

  • PDF

Slow release of microencapsulated model compounds of insect pheromone using low molecular weight polyethylene and urea-formaldehyde resin (저분자량 polyethylene과 urea-formaldehyde 수지를 이용한 microencapsulation에 의한 곤충 페로몬의 model 화합물들의 slow release)

  • Kim, Jung-Han;Oh, Won-Taek;Kim, Yong-Jin
    • Applied Biological Chemistry
    • /
    • v.34 no.2
    • /
    • pp.110-116
    • /
    • 1991
  • As the model compounds, citral and n-octanol which possess similar characteristics and structures of low molecular weight insect pheromones and $({\pm})-5-hydroxy-4-methyl-heptan-3-one$ which shows the aggregation pheromones activity of the rice weevil and the maize weevil were microencapsulated with low molecular weight polyethylene(LMPE) and urea-formaldehyde resin as wall materials. The core materials were microencapsulated as small particles in LMPE and urea-formaldehyde resin polymers and the microencapsulated polymers were white powders. And the polymer made from urea-formaldehyde resin was better than that from LMPE as wall material. The slow releasing effect and the releasing patten of the microencapsulated core materials were examined by solvent extraction method and headspace sampling method. Citral and n-octanol and $({\pm})-5-hydroxy-4-methyl-heptan-3-one$ were release more than 40 days and 15 days, respectively. The releasing pattern of urea-formaldehyde resin microcapsules showed rather smooth decrease than that of LMPE and was maintained at steady level longer.

  • PDF