• 제목/요약/키워드: extraction rate constant

검색결과 71건 처리시간 0.02초

Degradation Kinetics of Three Veterinary Antibiotics in Composted and Stockpiled Manure

  • Kim, Sung-Chul;Yang, Jae-E.;Ok, Yong-Sik;Jung, Doug-Young;Carlson, Kenneth
    • 한국토양비료학회지
    • /
    • 제45권1호
    • /
    • pp.43-50
    • /
    • 2012
  • Two typical animal waste management practices, composting and stockpiling, were evaluated for their effect on the degradation of three veterinary antibiotics (VAs), chlortetracycline (CTC), tylosin (TYL), and monensin (MNS). The VAs were applied to horse manure plots subject to composting or stockpiling, and core samples were collected over a period of time. Selected buffer solutions were used to extract the VAs and analysis for concentration was conducted with solid phase extraction (SPE) followed by high performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS) technique. The VAs demonstrated rapid dissipation within ten days followed by a gradual decrease in concentration until the end of the experimental period (141 days). All three VAs degraded more rapidly in the composting samples than in the stockpiling samples, particularly between 20 and 60 days of the observation period. Degradation of the three VAs generally followed a first-order kinetic model, and a fitted model with a calculated rate constant was determined for each treatment. TYL in composting showed the fastest degradation, with a calculated rate constant of $0.91day^{-1}$; the slowest degradation was exhibited by MNS in stockpiling, with rate constant of $0.17day^{-1}$. Calculated correlation coefficients ranged from 0.89 to 0.96, indicating a strong correlation between measured concentrations and fitted values in this study. Although concentration of TYL in composting treatment showed below detection limit during the test period, this study suggests that composting can reduce animal waste contaminants prior to field application as fertilizer.

초임계 이산화탄소를 이용한 토코페롤 고함유 참기름 추출 (Supercritical $CO_2$ Extraction of Sesame Oil with High Content of Tocopherol)

  • 주영운;손민호;이주석;변상요
    • KSBB Journal
    • /
    • 제20권3호
    • /
    • pp.210-214
    • /
    • 2005
  • 초임계 유체를 이용하여 참기름을 생산하기 위한 기초연구로 참깨에 존재하는 천연항산화제인 $\gamma$-토코페롤을 고함유한 참기름에 대해 연구하였다. $\gamma$-토코페롤은 $\alpha$-토코페롤에 비해 비타민 E 효력은 약하긴 하나, 참깨의 리그난과 길항적으로 작용하면 생체내 잔존율이 높아져 $\alpha$-토코페롤처럼 과산화지질 생성을 억제한다고 한다. 참깨의 볶음온도와 시간, 초임계 유체의 압력과 온도 그리고 초임계 유체의 유속 변화 시 $\gamma$-토코페롤의 함량에 미치는 영향에 대해 연구하였다. 그 볶음 온도 변화 시 $200^{\circ}C$ 이후 $\gamma$-토코페롤의 농도가 거의 일정하게 유지되었고, $200^{\circ}C$에서 배전시간을 증가함으로써 약 1.13배 정도 $\gamma$-토코페롤의 농도가 증가되었다. 초임계 유체 추출 시 250 bar를 제외한 압력변화에 의해 $\gamma$-토코페롤의 농도는 거의 변화하지 않았다. 그러나 같은 온도에서 초임계 유체의 유속을 $1{\~}3 m{\ell}/L$로 변화시킴에 의해 $\gamma$-토코페롤의 농도가 1.1배${\~}$1.5배 증가되었는데, 이는 $\gamma$-토코페롤의 이 추출 메카니즘이 탈착보다는 확산에 의해 이뤄짐을 알 수 있었다. 이상의 결과를 토대로 기존 압출추출방법과 초임계 추출 방법을 비교한 결과 $\gamma$-토코페롤의 농도가 1.3${\~}$1.6배 증가함을 확인할 수 있었다.

분광광도법에 의한 Ni(Ⅱ)-8-Hydroxyquinolinate의 용매추출 반응속도론 (A Study on the Solvent Extraction Kinetics of Complex Nickel(Ⅱ) 8-Hydroxyquinolinate by Spectrophotometry)

  • 이흥락;오인경
    • 대한화학회지
    • /
    • 제36권4호
    • /
    • pp.540-545
    • /
    • 1992
  • Nickel(Ⅱ)-8-hydroxyquinolinate의 용매추출에 대한 반응속도와 메카니즘을 분광광도법으로 연구하였다. 유기상 chloroform에 있는 8-hydroxyquinoline(HOx) 농도와 물층의 pH값을 변화시켜 가면서 흡광도를 측정하였으며, 흡광도 데이터를 해석하여 반응속도가 oxine농도에 대하여는 1차, [$H^+$]에 대하여는 -1차임을 알 수 있었다. 따라서 추출 반응의 속도결정단계는 1 : 1 금속킬레이트인 $NiOx^+$의 생성단계이며, 속도식은 다음과 같다. -d[$Ni^{2+}$]/dt = k[Ni$^{2+}$][Ox$^-$]=k'[Ni$^{2+}$][HOx]$_0$/[H$^+$]. 이 식의 k'값은 log [Ni$^{2+}$]$_0$/[Ni$^{2+}$]$_t$와 시간을 도시한 기울기로부터 구하였으며, 속도상수 k값은 k' = k ${\times}$ K$_{HOx}$ / K$_{D,HOx}$를 써서 계산하였다. 온도에 따른 속도상수의 변화로부터 계산한 활성화에너지 $E_a$ = 6.26 kcal/mol이었고, 활성화 파라미터인 ${\Delta}$G$^{\neq}_{298}$ = 6.59 kcal/mol, ${\Delta}$H$^{\neq}_{298}$ = 5.67 kcal/mol, ${\Delta}$S$^{\neq}_{298}$8 = -3.09 eu/mol이었다.

  • PDF

태아심음주기의 검출을 위한 고해상 피치 검출 알고리즘 (High Resolution Pitch Determination Algorithm for Fetal Heart Rate Extraction)

  • 이응구;이두수
    • 전자공학회논문지B
    • /
    • 제31B권2호
    • /
    • pp.80-87
    • /
    • 1994
  • Fetal monitoring is a routine procedure to obtain a record of physiologic functions during pregnancy and labor. It is required to determine fetal heart frequency accurately. There are various types of fetal heart rate(FHR) determination and the most frequently applied method is transabdominal Doppler ultrasound. However, in the case of weak or noise corrupted Doppler ultrasound signals, conventional peak detections and the autocorrelation function method have many difficulties to determine FHR precisely. Also the autocorrelation function is effected by threshold level and window size. To solve these problems, the high resolution pitch determination algorinthm is introduced to detect FHR from Doppler ultrasound signals. This scheme digitally processes Doppler ultrasound signal for digital rectification, envelope detection, decimation and correlation calculation of two interconnected segments and then FHR is determined by its maximal value. Even in the case of a greatly smeared noise signal, this algorithm is able to search FHR more accurately than autocorrelation function by means of compensating FHR with a constant correlation threshold. This algorithm is simulated by 386-MATLAB on PC 486/DX and verified that it is superior to the autocorrelation function method.

  • PDF

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

정어리 지질의 추출속도에 관한 연구 (Studies on the Extraction Rate of Oil from Sardine, Sardinops melanosticta)

  • 양현석;이근태;변대석
    • 한국수산과학회지
    • /
    • 제17권1호
    • /
    • pp.40-46
    • /
    • 1984
  • 용매추출법에 의한 정어리 백색육중의 지질을 hexane으로 추출하여 추출속도 이론과의 연관성을 구명하고 또한 추출속도에 미치는 인자중 온도 및 수분함량의 영향을 검토한 결과는 다음과 같다. 1. 정어리 지질의 추출은 초기와 후기로 나누어지며 율속단계인 후기에서의 확산계수를 구하기 위하여 Fick의 비정상 상태 확산이론을 적용시키는 것은 가능하다. 2. $30^{\circ}C,\;45^{\circ}C,\;60^{\circ}C$의 추출온도에서 이론과의 연관성이 가장 좋았던 것은 $30^{\circ}C$의 경우였으며 $45^{\circ}C,\;60^{\circ}C$의 경우에서는 이론보다 빠르게 진행되었으나 오차의 범위내에 있었다. 3. 추출속도의 온도의존성은 추출곡선의 기울기 (K)에 대하여 절대온도(T)의 11승에 비례하여 증가하였다. 4. 수분함량이 추출속도에 미치는 영향은 $32.42\%$에서 적을수록 추출속도는 빨랐으며. 추출곡선의 기울기(K)는 수분함량 $1\%$의 감소에 대략 $0.53{\times}10^{-6}cm^2/sec$씩 증가하였다.

  • PDF

EFFECTS OF GRID SPACER WITH MIXING VANE ON ENTRAINMENTS AND DEPOSITIONS IN TWO-PHASE ANNULAR FLOWS

  • KAWAHARA, AKIMARO;SADATOMI, MICHIO;IMAMURA, SHOGO;SHIMOHARAI, YUTA;HIRAKATA, YUDAI;ENDO, MASATO
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.389-397
    • /
    • 2015
  • The effects of mixing vanes (MVs) attached to a grid spacer on the characteristics of air-water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV), the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

Fatty Acid Composition and Stability of Extracted Mackerel Muscle Oil and Oil-Polyethylene Glycol Particles Formed by Gas Saturated Solution Process

  • Haque, A.S.M. Tanbirul;Asaduzzaman, A.K.M.;Chun, Byung-Soo
    • Fisheries and Aquatic Sciences
    • /
    • 제17권1호
    • /
    • pp.67-73
    • /
    • 2014
  • The oil in mackerel muscle was extracted using an environment friendly solvent, supercritical carbon dioxide (SC-$CO_2$) at a semibatch flow extraction process and an n-hexane. The SC-$CO_2$ was maintained at a temperature of $45^{\circ}C$ under pressures ranging from 15 to 25 MPa. The flow rate of $CO_2$ (27 g/min) was constant during the entire 2 h extraction period. The fatty acid composition of the oil was analyzed using gas chromatography (GC). Significant concentrations of eicosapentaenoic acid (EPA) acid and docosahexaenoic acid (DHA) acid were present in the SC-$CO_2$ extracted oil. The oil extracted using SC-$CO_2$ exhibited increased stability compared with n-haxane extracted oil. Particles of mackerel oil together with the biodegradable polymer, polyethylene glycol (PEG) were formed using a gas saturated solution process (PGSS) with SC-$CO_2$ in a thermostatted stirred vessel. Different temperatures ($45-55^{\circ}C$), pressures (15-25 MPa) and a nozzle size $400{\mu}m$ were used for PGSS with a 1 h reaction time. The stability of mackerel oil in the particles did not changed significantly.

동해 연근해에서 수중통신 채널의 지배응답 검출을 통한 시간 상관도의 산출 (Extraction of Time Coherence Using Detection of Dominant Components for Underwater Acoustic Communication Channels at East Sea)

  • 김현수;김재영;박건우;김성일;정재학
    • 한국음향학회지
    • /
    • 제32권1호
    • /
    • pp.22-31
    • /
    • 2013
  • 본 논문에서는 전송된 수중통신신호로부터 MMSE(Minimun Mean Squared Error) 기법으로 채널 응답을 추정하고, CFAR(Constant False Alarm Rate) 기법을 이용하여 응답성분의 전력을 기준으로 채널의 지배적인 응답을 자동적으로 구하는 방법을 제안한다. 그리고 표류상태의 송수신단을 이용한 해상실험 데이터로부터 얻은 지배적인 응답에서 응답세기 분포와 위상 변화 그리고 시간 상관도를 산출하여 통계적 특성을 분석한다. 제안된 방법을 이용하여 구해진 통계적 특성을 실제 측정 데이터에 적용했을 때 모든 데이터 구간에서의 채널을 추정하지 않더라도 모든 데이터 구간에서의 채널을 추정하는 경우보다 비트 오류율이 약 1.2배로 차이가 크지 않음을 보였다.

Comparison of Different Permeability Models for Production-induced Compaction in Sandstone Reservoirs

  • To, Thanh;Chang, Chandong
    • 지질공학
    • /
    • 제29권4호
    • /
    • pp.367-381
    • /
    • 2019
  • We investigate pore pressure conditions and reservoir compaction associated with oil and gas production using 3 different permeability models, which are all based on one-dimensional radial flow diffusion model, but differ in considering permeability evolution during production. Model 1 assumes the most simplistic constant and invariable permeability regardless of production; Model 2 considers permeability reduction associated with reservoir compaction only due to pore pressure drawdown during production; Model 3 also considers permeability reduction but due to the effects of both pore pressure drawdown and coupled pore pressure-stress process. We first derive a unified stress-permeability relation that can be used for various sandstones. We then apply this equation to calculate pore pressure and permeability changes in the reservoir due to fluid extraction using the three permeability models. All the three models yield pore pressure profiles in the form of pressure funnel with different amounts of drawdown. Model 1, assuming constant permeability, obviously predicts the least amount of drawdown with pore pressure condition highest among the three models investigated. Model 2 estimates the largest amount of drawdown and lowest pore pressure condition. Model 3 shows slightly higher pore pressure condition than Model 2 because stress-pore pressure coupling process reduces the effective stress increase due to pore pressure depletion. We compare field data of production rate with the results of the three models. While models 1 and 2 respectively overestimates and underestimates the production rate, Model 3 estimates the field data fairly well. Our result affirms that coupling process between stress and pore pressure occurs during production, and that it is important to incorporate the coupling process in the permeability modeling, especially for tight reservoir having low permeability.