• Title/Summary/Keyword: extracted teeth

Search Result 841, Processing Time 0.034 seconds

REMINERALIZATION EFFECT OF FUJI VII GLASS IONOMER CEMENT (Fuji VII 글래스 아이오노머 시멘트의 재광화 효과)

  • Kim, Young-Jin;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.653-660
    • /
    • 2006
  • Fuji VII is a glass-ionomer cement specially targeted for early protection in erupting first and second molars. Properties of Fuji VII such as very high level of fluoride release, low viscosity and no need to preliminarily etch the substrate would be useful to erupting molars with primary pit and fissure caries or hypoplastic area for preventive goal or remineralization. The purpose of this study were to evaluate remineralization of Fuji VII glass ionomer cement and to compare with one of other restorative materials such as conventional glass ionomer cement, resin-modified glass ionomer cement, compomer and composite resin. Forty-two extracted human molars were used for this study. All teeth were immersed in demineralizing solution for 48 hours after Class V cavity preparation was made on sound proximal surface. The teeth were randomly divided into six groups and restored with Fuji VII, Fuji II, Fuji II LC improved, F2000, $Filtek^{TM}$ Z250 and control group was unrestored. The middle area with $130{\pm}20{\mu}m$ thickness was separated from specimen using microtome and demineralized area was photographed under polarized microscope. Separated area was relocated to specimen and stored in artificial saliva, After four weeks, changes of demineralized area were observed and compared to them restorated immediately. The results from the this study can be summarized as follows ; 1. Fuji VII, Fuji II, Fuji II LC improved have more prominent remineralization effect than F2000, $Filtek^{TM}$ Z250, control group. 2. No significant differences in remineralization effect are seen between Fuji VII and Fuji II, Fuji II LC improved.

  • PDF

REMINERALIZATION EFFECT OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: IN VITRO STUDY USING QLF (QLF(Quantitative light-induced fluorescence)를 이용한 글라스 아이오노머 수복물의 인접면 우식 재광화 효과에 관한 연구)

  • Lee, Hyeok-Sang;Hyun, Hong-Keun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.244-249
    • /
    • 2011
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements(highly-filled glass ionomer cement, resin-modified glass ionomer cement, compomer) and a resin composite(control). Thirty-two extracted premolars were selected based upon the lack of any visible demineralization. The teeth were coated in a transparent acid resistant nail varnish leaving $3{\times}3$ mm square. The teeth were subjected to the demineralizing buffer for 3 days and quantitative light-induced fluorescence(QLF) images of the subjects were taken. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 with constant circulation. Further QLF images were subsequently taken at 30, 60, and 90 days. The changes of mineral loss(${\Delta}Q$) were evaluated by QLF and the change of ${\Delta}Q$(${\Delta}{\Delta}Q$) were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using ANOVA and the post-HOC Dunnett C multiple comparison test at p<0.05. While ${\Delta}Q$(changes of mineral loss) increased for all treatments, the increases for three glass ionomer groups were significantly higher than that for the resin group at first month period. As time went on, the amount of ${\Delta}{\Delta}Q$ decreased.

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.

EFFECTS OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACES ON BOND STRENGTH (산 표면처리후 상아질과 법랑질 표면의 습윤이 결합강도에 미치는 영향)

  • Lee, Kwang-Won;Park, Soo-Joung;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.328-341
    • /
    • 1995
  • I. Shear Bond Strength to Air-dried and Remoistened Dentin.. The effect of air-drying and remoistening of acid-conditioned dentin before priming with the primer of All-Bond 2(BISCO. INC., U. S. A.) on shear bond strength(SBS) was investigated. Ninty freshly extracted sound human molars were divided at random into 9 groups of 10 teeth each. SBSs were meaured for acid-conditioned and non-conditioned dentin to which the primer and bonding agent of All-Bond 2 and composite resin(Z-100, 3M Dental Products, U. S. A.) were applied. The following values(Mean${\pm}$ SD, MPa) were obtained for the groups conditioned with 10% phosphoric acid for 15 seconds: Group l(blot dried) $6.7{\pm}4.1$ ; Group 2(10 seconds dried) $16.1{\pm}5.3$ ; Group 3(20 seconds dried) $15.4{\pm}4.8$ ; Group 4(30 seconds dried) $15.2{\pm}6.3$ ; Group 5(10 seconds dried/remoistened) $26.4{\pm}2.6$ ; Group 6(20 seconds dired/remositened) $22.2{\pm}2.7$ ; Group 7(30 seconds dried/remoistened) $21.5{\pm}4.1$. For the non-conditioned groups the values were: Group 8 (blot dried) $13.3{\pm}2.6$ ; Group 9(10 seconds dried) $12.9{\pm}3.5$. The data were analyzed using ANOVA. In the acid-conditioned groups, mean values of SBS for the air-dried specimens(Grps. 2, 3 and 4) and the 20 and 30 seconds dried/remoistened specimens (Grps. 6 and 7) were significantly lower than that of blot dried specimens.(p<0.05) The value for 10 seconds dried/remoistened specimens (Grp. 5), however, was not statistically different compared to that of blot dried specimens.(p>0.05) In the non-conditined groups, there was no statistical difference between blot dried and 10 seconds dried specimens.(p>0.05) The results suggest that the acid-conditioned dentin surface is more vulnerable to dentin bonding when it is air-dried or even remoistened after long period of drying. II. Shear bond stengh to the moistened and primed enamel. The effect of moistening and priming of enamel compared to the air-drying of enamel on the shear bond strength of enamel bonding agent was investigated. The experiment was divided into 4 groups each containing 10 caries-free maxillary incisor teeth. Shear bond strength values were measured for the primed and non-primed enamel to which All-Bond 2 and Z-100 were applied. The following values(MPa) were obtained for the primed groups pretreated with 32 % phosphoric acid for 15 seconds. : Group 1 (10 seconds dried) $29.8{\pm}2.2$ ; Group 2(moistened) $26.8{\pm}5.4$. For the non-primed groups the values were: Group 3(10 seconds dried/primed) $27.6{\pm}5.0$ ; Group 4(mostened/primed) $28.2{\pm}3.5$. The data were subjected to statistical analysis using ANOVA. The results showed that mean shear bond strengths among the experimental groups were not statistically different. (p>0.05) Conclusively, It is suggested that the bonding ability to enamel is not decreased by the moistening and priming of the enamel.

  • PDF

Evaluation of time-dependent antimicrobial effect of sodium dichloroisocyanurate (NaDCC) on Enterococcus faecalis in the root canal (이염화이소시아뉼산나트륨 제재의 근관 내 사용 시 시간에 따른 E. faecalis에 대한 항균성 평가)

  • Kim, Hye-Jeong;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.121-129
    • /
    • 2007
  • The purpose of this study was to assess the antibacterial effect of sodium dichloroisocyanurate (NaDCC), sodium hypochlorite (NaOCl), and chlorhexidine (CHX) on Enterococcus faecalis and to evaluate and to compare the time-dependant antimicrobial effect of NaDCC with NaOCl and CHX in the root canal in vitro before and after instrumentation. Extracted Human single teeth were prepared by serial instrumentation technique. The samples were autoclaved and contaminated for 3 days with E. faecalis monocultures. The teeth were then divided into 4 groups Each group was irrigated and inserted with 2% NaOCl, 2% NaDCC, 2% CHX and steri)ized saline. After 6, 12, 24, 72h, and 1 week incubation, sterilized paper point was inserted into the root canal. Paper points containing root canal contents were then placed on the agar plate. And then each root cana) was prepared with #4 and #5 GG (Gates-Glidden) drill. The debris were collected in the sterilized microtube and the plates were incubated at $37^{\circ}C$ in an increased $CO_2$ atmosphere. After 24h incubation the growth of bacteria around the paper points were measured. NaOCl and NaDCC solution shows similar antimicrobial effect for E. faecalis at 6, 12, 24, 72h and 1 week. In centrol group, irrigated with sterilized saline, no antimicrobial effect was observed. The results are in agreement with other investigators, who have shown the bactericidal property and possibility of NaDCC as a root canal irrigation solution. Thus it seems that NaDCC solutions can be clinically applied into the root canal within 1 week after dilution.

Pulp Response of Mineral Trioxide Aggregate, Calcium Sulfate or Calcium Hydroxide (Mineral trioxide aggregate, calcium sulfate와 calcium hydroxide의 치수에 대한 반응)

  • Yun, Young-ran;Yang, In-Seok;Hwang, Yun-Chan;Hwang, In-Nam;Choi, Hong-Ran;Yoon, Suk-Ja;Kim, Sun-Hun;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • This study was performed to verify the possibility of MTA and calcium sulfate as a pulp capping agent through comparing the dental pulp response in dogs after capping with MTA, calcium sulfate, and calcium hydroxide. 24 teeth of 2 dogs, 8 month old, were used in this study. Under general anesthesia, cervical cavities were prepared and pulp was exposed with sterilized #2 round bur in a high speed handpiece. MTA calcium hydroxide, and calcium sulfate were applied on the exposed pulp. Then the coronal openin,fs were sealed with IRM and light-cured composite. Two months after treatment, the animals were sacrificed. The extracted teeth were fixed in 10% neutral-buffered formalin solution and were decalcified in formic acid-sodium citrate. They were prepared for histological examination in the usual manner. The sections were stained with haematoxylin and eosin. In MTA group, a hard tissue bridges formation and newly formed odontoblasts layer was observed. There was no sign of pulp inflammatory reaction in pulp tissue. In calcium hydroxide group, there was no odontoblast layer below the dentin bridge. In pulpal tissue, chronic inflammatory reaction with variable intensity and extension occurred in all samples. In calcium sulfate group, newly formed odontoblast layer was observed below the bridge. Mild chronic inflammation with a few neutrophil infiltrations was observed on pulp tissue. These results suggest that MTA is more biocompatible on pulp tissue than calcium hydroxide or calcium sulfate.

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구)

  • Maeng, Myoung-Ho;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.207-220
    • /
    • 2006
  • The newly developed equipments for the early detection of carious lesion are LFD (laser fluorescence device), Ultrasonic diagnostic system, CLSM(confocal laser scanning microscopy), QLF(quantitative light-induced fluorescence) and DIFOTI (digital imaging fiber-optic trans-illumination) system. In this study, DIFOTI system and LFD were used for the detection of early enamel caries. Twenty five primary teeth extracted from twenty one children at around the dentitional exchanging period were selected as samples. The results obtained from DIFOTI imaging and LFD measurement were compared with those of CLSM and comprehensive evaluations were made for the diagnostic capacity of each device. In vitro test, 40 sample teeth with their buccal & lingual surface formed by a window of $2{\times}3mm$ in diameter were immersed in artificial demineralizing solution for the period of 4, 8, 12 and 16 days. The results obtained from the experimental groups (DIFOTI, LFD) were compared to control group (CLSM) and we have reached to the following conclusions. 1. The sensitivity and specificity of DIFOTI system operated in oral environment was 88.2% and 76.9% respectively. 2. The sensitivity and specificity of LFD measured in oral environment was 76.5% and 69.2% respectively. 3, Regression analysis on the light transparent rate of DIFOTI showed its decrease according to the length of primary enamel decalcification performed in vitro(r=-0.96, p<0.05). 4. No statistically significant difference between LFT measurement and the length of in vitro decalcification was found in regression analysis (p>0.05). 5. The correlation coefficient of DIFOTI image transparent rate and the lesion depth of CLMS was -0.6988 (p<0.05), whereas no statistically significant difference was found for LFD measurement.

  • PDF

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF