• Title/Summary/Keyword: extra high voltage cable

Search Result 38, Processing Time 0.026 seconds

Investigation on The Effects of Processing Aids in Semiconductive Compounds for Extra High Voltage Cables (초고압 케이블용 반도전 재료에 미치는 가공 조제의 영향에 관한 연구)

  • Lee, Kyung-Won;Lee, Jung-Hee;Lee, Gun-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.112-115
    • /
    • 2002
  • The effects of processing aids(P.A.) in semicoductive compounds(S.C.) with highly loaded carbon black for extra high voltage cables were investigated. The processability of S.C. is improved as the contents of P.A. increased, however, the electrical, mechanical properties and smoothness of S.C. grew worse, especially for the S.C. which contains 5wt% of P.A., the volume resistivity after heat cycle which shows long term reliability increased about three times after 15cycles compared to the S.C. which contains no P.A. We inferred that it is caused by the action of P.A. as the insulating sites, thermal expansion of polymer matrix which leads the length between carbon blacks to shorten, and the decrease of degree of crosslinking. The change of ion contents which means cleanliness of S.C. is not occured regardless of the addition of P.A.

  • PDF

A study or Metallic sheath for Extra-high voltage XLPE cable (초고압 XLPE 케이블 금속 차폐층 고찰)

  • Choi, C.S.;Lee, K.J.;Chung, M.Y.;Kwon, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

The Analysis of Discharge Distribution due to the Inner Void of Extra High Voltage Cable

  • Kim Tag-Yong;Hong Jin-Woong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.155-160
    • /
    • 2005
  • This paper addresses the discharge characteristics of cross-linked polyethylene according to void by the Weibull function. It analyzes discharge number and amount of discharge using Weibull distribution to identify the inter-relationship between partial discharge and defect. We detected a 10 second discharge. The applied voltage increased by 1 [kV] at discharge inception voltage. As a result, in a no-void specimen, the shape parameter was consistent according to the increase of voltage, whereas, in a void specimen, it increased according to the increase of voltage. As the result, the shape parameter expressed a fixed value at no-void specimen. However, in void specimen, according to increasing voltage shape parameter rapidly increases.

A Evaluation Technique for Reliability of Extra-High Voltage Cable Accessories using High Frequency Partial Discharge Measurement (고주파 부분방전 측정에 의한 초고압 접속함 신뢰성 평가 기술)

  • Sin, Du-Seong;Lee, Chang-Yeong;Kim, Chung-Sik;Jeon, Seung-Ik;Kim, Dong-Uk;Park, Wan-Gi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.3
    • /
    • pp.186-195
    • /
    • 2000
  • In this paper, partial discharge (PD) measurement was performed to evaluate the quality of the cable joint and termination constructions. The resistive coupling technique for PD detection using resistivity of semiconducting layer of the cable in the accessories, such as joints and terminations. With high frequency PD (HEPD) measurement, an excellent sensitivity below 20pC could be achieved under unshielded condition. The localization of the defects in the accessories could be identified. During heating cycle, PDs were monitored and analyzed. At that time, the PDs were dependent on the temperature of the heating cycle and showed cyclic behaviors, which were attributed to local delamination of the interfaces, between epoxy unit and stress relief cone(SRC) and between SRC and cable, due to the difference of thermal expansion. As a conclusion, HFPD measurement technique was proven to be an effective diagnostic method for qualification of extra high voltage (EHV) cable accessories. With this technique, the optimal design of the components of the accessories could be verified not only in an early stage but also under operating condition. This technique would result in the improvement of the reliability of the EHV cable accessories.

  • PDF

A Study on the Electric Field Analysis of Extra-High Voltage Oil-Filled Cable Accessories (초고압 지중 OF 케이블 접속재의 전계해석에 관한 연구)

  • Lee, Jong-Bum;Kang, Dong-Sik;Kang, Do-Hyun;Lee, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.432-435
    • /
    • 1989
  • This paper presents an algorithm for electric field analysis which is essential to insulation design of extra-high voltage oil-filled cable accessories using finite element method. Governing equation is induced by electromagnetic equation. Variational method is adopted for FEN formulation. Automatic mesh generation which saves time and labor is introduced for the input data. The application results of proposed algorithms were used for insulation design to develop 345kV cable joint.

  • PDF

Determination of Proto Type for 345kV CV Cable Accessories (345kV CV 케이블 접속함의 Proto Type 선정)

  • Lee, S.K.;Kim, I.T.;Son, S.H.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

Development of Pre-Mold Joints for High Voltage Cable System (I) (초고압 프리몰드형 접속함 개발 (I))

  • Lee, S.K.;Ko, E.K.;Kim, Y.H.;Baik, S.Y.;Kim, K.S.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1031-1033
    • /
    • 1999
  • The performance of cable joints for extra high voltage XLPE cable system is rapidly advancing combined with the development of insulation materials. The current trend of joints is in the direction of requiring less jointing techniques and installation time. This paper describes the performance of currently used joints regarding to their practical aspects and analyses design and manufacturing techniques for Pre-Mold Joint and Pre-fabricated Joint Box. Especially, basic tests and their results to obtain the design Parameter of PMJ are introduced.

  • PDF

The Development of the compact accessories for 230kV XLPE cable (Compact 230kV 케이블용 접속함 개발)

  • Lee, Hyeong-Seok;Son, Si-Ho;Kim, Kwang-Soo;Lee, Kwang-Yeol;Chang, Ki-Wook;Bai, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1075-1077
    • /
    • 1999
  • XLPE cables are being used more widely all over the world as extra-high voltage transmission lines owing to the superior characteristics compared to OF cables. In view of the worldwide trend of utilizing high stress cables, we developed the accessories for 230kV XLPE cables which have smaller insulation thickness than that of present cables. The performance of the newly developed 230kV cable and its accessories has superior inital characteristics. As a result, the improved reliability of 230kV XLPE cable system has been obtained. This paper describes the major design concept and the test results of development procedure.

  • PDF

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

154KV개봉. 오류 지중송전선로 준공보고

  • 김성곤;정수근
    • 전기의세계
    • /
    • v.29 no.11
    • /
    • pp.693-698
    • /
    • 1980
  • We T.E.C. have commenced to develop the O.F. cable in April, 1977. Now we have finished the Type-Test and produced in full-operation of 154KV 1x600mm$^{2}$ and 154KV 1x1200mm$^{2}$ O.F. cables. Especially we have completed pulling and splicing of the 24.82kms O.F. cable in KaeBong-OuRyu Route, and now it is operating well. This has important meaning that Extra High Voltage Under Ground Transmission Line has constructed by domastic engineers for the first time in Korea. Thank to arrange and publish it, and hope it can be helpful to the related.

  • PDF