• 제목/요약/키워드: extra dose

검색결과 48건 처리시간 0.018초

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su;Choi, Chansoo;Kim, Chan Hyeong;Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Kim, Seonghoon;Choi, Sang Hyoun;Lee, Soon Sung;Kim, Jina;Hwang, JinHo;Kang, Youngnam
    • Journal of Radiation Protection and Research
    • /
    • 제44권3호
    • /
    • pp.103-109
    • /
    • 2019
  • Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.

치과방사선 검사에서 두부(brain)의 흡수선량 평가 (Evaluation the absorbed dose in brain of dental radiography)

  • 전운선;한동균
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.343-349
    • /
    • 2011
  • 치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.

Comparison of Two pMDIs in Adult Asthmatics: A Randomized Double-Blind Double-Dummy Clinical Trial

  • Nam, Tae-Hyun;Kang, Sung-Yoon;Lee, Sang Min;Kim, Tae-Bum;Lee, Sang Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • 제85권1호
    • /
    • pp.25-36
    • /
    • 2022
  • Background: Only a few studies directly compared the therapeutic efficacy and safety of two pressurized metered-dose inhalers (pMDIs) in asthma. We analyzed the asthma treatment outcomes, safety, and patient preferences using formoterol/beclomethasone (FORM/BDP), a pMDI with extra-fine particles, compared with formoterol/budesonide (FORM/BUD), another pMDI with non-extra-fine particles. Methods: In this randomized, double-blind, double-dummy parallel group study, 40 adult asthmatics were randomized to FORM/BDP group (n=18; active FORM/BDP and placebo FORM/BUD) or FORM/BUD group (n=22; active FORM/BUD and placebo FORM/BDP). During the two visits (baseline and end of 8-week treatment), subjects were asked to answer questionnaires including asthma control test (ACT), asthma control questionnaires (ACQ), and Quality of Life Questionnaire for Adult Korean Asthmatics (QLQAKA). Lung function, compliance with inhaler, and inhaler-handling skills were also assessed. Results: Ten subjects in the FORM/BDP group and 14 in the FORM/BUD group completed follow-up visits. ACT, ACQ, QLQAKA (a primary outcome), and adverse events did not differ between two groups. We found that the increase in forced expiratory volume in 1 second/forced vital capacity and forced expiratory flow at 25% to 75% of the pulmonary volume in the FORM/BDP group was higher than in the FORM/BUD group. Regarding preference, subjects responded that the flume velocity of FORM/BDP was higher, but more adequate than that of FORM/BUD. They also answered that FORM/BDP reached the trachea and bronchus and irritated them significantly more than FORM/BUD. Conclusion: The use of pMDI with extra-fine particles may relieve small airway obstruction more than the one with non-extra-fine particles despite no significant differences in overall treatment outcomes. Some asthmatics have a misconception about the adequacy of high flume velocity of pMDIs.

토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교 (Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy)

  • 이병구;강수만
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.145-149
    • /
    • 2013
  • 의료용 선형가속기 (linear accelerator)와 나선형 컴퓨터 단층 촬영 장치 (helical computed tomography scanner)의 결합 장치인 토모테라피는 세기 변조 방사선 치료 (intensity modulated radiation therapy(IMRT))의 큰 혁신을 이끌었다. 토모테라피 치료 과정에서, Megavoltage computed tomography (MVCT) 영상획득은 치료 환자의 정확한 자세 정렬을 위해 치료 전 또는 후에 이용된다. 그러나 이는 환자의 총 선량을 증가시키는 결과를 만들며, 본 연구는 이처럼 MVCT 영상 획득 시 증가되는 선량을 Cylindrical "Cheese" Phantom을 이용하여 측정, 비교하였다. 각각의 pitch 별로 (1, 2, 3 mm) 동일한 개수의 slice (10 slice), 그리고 동일한 length (약 9 cm)를 scanning하여, 이때의 선량 (MVCT Scanning Dose)을 A1SL ion chamber를 이용하여 측정하였다. 측정 결과 동일한 Slice 개수 (각각의 pitch 당 10개)일 때, MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.24 cGy, 1.02 cGy, 0.81 cGy가 측정되었다. 동일한 length에서 MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.47 cGy, 1.28 cGy, 0.88 cGy가 측정되었다. 이는 할당된 pitch와 scanning length가 MVCT scanning dose에 큰 영향을 미치는 가장 중요한 매개 변수임을 말하며, pitch는 MVCT scanning dose와 역비례 관계를 나타냈다. 때문에 적절한 pitch와 scanning length의 선택으로 치료 선량 외의 추가 선량을 최소로 줄여야 하겠다.

결장뉴 전기활동도에 대한 칼슘 길항제의 영향 (Effects of $Ca^{2+}-antagonists$ on the electrical activity of guinea-pig taenia coli)

  • 김기환;김우겸
    • The Korean Journal of Physiology
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 1985
  • The influences of $Ca^{2+}-antagonists$, verapamil and $Mn^{2+}$, upon the spontaneous electrical activity and contractions were studied in guinea-pig taenia coli. Spontaneous contractions were recorded with force transducer, and spike action potentials were measured extracellularly by use of suction electrode. All experiments were performed in tris-buffered Tyrode solution Which was aerated With 100% $O_2$ and kept at $35^{\circ}C$. The results obtained were as follows : 1) Verapamil suppressed the frequency and amplitude of spontaneous contractions dose dependently, and blocked completely mechanical responses at the concentration of 1 mg/1. 2) The frequency of bursts of spike discharge(bursts frequency) and the number of spikes in a burst(spikes frequency) were reduced in a dose·dependent manner within the concentration range of $10^{-5}$ to $10^{-3}g/l$, and bursts frequency was affected more readily at a low concentration of $10^{-5}g/l$ verapamil. 3) The verapamil_induced suppression of spontaneous contractions in the Tyrode solution containing 1 mM $Ca^{2+}$ was completely antagonized by the addition of extra $Ca^{2+}$ to the Tyrode solution $(2\;m\;MCa^{2+})$. 4) $Mn^{2+}$ suppressed the amplitude of spontaneous contractions, whereas $Mn^{2+}$ accelerated the frequency dose-dependently within the range of low concentrations$(10^{-7}\;to\;10^{-4}\;M\;Mn^{2+})$. 5) The bursts frequency determining frequency of spontaneous contractions was increased in a dose-dependent manner, whereas the spikes frequency known to determine the contractions amplitude was reduced within the range of low concentrations. At a high concentration of 1 mM $Mn^{2+}$, however, all spontaneous contractile responses were blocked simultaneously with the disapperance of electrical activity. 6) The frequency and amplitude of spontaneous contractions altered by $Mn^{2+}$ in 1mM $Ca^{2+}$ Tyrode were increased by extra $Ca^{2+}(2mM)$.

  • PDF

추체외로 증상에 따른 항정신병 약물 복용량과 음성 특성의 상관관계 분석 (Correlation analysis of antipsychotic dose and speech characteristics according to extrapyramidal symptoms)

  • 이수빈;김서영;김혜윤;김의태;유경상;이호영;이교구
    • 한국음향학회지
    • /
    • 제41권3호
    • /
    • pp.367-374
    • /
    • 2022
  • 본 논문은 항정신병 약물의 복용량에 따른 음성 특징의 상관관계 분석을 수행하였다. 항정신병 약물의 대표적 부작용 중 하나인 추체외로 증상(ExtraPyramidal Symptoms, EPS) 발생에 따른 음성 특징의 패턴을 알아보기 위하여, 문장 개발을 통해 한국어 기반 추체외로 증상 음성 코퍼스를 구축하였다. 수집된 자료는 추체외로 증상 군과 비 추체외로 증상 군으로 나누어 음성 특징 패턴을 조사하였으며, 특히 추체외로 증상 군의 높은 음성 특징 상관관계를 보였다. 또한, 발화 문장의 종류가 음성 특징 패턴에 영향을 미친다는 것을 확인할 수 있었으며, 이를 통해 음성 특징을 기반한 추체외로 증상의 조기 발견 가능성을 기대해볼 수 있었다.

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • 한국의학물리학회지:의학물리
    • /
    • 제34권4호
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

수술중 전자선치료에 있어서 선량분포에 관한 연구 (A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.1-12
    • /
    • 1992
  • 전자선을 이용한 수술중 방사선치료를 위해서는 수술중에 드러내 놓은 종양에 고선량의 방사선을 조사하되 주변 정상 조직을 보존하기 위하여 cone 장치를 개발할 필요가 있으며, 임상에 필요한 자료를 얻는 것 뿐만아니라 콜리메이터에 의한 적정 X-선 창 크기도 정할 필요가 있다. holder와 cone으로 이루어진 알루미늄제 결합형 cone장치를 개발하였다. 광자선의 SSD 100cm에서 조사면 크기가 직경 4~9cm이면서 lcm씩 차이가 있는 28cm 길이의 원통형 cone을 만들였으며, holder는 cone의 직경이 7cm이상인 것과 미만인을 것을 접속시키기 위해 따로 두 개를 만들었다. holder의 측면에는 조사부위를 관찰하기 위한 거울과 조명등을 삽입할 수 있는 개구부를 두었다. cone에 의한 조사면 크기와 콜리메이터에 의한 X선 창의 크기의 여러 가지 결합에 대하여 수중의 전자선의 깊이선량분포독선 및 측방선량분포곡선, 선량분포를 1차원 물팬톰 장치로 조종하는 p-형 실리콘 검출기로 측정하였다. 출력계수도 p-형 실리콘 검출기로 수중에서 측정하였다. 전자선의 에너지와 cone의 크기의 결합이 일정할지라도 콜리메이터에 의한 X-선 창의 크기는 표면선량 및 최대신량점의 깊이, 80% 선량점의 깊이, 측방선량분포, 출력계수에 영향을 미쳤다. 그중, 출력계수의 변화가 가장 현저하였다. 예로서 9 MeV 전자선의 출력계수는 0.637과 1.549의 범위에 있었다. 콜리메이터에 의한 X-선 창의 크기는 수술중 전자선치료용 cone 장치의 벽으로 향하는 산란 전자의 양에 영향을 미치고, cone장치에서 다시 산란된 전자는 출력계수 뿐만 아니라 선량분포도 바꿀 것으로 생각된다. 따라서 수술중 전자선치료용 cone장치에 대한 선량분포 측정은 임상에서 선량의 불확정도를 최소화하기 위해 필수적이다.능적으로 평가되어야 하므로 앞으로 이에 대한 연구가 요구된다.수 있었다. 즉, $a^{*}$ / $b^{*}$ 의 비값이 1이상 흑은 1에 가까울 때는 미숙기, 0.8 부근 일때는 적숙기, 0.8보다 작아 질수록 적숙기에서 과숙기로 점차 옮아감을 알 수 있었다.지해줄 수 있는 문헌들이 충분히 고찰되지 못하였고, 이론적배경 또한 횡문화 이론과의 관련성이 적었다. 또한 횡 문화 연구에 기초가 되는 연구대상자의 사회 인구학적 특성과 역사적 배경은 잘 나타났으나, 이론적 연구와 경험적 연구 간에 괴리가 있었다. 3. 표본추출방법은 문화에 기반을 둔 대상자를 선정한다는 점에서 한계성 이 있었다. 4. 방법론적 이유로는 대상자와의 면담시간이 구체적으로 기술되지 않았으며, 고유한 언어를 통역하는 과정에서 의미론적 문제에 대한 고려가 부족하였다. 면접과 기록과정에서 보면 자료의 기록과정과 분류 및 분석과정이 명시되어 있지 않았다. 참여관찰과 면접방법을 사용시 이에 대한 자세한 기술이 되어 있지 않았다. 5. 연구결과의 적용 및 이에 대한 논의는 상당히 제한되어 있었는데, 수편의 연구만이 방법론 문제점과 앞으로의 연구분야에 대한 전망을 제시하였으며, 특이한 것은 어 떤 연구자도 이른 개발을 위한 적용 및 임상실무적 차원에서 간호에 대한 제언을 하지 않았다.유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard 알고리즘을 사용하였다. 서울 구로구 시흥동 산사태 발생 지역의 산사면에 대하여 개발된 모델을 적용하여 예제 해석을 수행함으로써, 지하수 흐름 모델이 산사태 발생 예측을 위하여 이용할 수 있음을 입증하였다. 또한, 매개변수분석 연구를 통하여, 변수 a값은 작은 변화에 대하여 목적함수값에 큰 변화를

  • PDF

Postoperative radiotherapy dose correlates with locoregional control in patients with extra-hepatic bile duct cancer

  • Im, Jung Ho;Seong, Jinsil;Lee, Jeongshim;Kim, Yong Bae;Lee, Ik Jae;Park, Jun Sung;Yoon, Dong Sup;Kim, Kyung Sik;Lee, Woo Jung
    • Radiation Oncology Journal
    • /
    • 제32권1호
    • /
    • pp.7-13
    • /
    • 2014
  • Purpose: To evaluate the results of postoperative radiotherapy in patients with extra-hepatic bile duct cancer (EHBDC) and identify the prognostic factors for local control and survival. Materials and Methods: Between January 2001 and December 2010, we retrospectively reviewed the cases of 70 patients with EHBDC who had undergone curative resection and received postoperative radiotherapy. The median radiation dose was 50.4 Gy (range, 41.4 to 54 Gy). The resection margin status was R0 in 30 patients (42.9%), R1 in 25 patients (35.7%), and R2 in 15 patients (21.4%). Results: The 5-year rates of overall survival (OS), event-free survival (EFS), and locoregional control (LRC) for all patients were 42.9%, 38.3%, and 61.2%, respectively. The major pattern of failure was distant relapses (33 patients, 47.1%). A multivariate analysis showed that the postradiotherapy CA19-9 level, radiation dose (${\geq}50$ Gy), R2 resection margins, perineural invasion, and T stage were the significant prognostic factors for OS, EFS, and LRC. OS was not significantly different between the patients receiving R0 and R1 resections, but was significantly lower among those receiving R2 resection (54.6%, 56.1%, and 7.1% for R0, R1, and R2 resections, respectively). Conclusion: In patients with EHBDC who had undergone curative resection, a postoperative radiotherapy dose less than 50 Gy was suboptimal for OS and LRC. Higher radiation doses may be needed to obtain better LRC. Further investigation of novel therapy or palliative treatment should be considered for patients receiving R2 resection.

Effect of Copper on Marine Microalga Tetraselmis suecica and its Influence on Intra- and Extracellular Iron and Zinc Content

  • Kumar, K. Suresh;Shin, Kyung-Hoon
    • 생태와환경
    • /
    • 제50권1호
    • /
    • pp.16-28
    • /
    • 2017
  • In an aquatic environment, toxicity of metals to organisms depends on external factors (type of metal, exposure concentration and duration, environmental parameters, and water quality) and intracellular processes(metal-binding sites and detoxification). Toxicity of copper(Cu) on the marine microalga Tetraselmis suecica was investigated in this study. Dose-dependent (Cu concentration dependent) inhibition of growth and cell division, as well as, variation of intra- and extra-cellular Cu, Fe and Zn content was observed. T. suecica was sensitive to Cu; the 96 h $EC_{50}$ (concentration to inhibit growth-rate by 50%) of growth rate (${\mu}$) ($21.73{\mu}M\;L^{-1}$), cell division $day^{-1}$ ($18.39{\mu}M\;L^{-1}$), and cells $mL^{-1}$ ($13.25{\mu}M\;L^{-1}$) demonstrate the toxicity of Cu on this microalga. High intra-($19.86Pg\;cell^{-1}$) and extra-cellular($54.73Pg\;cell^{-1}$) Cu concentrations were recorded, on exposure to 24.3 and $72.9{\mu}M\;L^{-1}$ of Cu.