References
- Feygelman V, Nelms B. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction. J. Phys. Conf. Ser. 2013;444:012012. https://doi.org/10.1088/1742-6596/444/1/012012
- Ezzell GA, et al. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med. Phys. 2009;36(11):5359-5373. https://doi.org/10.1118/1.3238104
- van Elmpt W, Nijsten S, Mijnheer B, Dekker A, Lambin P. The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations. Radiother. Oncol. 2008;86(1): 86-92.
- Renner WD, Sarfaraz M, Earl MA, Yu CX. A dose delivery verification method for conventional and intensity‐modulated radiation therapy using measured field fluence distributions. Med. Phys. 2003;30(11):2996-3005. https://doi.org/10.1118/1.1610771
- van Elmpt W, Nijsten SM, Schiffeleers RF, Dekker AL, Mijnheer BJ, Lambin P, Minken AW. A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images. Med. Phys. 2006;33(7):2426-2434. https://doi.org/10.1118/1.2207315
- Keall PJ, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med. Phys. 2006; 33(10):3874-3900. https://doi.org/10.1118/1.2349696
- Schreibmann E, Chen GT, Xing L. Image interpolation in 4D CT using a BSpline deformable registration model. Int. J. Radiat. Oncol. Biol. Phys. 2006;64(5):1537-1350. https://doi.org/10.1016/j.ijrobp.2005.11.018
- McClelland JR, Blackall JM, Tarte S, Chandler AC, Hughes S, Ahmad S, Landau DB, Hawkes DJ. A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. Med. Phys. 2006;33(9):3348-3358. https://doi.org/10.1118/1.2222079
- Yang D, Lu W, Low DA, Deasy JO, Hope AJ, Naqa IE. 4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling. Med. Phys. 2008;35(10):4577-4590. https://doi.org/10.1118/1.2977828
- Dowdell S, Grassberger C, Sharp GC, Paganetti H. Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters. Phys. Med. Biol. 2013;58(12):4137-4156. https://doi.org/10.1088/0031-9155/58/12/4137
- Paganetti H, Jiang H, Adams JA, Chen GT, Rietzel E. Monte Carlo simulations with time-dependent geometries to investigate effects of organ motion with high temporal resolution. Int. J. Radiat. Oncol. Biol. Phys. 2004;60(3):942-950. https://doi.org/10.1016/j.ijrobp.2004.06.024
- Chui H, Rangarajan A. A new point matching algorithm for nonrigid registration. Comput. Vis. Image. Und. 2003;89(2):114-141. https://doi.org/10.1016/S1077-3142(03)00009-2
- Hualiang Z, Jeffrey VS. Monte Carlo dose mapping on deforming anatomy. Phys. Med. Biol. 2009;54(19):5815-5830. https://doi.org/10.1088/0031-9155/54/19/010
- Han MC, Seo JM, Lee SH, Kim CH, Yeom YS, Nguyen TT, Choi C, Kim S, Jeong JH, Sohn JW. Continuously deforming 4D voxel phantom for realistic representation of respiratory motion in Monte Carlo dose calculation. IEEE. T. Nucl. Sci. 2016;63(6): 2918-2924. https://doi.org/10.1109/TNS.2016.2601080
- Foster KM, Stevens CW, Kitamura K, Chang JY, Cox JD, Guerrero TM, Jeter M, Liao Z, Starkschall G, Komaki R. Changes of tumor motion patterns during a course of radiation therapy for lung cancer, Int. J. Radiat. Oncol. Biol. Phys. 2003;57(2):S234. https://doi.org/10.1016/S0360-3016(03)01058-7
- McClelland JR, Hawkes DJ, Schaeffter T, King AP. Respiratory motion models: a review. Med. Image. Anal. 2013;17(1):19-42. https://doi.org/10.1016/j.media.2012.09.005
- Gierga DP, Brewer J, Sharp GC, Betke M, Willett CG, Chen GT. The correlation between internal and external markers for abdominal tumors: implications for respiratory gating. Int. J. Radiat. Oncol. Biol. Phys. 2005;62(4):1257. https://doi.org/10.1016/j.ijrobp.2005.06.001
- Yang D, Brame S, El Naqa I, Aditya A, Wu Y, Goddu SM, Mutic S, Deasy JO, Low DA. Technical Note: DIRART - A software suite for deformable image registration and adaptive radiotherapy research. Med. Phys. 2011;38(1):67-77. https://doi.org/10.1118/1.3521468
- Bruhn A, Weickert J, Schnorr C. Lucas/Kanade meets Horn/Schunck: combining local and global optic flow methods. International Journal of Computer Vision. 2005;61(3):211-231. https://doi.org/10.1023/B:VISI.0000045324.43199.43
- Kim J, Lee Y, Shin H, Ji S, Park S, Kim J, Jang H, Kang Y. Development of deformable moving lung phantom to simulate respiratory motion in radiotherapy. Med. Dosim. 2016;41(2):113-117. https://doi.org/10.1016/j.meddos.2015.10.004
- Rami-Porta R, Crowley JJ, Goldstraw P. Review the revised TNM staging system for lung cancer. Ann. Thorac. Cardiovasc. Surg. 2009;15(1):4-9.