DOI QR코드

DOI QR Code

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su (Department of Nuclear Engineering, Hanyang University) ;
  • Choi, Chansoo (Department of Nuclear Engineering, Hanyang University) ;
  • Kim, Chan Hyeong (Department of Nuclear Engineering, Hanyang University) ;
  • Han, Min Cheol (Department of Radiation Oncology, Yonsei University College of Medicine) ;
  • Yeom, Yeon Soo (Division of Cancer Epidemiology & Genetics, National Cancer Institute) ;
  • Nguyen, Thang Tat (School of Nuclear Engineering and Environmental Physics, Hanoi University of Science and Technology) ;
  • Kim, Seonghoon (Department of Radiation Oncology, College of Medicine, Hanyang University) ;
  • Choi, Sang Hyoun (Korea Institute of Radiological and Medical Sciences) ;
  • Lee, Soon Sung (Korea Institute of Radiological and Medical Sciences) ;
  • Kim, Jina (The Catholic University of Korea) ;
  • Hwang, JinHo (The Catholic University of Korea) ;
  • Kang, Youngnam (The Catholic University of Korea)
  • Received : 2019.04.10
  • Accepted : 2019.08.08
  • Published : 2019.09.30

Abstract

Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.

Keywords

References

  1. Feygelman V, Nelms B. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction. J. Phys. Conf. Ser. 2013;444:012012. https://doi.org/10.1088/1742-6596/444/1/012012
  2. Ezzell GA, et al. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med. Phys. 2009;36(11):5359-5373. https://doi.org/10.1118/1.3238104
  3. van Elmpt W, Nijsten S, Mijnheer B, Dekker A, Lambin P. The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations. Radiother. Oncol. 2008;86(1): 86-92.
  4. Renner WD, Sarfaraz M, Earl MA, Yu CX. A dose delivery verification method for conventional and intensity‐modulated radiation therapy using measured field fluence distributions. Med. Phys. 2003;30(11):2996-3005. https://doi.org/10.1118/1.1610771
  5. van Elmpt W, Nijsten SM, Schiffeleers RF, Dekker AL, Mijnheer BJ, Lambin P, Minken AW. A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images. Med. Phys. 2006;33(7):2426-2434. https://doi.org/10.1118/1.2207315
  6. Keall PJ, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med. Phys. 2006; 33(10):3874-3900. https://doi.org/10.1118/1.2349696
  7. Schreibmann E, Chen GT, Xing L. Image interpolation in 4D CT using a BSpline deformable registration model. Int. J. Radiat. Oncol. Biol. Phys. 2006;64(5):1537-1350. https://doi.org/10.1016/j.ijrobp.2005.11.018
  8. McClelland JR, Blackall JM, Tarte S, Chandler AC, Hughes S, Ahmad S, Landau DB, Hawkes DJ. A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. Med. Phys. 2006;33(9):3348-3358. https://doi.org/10.1118/1.2222079
  9. Yang D, Lu W, Low DA, Deasy JO, Hope AJ, Naqa IE. 4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling. Med. Phys. 2008;35(10):4577-4590. https://doi.org/10.1118/1.2977828
  10. Dowdell S, Grassberger C, Sharp GC, Paganetti H. Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters. Phys. Med. Biol. 2013;58(12):4137-4156. https://doi.org/10.1088/0031-9155/58/12/4137
  11. Paganetti H, Jiang H, Adams JA, Chen GT, Rietzel E. Monte Carlo simulations with time-dependent geometries to investigate effects of organ motion with high temporal resolution. Int. J. Radiat. Oncol. Biol. Phys. 2004;60(3):942-950. https://doi.org/10.1016/j.ijrobp.2004.06.024
  12. Chui H, Rangarajan A. A new point matching algorithm for nonrigid registration. Comput. Vis. Image. Und. 2003;89(2):114-141. https://doi.org/10.1016/S1077-3142(03)00009-2
  13. Hualiang Z, Jeffrey VS. Monte Carlo dose mapping on deforming anatomy. Phys. Med. Biol. 2009;54(19):5815-5830. https://doi.org/10.1088/0031-9155/54/19/010
  14. Han MC, Seo JM, Lee SH, Kim CH, Yeom YS, Nguyen TT, Choi C, Kim S, Jeong JH, Sohn JW. Continuously deforming 4D voxel phantom for realistic representation of respiratory motion in Monte Carlo dose calculation. IEEE. T. Nucl. Sci. 2016;63(6): 2918-2924. https://doi.org/10.1109/TNS.2016.2601080
  15. Foster KM, Stevens CW, Kitamura K, Chang JY, Cox JD, Guerrero TM, Jeter M, Liao Z, Starkschall G, Komaki R. Changes of tumor motion patterns during a course of radiation therapy for lung cancer, Int. J. Radiat. Oncol. Biol. Phys. 2003;57(2):S234. https://doi.org/10.1016/S0360-3016(03)01058-7
  16. McClelland JR, Hawkes DJ, Schaeffter T, King AP. Respiratory motion models: a review. Med. Image. Anal. 2013;17(1):19-42. https://doi.org/10.1016/j.media.2012.09.005
  17. Gierga DP, Brewer J, Sharp GC, Betke M, Willett CG, Chen GT. The correlation between internal and external markers for abdominal tumors: implications for respiratory gating. Int. J. Radiat. Oncol. Biol. Phys. 2005;62(4):1257. https://doi.org/10.1016/j.ijrobp.2005.06.001
  18. Yang D, Brame S, El Naqa I, Aditya A, Wu Y, Goddu SM, Mutic S, Deasy JO, Low DA. Technical Note: DIRART - A software suite for deformable image registration and adaptive radiotherapy research. Med. Phys. 2011;38(1):67-77. https://doi.org/10.1118/1.3521468
  19. Bruhn A, Weickert J, Schnorr C. Lucas/Kanade meets Horn/Schunck: combining local and global optic flow methods. International Journal of Computer Vision. 2005;61(3):211-231. https://doi.org/10.1023/B:VISI.0000045324.43199.43
  20. Kim J, Lee Y, Shin H, Ji S, Park S, Kim J, Jang H, Kang Y. Development of deformable moving lung phantom to simulate respiratory motion in radiotherapy. Med. Dosim. 2016;41(2):113-117. https://doi.org/10.1016/j.meddos.2015.10.004
  21. Rami-Porta R, Crowley JJ, Goldstraw P. Review the revised TNM staging system for lung cancer. Ann. Thorac. Cardiovasc. Surg. 2009;15(1):4-9.