• 제목/요약/키워드: external tube

검색결과 284건 처리시간 0.026초

A Study on the Fine Structure of the Marine Diatoms of Korean Coastal Waters - Genus Thalassiosira 3

  • Lee, Jin-Hwan;Park, Joon-Sang
    • ALGAE
    • /
    • 제23권3호
    • /
    • pp.187-199
    • /
    • 2008
  • A study on the fine structure of the marine diatom Thalassiosira has been carried out during the periods from January 2007 to March 2008 in Korean coastal waters. As the third series of the Thalassiosira species, a fine structure, description, distribution and taxonomic remarks of the six Thalassiosira species were observed by means of light microscope and scanning electron microscope. The critical features of Thalassiosira species were a shape of external tubes of marginal strutted processes and labiate process. Six species showed each different shape of external tubes, marginal strutted processes and labiate process. The shape of external tube was divided into five types: T shape of Thalassiosira curviseriata, small-rounded shape of T. lundiana, double-layer form and flame shape of T. nordenskioeldii, tulip shape of T. punctigera and tooth-shape of T. tenera. This external character may be able to key character for positive identification of the Thalassiosira species. Of these Thalassiosira lundiana, T. minuscula and T. tenera were new records for Korean coastal waters.

펀치형상이 팽창튜브의 파단불안전성에 미치는 영향 (Effect of Punch Shapes on Failure Instability of Expansion Tube)

  • 최원목;권태수;정현승;김진성
    • 한국자동차공학회논문집
    • /
    • 제19권2호
    • /
    • pp.125-132
    • /
    • 2011
  • The rupture of an expansion tube is mainly affected by the expansion ratio and the external shape of the punch used to expand the tube. In order to prevent the tube from rupture, the effect of the external shape of the punch should be considered in the design. The aim of this paper is to confirm the effect of key design parameters of the punch on rupture of the tube using a finite element analysis with a ductile damage model. The results of the analysis indicated that the expansion ratio of the tube was mainly affected by variation of the radius of the punch. However, the rupture was more affected by variation of the punch angle than the radius of the punch. The existence of a specific punch angle at which rupture did not occur, even if the radius of the punch was increased, was found from the results.

경항문 내시경 수술 도구에서의 최적 활동 반경 개선을 위한 컴퓨터 시뮬레이션 연구 (Computer Simulation of the Transanal Endoscopic Microsurgery for the Improvement of Optimal Operation Range)

  • 김형태;김광기;남경원;김현호;손대경
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.482-488
    • /
    • 2009
  • Conventional devices for transanal endoscopic microsurgery that are currently used clinically for intestine or rectal cancer patients have 40 mm external diameter of rectoscope tube - induces anal damage and long-term postoperative pain for small-sized patients. In this paper, we designed rectum and rectoscope models and calculated the changing trends of operation area of the surgical tools in accordance with the step-by-step variation of design parameters of the rectoscope tube - external diameter, axial length, and distal angle. Using the results of computer simulation, we suggested an optimal set of design parameters that minimizes external diameter of the rectoscope tube and at the same time, maintains similar operation area of the surgical tools compared with commercialized devices (${\geq}\;4274.7mm^2$). The results of the simulation showed that the optimal design parameters were 35 mm external diameter, 100 mm axial length, and $45^{\circ}$ distal angle of the rectoscope tube. This result can be applied to the development of endoscopic microsurgery device that can minimize side effects to the intestine or rectal cancer patients.

Cyclic test of buckling restrained braces composed of square steel rods and steel tube

  • Park, Junhee;Lee, Junho;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.423-436
    • /
    • 2012
  • In this study total of six buckling-restrained braces (BRBs) were manufactured using a square steel rod as a load-resisting core member and a hollow steel tube as restrainer to prevent global buckling of the core. The gap between the core and the tube was filled with steel rods as filler material. The performances of the proposed BRB from uniaxial and subassemblage tests were compared with those of the specimens filled with mortar. The test results showed that the performance of the BRB with discontinuous steel rods as filler material was not satisfactory, whereas the BRBs with continuous steel rods as filler material showed good performance when the external tubes were strong enough against buckling. It was observed that the buckling strength of the external tube of the BRBs filled with steel rods needs to be at least twice as high as that of the BRBs filled with mortar to ensure high cumulative plastic deformation of the BRB.

내외부 이중튜브구조를 갖는 핵연료봉의 봉단마개 용접시험 평가 (Evaluation of Endcap Welding Test for a Nuclear Fuel Rod having External and Internal Tube Structure)

  • 김수성;김종헌;김형규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1377-1380
    • /
    • 2008
  • An irradiation test of a nuclear fuel rod having external and internal tube structure was planned for a performance. To establish fabrication process satisfying the requirements of irradiation test, micro-TIG welding system for fuel rods was developed, and preliminary welding experiments for optimizing process conditions of fuel rod was performed. Fuel rods with 15.9mm diameter and 0.57mm wall thickness of cladding tubes and end caps have been used and optimum conditions of endcap welding have been selected. In this experiment, the qualification test was performed by tensile tests, helium leak inspections, and metallography examinations to qualify the endcap welding procedure. The soundness of the welds quality of a dual cooled fuel rods has been confirmed by mechanical tests and microstructural examinations.

  • PDF

증기발생기 나선형 전열관의 프레팅 마모 특성 (Fretting-wear Characteristics of Steam Generator Helical Tubes)

  • Jong Chull Jo;Woong Sik Kim;Hho Jung Kim;Tae Hyung Kim;Myung Jo Jhung
    • 한국소음진동공학회논문집
    • /
    • 제14권4호
    • /
    • pp.327-335
    • /
    • 2004
  • 본 연구에서는 가동중인 원자력발전소의 이물질에 의한 프레팅 마모 특성을 평가하였다. 다양한 조건의 나선형 튜브 고유진동수 및 모드 형상을 구하기 위하여 모드 해석을 수행하였다. 이물질에 의한 나선형 튜브의 마모율을 Archard 공식을 이용하여 계산하였고 이로부터 튜브의 잔여 수명을 예측하였으며 튜브의 진동 특성이 잔여 수명에 미치는 영향을 고찰하였다. 또한 튜브에 가해지는 외압이 진동 및 프레팅 마모 특성에 미치는 영향을 평가하였다.

나선형코일 튜브 비등2상 유동 수치해석 (Numerical Simulation of Boiling 2-Phase Flow in a Helically-Coiled Tube)

  • 조종철;김웅식;김효정;이용갑
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.49-55
    • /
    • 2004
  • This paper addresses a numerical simulation of the flow and heat transfer in a simplified model of helically coiled tube steam generator using a general purpose computational fluid dynamic analysis computer code. The steam generator model is comprised of a cylindrical shell and helically coiled tubes. A cold feed water entered the tubes is heated up, evaporates. and finally become a superheated steam with a large amount of heat transferred continuously from the hot compressed water at higher pressure flowing counter-currently through the shell side. For the calculation of tube side two-phase flow field formed by boiling, inhomogeneous two-fluid model is used. Both the internal and external turbulent flows are simulated using the standard k-e model. The conjugate heat transfer analysis method is employed to calculate the conduction in the tube wall with finite thickness and the convections in the internal and external fluids simultaneously so as to match the fluid-wall-fluid interface conditions properly. The numerical calculations are peformed for helically coiled tubes of steam generator at an integral type pressurized water reactor under normal operation. The effects of tube-side inlet flow velocity are discussed in details. The results of present numerical simulation are considered to be physically plausible based on the data and knowledge from previous experimental and numerical studies where available.

  • PDF

이중튜브의 액압 성형특성 연구 (Hydroforming Characteristics of Double Layered Tube)

  • 권승오;이혜경;정기석;문영훈
    • 소성∙가공
    • /
    • 제16권8호
    • /
    • pp.567-574
    • /
    • 2007
  • Double layered tube is assembled with an inner tube and an outer tube, similar in material or not, contacting closely and deforming simultaneously when subjected to external force. For the manufacturing of double layered tube, the hydroforming assembly technology has several advantages. Therefore in this study, hydroforming characteristics of double layered tube was investigated. The free bulge test was performed to produce formability diagrams of double layered tubes at various forming pressure and feeding amounts. The hexagonal shape hydroforming test was also performed to estimate the dimensional accuracies of double layered tube through the corner filling ratio and the gap between inner and outer tube. Besides experimental analyses, the analytical model that can predict internal pressure for the hydroforming of double-layered tube was proposed and experimentally validated.

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제10권3호
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

연직하중을 받는 콘크리트충전 원형강관기둥의 접합부 내력에 관한 연구 (A Study on the Strength and Stiffness of the Concrete Filled Circular Tube Beam to Column Connections under the Gravity Loads)

  • 이명우;최성모;김동규
    • 한국강구조학회 논문집
    • /
    • 제9권4호통권33호
    • /
    • pp.611-623
    • /
    • 1997
  • 연직하중을 받는 콘크리트충전 원형강관기둥 외다이아프램 접합부의 거동을 파악하고자 실험을 통하여 그 내력을 평가하고 각 변수에 따른 영향도를 분석하였다. 이를 위해 다층골조의 보-기둥을 실물크기 1/4규모로 모델화시켜 총 20개의 실험체를 제작하였으며 스티프너 보강유무, 스티프너 폭, 강관두께, 강관과 스티프너의 용접유무 등을 주요변수로 두어 본 연구를 수행하였다.

  • PDF