Browse > Article
http://dx.doi.org/10.12989/scs.2010.10.3.261

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms  

Lee, Seong-Hui (Total Structural Engineering and Construction Ltd (TSEC))
Yang, Il-Seung (Department of Architectural Engineering, Dongshin University)
Choi, Sung-Mo (School of Architectural Engineering, University of Seoul)
Publication Information
Steel and Composite Structures / v.10, no.3, 2010 , pp. 261-279 More about this Journal
Abstract
Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.
Keywords
welded built-up square CFT column; external diaphragm; weld throat thickness; inner anchor;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
1 Fujita, Y., Takahashi, Y., Sugimoto, H., Hashimoto, Y., Nishimura, K. and Arai, T.(1999), "Simplified Exterior Diaphragm Emplyed in Beam to RHS Column Connection", Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, C-1, Structures 3.
2 International Institute of Welding (IIW) (1989), "Design recommendations for hollow section joints-predominantly statically loaded.", IIW Doc. XV-701-89, 2nd ed, IIW Subcommission XV-E, Helsinki, Finland.
3 Kim, Y.J., Shin, K.J. and Kim, W.J. (2008), "Effect of Stiffener Details on Behavior of CFT Column-to-Beam Connections", Int. J. Steel. Struct., 8(2), 119-133.
4 Lee, S.H., Park, J.H., Yeom, K.S., Kim, J.H. and Choi, S.M. (2007), "Experimental study on the structural characteristics of new cold-formed CFT square-type stub columns". Research of the Korean Society of Steel Construction, Academic Conference, 665-668.
5 Morino, S., Uchikoshi, M. and Yamaguchi, I. (2001), "Concrete-filled steel tube column system-its advantages", Int. J. Steel. Struct., 1(1), 33-44.   DOI
6 Architectural Institute of Korea (2004), Concrete-filled steel tube design and construction manual.
7 Satish Kumar, S.R. and Prasada Rao, D.V. (2006), "RHS beam-to-column connection with web opening - experimental study and finite element modeling", J. Constr. Steel. Res., 62(8), 739-746.   DOI   ScienceOn
8 Shin, K.J., Kim, Y.J., Oh, Y.S. and Moon, T.S. (2004), "Behavior of welded CFT column to H-beam connections with external stiffeners", Eng. Struct., 26(13), 1877-1887.   DOI   ScienceOn
9 Wu, L.Y., Chung, L.L., Tsai, S.F., Lu, C.F. and Huang, G.L. (2007), "Seismic behavior of bidirectional bolted connections for CFT columns and H-beams", Eng. Struct., 29, 395-407.   DOI   ScienceOn
10 Zhang, Y., Xu, C. and Lu, X. (2007), "Experimental study of the hysteretic behavior of concrete-filled square thin-walled steel tubular columns", J. Constr. Steel. Res., 63, 317-325.   DOI   ScienceOn
11 Choi, S.M., Kim, D.J., Kim, J.H. and Lee, S.H. (2005), "Experimental study on seismic performance improvement of concrete-filled tubular square column-to-beam connections with combined cross-diaphragm", Int. J. Steel. Struct.(IJOSS), 5(4), 367-375.
12 Architectural Institute of Japan (1990), Guidelines and explanation of steel tube structure design and construction.
13 Architectural Institute of Japan (1997), Design and construction guidelines for concrete-filled steel tube structures.
14 Cheng, C.T. and Chung, L.L.(2003), "Seismic performance of steel beams to concrete-filled steel tubular column connections", J. Constr. Steel. Res., 59(3), 405-426.   DOI   ScienceOn
15 Choi, S.M., Yun, Y.S. and Kim, J.H. (2006), "Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm", Steel. Compos. Struct., 6(4), 303-317.   DOI
16 De Nardin, S. and Ana Lucia, A.L.H.C. (2004), "An experimental study of connections between I-beams and concrete filled steel tubular columns", Steel. Compos. Struct., 4(4), 303-315.   DOI