• Title/Summary/Keyword: external ratio

Search Result 1,202, Processing Time 0.027 seconds

The Relationship of Cash Flow and External Funding in Hospital (의료기관 현금흐름과 외부자금조달 간의 관계)

  • Jung, Yong-Mo;Lee, Yong-Chul;Lim, Jeong-Do
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.87-97
    • /
    • 2010
  • The study analyzed the cash flow and external funding in focusing on the relationship of the two factors in Korean hospitals and some changes in the relationship. The results analyzing this study were summarized as follows: First, the discriminant function of new external funds was generally the ratio of cash flow from operating activities to sales, the ratio of cash flow from investment activities to sales, the ratio of cash flow from financing activities to sales in order. The prediction rate of total discriminant function was more than 92%. Second, in case of Korean hospitals, it was known that the ratio of cash flow from operating activities to sales, particularly the net income to sales was the biggest influencing factor on the decision to external funding.

Effects of the external optical feedback on the DFB-LD modules for 2.5Gbps optical communication system (2.5Gbps 광통신용 DFB-LD 모듈에 대한 광궤환의 영향)

  • 박경현;이중기;한정희;조호성;장동훈;박철순
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.1-14
    • /
    • 1996
  • Effects of the external optical feedback on the optical transmission characteristics were evaluated for 3 kinds of commercialized DFB-LD modules for 2.5Gbps optical communication systems. As a result, intensity noise induced by external optical feedback via generating the external cavity modes deteriorated the transmission performances of sthe DFB-LD modules as much as 1.5dB, 1.2dB, and 1.0dB for the maximum feedback ratio of -8.8dB which corresponds to the worst reflection along the fiber transmission line. Additional penalty of 0.5dB was occurrred when state of polarization of feedback light was adjusted. From the experiments evaluating the isolation ratio of the single polarization optical isolator, decrease of the polarization dependent isolation ratio as much as 10dB from that of specification and the effective isolation ratio as much as 20dB from that of specification was mjor cause of high sensitivity of DFB-LD modules to external feedback. It was suggested that polarization independent optical isolator or single polarization optical isolator with isolation ratio specification of more than 40dB is required for 2.5Gbps DFB-LD modules with complete suppression of external feedback effects.

  • PDF

Comparative Study of Infraspinatus and Posterior Deltoid Muscle Activation According to Angle of External Rotation of Glenohumeral Joint

  • Yang, Dongseok;Choi, Wonho
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2071-2076
    • /
    • 2020
  • Background: Based on the understanding of the muscle activation relationship between the infraspinatus and posterior deltoid muscles to according to the angle of motion during external rotation on glenohumeral joint, effective shoulder joint strengthening exercise for the prevention and rehabilitation of shoulder injury due to muscle strength imbalance can be performed by achieving the ideal muscle activity ratio during exercise. Objectives: To compare and analyze the muscle activation changes and activity ratio of the infraspinatus and posterior deltoid muscles according to the glenohumeral external rotation angle. Design: Quasi-randomized trial. Methods: The study included 48 healthy male and female adults who provided informed consent for participation in the study. All the subjects performed isometric glenohumeral external rotation by setting the angle of motion to 30°, 45°, and 60° using a 5 kg resistance weight pulley. On surface electromyography, the differences in muscle activation and activity ratio between the infraspinatus and posterior deltoid muscles were investigated. Results: A significant difference in muscle activation was found in the comparison between the infraspinatus and posterior deltoid muscles according to the glenohumeral external rotation angle (P<.05). The muscle activation levels of the infraspinatus and posterior deltoid muscles were highest at the external rotation angles of 30° and 60°, respectively. The muscle activity ratio between the infraspinatus and posterior deltoid muscles also showed a significant difference (P<.05) and was highest at the shoulder external rotation angle of 30°. Conclusion: The findings of this study suggest that muscle activity is the highest at the shoulder external rotation angle of 30° in healthy individuals.

A Study on Characteristics and the Back Fire Limit Equivalnce Ratio of Hydrogen Fueled Engine with External Mixture (흡기관분사식 수소기관의 특성 및 역화한계당량비의 해석)

  • Paik, Sung Ho;Lee, Jong Tai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.1
    • /
    • pp.55-62
    • /
    • 1996
  • As an essential step for development of a duel injection hydrogen fueled engine which can obtain high thermal efficiency and power in overall operating range, performance and BFL(back fire limit) equivalance ratio in hydrogen fueled engine with external mixture are investigated. As the results, BFL equivalence ratio in hydrogen fueled engine with external mixture is approximately 0.7. It is deduced that controls of driving conditions are required in transient stage from external mixture type to inner injection type. And in order to increase thermal efficiency, it is also found that BFL equivalence ratio should be expanded as much as possible.

  • PDF

The Effects of PNF Leg Flexion Patterns on EMG Activity of the Trunk (PNF 하지굴곡패턴운동이 체간근육 활성도에 미치는 영향)

  • Kim, Kyung-Hwan;Ki, Kyong-Il;Youn, Hye-Jin
    • PNF and Movement
    • /
    • v.9 no.3
    • /
    • pp.19-24
    • /
    • 2011
  • Purpose : The purpose of this study was to analyze the effect of PNF lower extremity flexion pattern on the eletromyographic (EMG) activity in rectus abdominis, internal oblique abdominal, external oblique abdominal, erector spinae. Methods : Twenty-six healthy adults volunteered to participate in this study. Subjects were required complete following two PNF lower extremity patterns; flexion-adduction-external rotation with knee flexion (D1) and flexion-abduction-internal rotation with knee flexion (D2). A paired t-test was used to determine the influence of the PNF two patterns on muscle activity for each muscle and descriptive statistics was used to determine local/global muscle ratio. Results : The D1 pattern was showed significant rectus abdominis (p<.05) and Median of internal oblique/rectus abdominis ratio was 2.23 and internal oblique/external oblique ratio was 1.53. The D2 pattern showed significant erector spinae (p<.05) and Median of internal oblique/rectus abdominis ratio was 3.06 and internal oblique/external oblique ratio was 1.72. Conclusion : The D1 pattern made rectus abdominis activation increase. The D2 pattern made erector spinae activation increase. As compared D1 and D2 pattern on trunk muscle activation, it's will be useful decision making for the trunk muscle strength and stabilization.

Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside (내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가)

  • Lee, Ju-Yeob;Song, Min-Jeong;Lee, Tai-Gang;Kim, Sun-Woo;Cheon, Deuk-Youm
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

Ultimate Stress of Prestressing Steel in Prestressed Concrete Beams Strengthened by External Prestressing (외부 프리스트레싱으로 보강된 프리스트레스트 콘크리트 보에서 프리스트레싱 강재의 극한응력)

  • Park Sang-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.677-686
    • /
    • 2004
  • This study deals with literature review, developing a predicting equation for the ultimate stress of internal and external prestressing steel, and an experimental test with the parameters affecting the ultimate stress of prestressing steel in prestressed concrete beams strengthened by external prestressing tendons. The proposed predicting equation takes rationally the effect of internal and external prestressing steels into consideration as a function of prestressing steel depth to neutral depth ratio. In the experimental study, prestressed concrete beams strengthened using external steel tendons are tested with the test parameters having a large effect on the ultimate stress of internal and external prestressing steel. The test parameters include internal and external prestressing steel reinforcement ratio and span to depth ratio. The test results are analyzed to confirm the rationality and applicability of the proposed equation for predicting the ultimate stress of internal and external prestressing steel. This research shows that the results obtained by the proposed equation for predicting the ultimate stress agreed very well with the test results.

A Study on Ratio Error and Phase Angle Error Caused by an External Burden in Voltage Transformer (외부부담이 전압변성기의 비오차와 위상각오차에 미치는 영향에 대한 연구)

  • 정재갑;권성원;김규태;김명수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.137-142
    • /
    • 2004
  • A voltage transformer(VT) used for the estabilishment of high voltage national standard, has generally ratio error and phase angle error. Both errors in VT depend critically on values of external burden of VT used. Both ratio ewer and phase angle error in existence of the external burden is calculated. These calculated values are very well consistent with the experimental result. The principle and the measurement method of VT in our institute are also explained.

Automatic Addition Control of the External Carbon Source by the Measurement of ORP in Biological Nitrogen Removal Process (생물학적 질소 제거공정에서 ORP 측정을 통한 외부탄소원의 자동 주입 제어)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.3
    • /
    • pp.383-390
    • /
    • 2012
  • For the cost-effective biological nitrogen removal (BNR) process whose characteristics of influent have low COD/N ratios, the automatic control system for the addition of external carbon based on oxidation-reduction potential (ORP) data in an anoxic reactor has been developed. In this study, it was carried out with a pilot-scale Bardenpho process which was consisted of anoxic 1, aerobic 1, aerobic 2, anoxic 2, aerobic 3 tank and clarifier. Firstly, the correlation coefficient ($R^2$) of the dosage of external carbon source and ORP value was about 0.97. Consequently, the automatic control system using ORP showed that the dosage of external carbon source was decreased by about 20% compared with a stable dosage of 75 mg/L based on the COD/N ratio of the anoxic influent.

Promotion or Prevention? The Moderating Effect of Embedded External Reviews on Consumer Evaluations

  • Ziqiong Zhang;Le Wang;Shuchen Qiao;Zili Zhang
    • Journal of Smart Tourism
    • /
    • v.3 no.3
    • /
    • pp.5-15
    • /
    • 2023
  • Given the increasing information overload among users of online review websites, understanding the manner in which cognitive costs are reduced and efficient information is made reliable has become increasingly important. This study targets a unique consumer review design and explores how reviews from an external peer-to-peer site embedded in an online travel agency (OTA) website influence subsequent evaluation behaviors. The empirical results indicate that (1) embedded external reviews with a high average valence tend to strengthen the influence of the positive evaluation ratio while diminishing the effect of the review volume, and (2) embedded external reviews with a large variance strengthen the positive effect of the review volume while weakening the effect of the positive evaluation ratio on subsequent positive evaluations. The findings provide practical insights for consumers and online platforms.