• 제목/요약/키워드: external magnetic field

검색결과 448건 처리시간 0.035초

고주파 영역에서의 MR 유체 특성연구 (Material Characterization of MR Fluids at High Frequencies)

  • 박경미;김재환;최승복;김경수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.210-215
    • /
    • 2002
  • MR(Magnetorheogical) fluid composed of fine iron powders dispersed in silicon oil is utilized to many smart structures and devices because of its significant rheological property change by the application of an external magnetic field. When we deal with the shock wave attenuation of warship structures, we should be able to characterize the high frequency behavior of MR fluids. So far, however, many efforts have been focused on the material characterization of MR fluids at low frequencies below 100Hz. In this paper, the MR fluid property characterization at high frequency region is performed. An experimental setup based on wave transmission technique is made and the storage modulus as well as the loss modulus of MR fluids are found from the measured data of speed sound and attenuation. Details of the experiment are addressed and the obtained storage and loss moduli are addressed at $50kHz{\sim}100kHz$.

  • PDF

Charicteristics of HF 10-cm Type Grid Ion Source for Inert and Chemically Reactive Gases.

  • Chol, W.K;Koh, S.K;Jang, H.G;Jung, H.J;Kondranin, S.G.;Kralkina, E.A.;Bougrov, G.E.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1996년도 제10회 학술발표회 논문개요집
    • /
    • pp.102-102
    • /
    • 1996
  • This paper represents a new type low power High Frequency technological ion source (HF TIS) for ion - beam processing: the surface modification of materials, cleaning of surface, sputtering, coating of thin films, and polishing. The operational principle of HF TIS is based on the excitation of electrostatic waves in plasma located in the external magnetic field. Low power HF TIS with diameter 92 rom gives the opportunity to obtain beams of inert and chemically reactive gases with currents range from 5 to 150 mA (current density $0.015\;~\;3.5\;mA/\textrm{m}^2$) and ion beam energy 100 ~ 2500 eV at a HF power level 10 ~ 150 W. Three grid concave type ion optical system (IOS) is used for extraction and formation ofion beam.n beam.

  • PDF

기둥형 결정립 구조를 지닌 $MgB_2$ 박막에서 자속고정 현상 (Flux Pinning in $MgB_2$ Film with Columnar Grains)

  • 김동호;김혜영;황태종;이상한;성원경;강원남
    • Progress in Superconductivity
    • /
    • 제9권2호
    • /
    • pp.173-176
    • /
    • 2008
  • [ $MgB_2$ ] films grown by hybrid physical chemical vapor deposition under appropriate growth conditions commonly exhibit columnar grain structure. The grain boundaries between adjacent columnar grains have been reported to be good flux pinning centers. In this work, we measured the angular dependence of critical current density ($J_c$) and observed the enhanced flux pinning when an external magnetic field was aligned parallel to the columnar direction. This $J_c$ was almost comparable to the $J_c$ for intrinsic pinning case up to 1 T at low temperatures, indicating that grain boundary pinning is very effective. At high fields, however, $J_c$ decreased rapidly resulting from the fact that the density of flux pinning centers provided by grain boundaries was outnumbered by the flux density.

  • PDF

전기도금된 Cu-Sn과 Ni preplated frame의 특성 비교 (Comparison of the Characteristics of Cu-Sn and Ni Pre-Plated Frames Prepared by Electro-Plating)

  • 이대훈;장태석;홍순성;이지원;양형우;한병근
    • 한국표면공학회지
    • /
    • 제39권6호
    • /
    • pp.276-281
    • /
    • 2006
  • In order to improve the performance of PPFs (Pre-Plated Frames), a PPF that employed a Cu-Sn alloy instead of conventionally used Ni was developed and then its properties were investigated. It was found that the electoplated Cu-Sn alloy layer was a mixture of uniformly distributed fine crystallites, resulting In better wettability and crack resistance than those of Ni PPF. Moreover, as in Cu/Ni/Pd/Au PPF, migration of copper atoms from the base metal to the top of the Cu/Cu-Sn/Pd/Au PPF surface was not found although the Cu-Sn layer itself contained considerable amount of copper. It was expected that, by using the newly developed Cu-Sn PPF, any possible heat generation and signal interrupt caused by an external electro-magnetic field could be reduced because the Cu-Sn layer was paramagnetic, i.e., nonmagnetic.

MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법 (Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images)

  • 김형진;서광덕
    • 한국정보통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.948-958
    • /
    • 2010
  • MRI 시스템이 수집하는 인체신호는 매우 미약하기 때문에 영상화 과정을 거치면서 외부 잡음이나 시스템 불안정성에 의한 영향을 쉽게 받을 수 있다. 따라서 본 논문에서는 저 자장 MRI시스템에서 RF 수신코일의 디자인적 요소에 의해 발생되는 불균일성을 분석하여 영상의 균일도 향상 기법을 제안한다. 본 논문에서는 MRI영상의 신호강도 불균일성을 보정하기 위한 방법 중에서 팬텀 데이터를 이용하여 확장된 크기를 갖는 3차원 bias 볼륨 데이터를 획득하기 위한 방법을 제안함으로써 다양한 크기를 갖는 영상의 보정이 가능하도록 하였다. 제안된 bias 데이터의 최적화 기법을 적용하여 실험을 수행한 결과 단일 bias 데이터의 사용으로 다양한 영상법에 의한 영상을 효과적으로 보정할 수 있음을 확인 하였다.

Bi-2223 고온 초전도 선재의 교류손실에 관한 연구 (The a.c. losses in (Bi,Pb)2Sr2Ca2Cu3Ox silver-sheathed superconducting tapes)

  • 강형구;추용;이찬주;고태국;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.822-824
    • /
    • 2000
  • To apply HTS to AC devices, it is necessary that study theoretically and experimentally to analyze the AC losses. It should be investigated the theoretical mechanisms precede the actual experiments. Because the AC losses cause some complicated troubles in AC machines, we can design the machines properly. In this study, firstly we analyze the basic cause of AC losses by investigating the several loss factors, secondly measure the AC losses of HTS by using Magnetization. Technique and this results show that AC losses of HTS is tenuous than those of general materials used in power system. Consequently we can compare the actual results with the theoretical results. And we find that AC losses of HTS are related to the amplitude of external magnetic field and the frequency. Through this study, we find that it is possible to apply the results by Magnetization. Technique to the AC power system, to the design of AC machine, to design of HTS proper to the foretold AC losses.

  • PDF

Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구 (Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography)

  • 장인동;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

A Laterally-Driven Bistable Electromagnetic Microrelay

  • Ko, Jong-Soo;Lee, Min-Gon;Han, Jeong-Sam;Go, Jeung-Sang;Shin, Bo-Sung;Lee, Dae-Sik
    • ETRI Journal
    • /
    • 제28권3호
    • /
    • pp.389-392
    • /
    • 2006
  • In this letter, a laterally-driven bistable electromagnetic microrelay is designed, fabricated, and tested. The proposed microrelay consists of a pair of arch-shaped leaf springs, a shuttle, and a contact bar made from silicon, low temperature oxide (LTO), and gold composite materials. Silicon-on-insulator wafers are used for electrical isolation and releasing of the moving microstructures. The high-aspect-ratio microstructures are fabricated using a deep reactive ion etching (DRIE) process. The tandem-typed leaf springs with a silicon/gold composite layer enhance the mechanical performances while reducing the electrical resistance. A permanent magnet is attached at the bottom of the silicon substrate, resulting in the generation of an external magnetic field in the direction vertical to the surface of the silicon substrate. The leaf springs show bistable characteristics. The resistance of the pair of leaf springs was $7.5\;{\Omega}$, and the contact resistance was $7.7\;{\Omega}$. The relay was operated at ${\pm}0.12\;V$.

  • PDF

유한요소법과 상태방정식을 이용한 포워드 컨버터의 동작 특성 해석 (Characteristics Analysis of a Forward Converter by Finite Element Method and State Variables Equation)

  • 박성진;권병일;박승찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.467-475
    • /
    • 1999
  • This paper presents an analysis method of a forward converter, using both the finite element method considering the external circuit and a state variables equation. The converter operates at 50kHz and its one period is divided into two modes for the simplicity of the analysis. In the first mode, the switching transistor turns on and an input power is transferred into the load by the electromagnetic conversion action of a ferrite transformer. In the second mode, the switching transistor turns off and the stored energy in an inductor is delivered to the load, and the transformer core is demagnetized by the reset winding current. In this paper, time-stepping finite element method taking into account the on-state electrical circuit of the converter in used to analyze both the electrical circuit and electromagnetic field of the magnetic device during the first mode and the demagnetization period of the transformer core. Then a state variables equation for the circuit which the inductor current flows is constituted and solved during the second mode. As a result, the simulation results have been good agreement with the results obtained form experiment.

  • PDF

Spatial mapping of screened electrostatic potential and superconductivity by scanning tunneling microscopy/spectroscopy

  • Hasegawa, Yukio;Ono, Masanori;Nishio, Takahiro;Eguchi, Toyoaki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.12-12
    • /
    • 2010
  • By using scanning tunneling microscopy/spectroscopy (STM/S), we can make images of various physical properties in nanometer-scale spatial resolutions. Here, I demonstrate imaging of two electron-correlated subjects; screening and superconductivity by STM/S. The electrostatic potential around a charge is described with the Coulomb potential. When the charge is located in a metal, the potential is modified because of the free electrons in the host. The potential modification, called screening, is one of the fundamental phenomena in the condensed matter physics. Using low-temperature STM we have developed a method to measure electrostatic potential in high spatial and energy resolutions, and observed the potential around external charges screened by two-dimensional surface electronic states. Characteristic potential decay and the Friedel oscillation were clearly observed around the charges [1]. Superconductivity of nano-size materials, whose dimensions are comparable with the coherence length, is quite different from their bulk. We investigated superconductivity of ultra-thin Pb islands by directly measuring the superconducting gaps using STM. The obtained tunneling spectra exhibit a variation of zero bias conductance (ZBC) with a magnetic field, and spatial mappings of ZBC revealed the vortex formation [2]. Size dependence of the vortex formation will be discussed at the presentation.

  • PDF