Browse > Article
http://dx.doi.org/10.6109/jkiice.2010.14.4.948

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images  

Kim, Hyoung-Jin (연세대 전산학과, (주)에이아이랩)
Seo, Kwang-Deok (연세대 컴퓨터정보통신공학부)
Abstract
Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.
Keywords
Nonuniformity correction of MRI image; Medical image processing; Bias correction; 3D visualization;
Citations & Related Records
연도 인용수 순위
  • Reference
1 P. Narayana, W. Brey, M. Kulkarni, and C. Sievenpiper, "Compensation for surface coil sensitivity variation in magnetic resonance imaging," Magnetic Resonance Imaging, Vol. 6, pp. 271-274, 1988.   DOI   ScienceOn
2 M. Styner, C. Brechbuhler, G. Szekely, and G. Gerig, "Parametric estimate of intensity inhomogeneities applied to MRl," IEEE Trans. Medical Imaging, Vol. 19, No. 3, pp.153-165, 2000.   DOI   ScienceOn
3 B. Likar, M. A. Viergever, and F. Pemus, "Retrospective correction of MR intensity inhomogeneity by information minimization," IEEE Trans. Medical Imaging, Vol. 20, No. 12, pp. 1398-1410, 2001.   DOI   ScienceOn
4 E. Ardizzone, R. Pirrone, and O. Gambino, "Frequency Determined Homomorphic Unsharp Masking Algorithm on Knee MR Images," Lecture Notes in Computer Science, Vol. 3617, 2005.
5 D. Wicks, G. Barker, and P. Tofts, "Correction of intensity nonuniformity in MR images of any orientation," Magnetic Resonance Imaging, Vol. 11, No. 2, pp. 183-196, 1993.   DOI   ScienceOn
6 E. Haacke, "Magnetic Resonance Imaging: Physical Principles and Sequence Design," New York: John Wiley & Sons Inc., 1999.
7 DICOM standard (DICOM PS 3-2008), National Electrical Manufacturers Association.
8 D. Mitchell, "MRl Principles," W.B. Saunders Company, 2004.
9 Z.Hou, "A review on MR image intensity inhomogeneity correction," International Journal of Biomedical Imaging, Vol. 2006, Article ID 49515, pp. 1-11, 2006.
10 L. Axel, J. Costantini, and J. Listerud, "Intensity correction in surface coil MR imaging," American Journal of Roentgenology, Vol. 148, pp. 418-420, 1987.   DOI   ScienceOn
11 R. Guillemaud, "Uniformity Correction with Homomorphic Filtering on Region of Interest," IEEE Int. Conference on Image Processing, Vol. 2, pp. 872-875, Oct. 1998.
12 M. Tincher, C. R. Meyer, R. Gupta, and D. M. Williams, "Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI," IEEE Trans. Medical Imaging, Vol. 12, No. 2, pp. 361-365, Jun. 1993.   DOI   ScienceOn