• 제목/요약/키워드: external insulation system

검색결과 74건 처리시간 0.032초

초고압 GIS의 CT 단자부를 이용한 Semi-내장형 UHF PD 센서 개발 및 적용 (Development and application of the semi-internal type UHF PD sensor for Gas Insulated Switchgear)

  • 강원종;이도훈;이용희;신양섭;김영근;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2038-2039
    • /
    • 2007
  • In this work, a novel semi-internal type UHF PD sensor has been proposed and related investigations has been performed in order to detect the partial discharges that could be possibly produced at the insulation system of the gas insulated switchgear(GIS). This sensor was designed to mount on the CT terminal hole of GIS using the spiral antenna theory. Therefore this type sensor can be install on GIS during the power apparatus has been operation and better sensitivity compare to the commercial external type UHF PD sensor.

  • PDF

전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구 (Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy)

  • 김명수;김성철
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1735-1742
    • /
    • 2018
  • The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

경량기포콘크리트(ALC) 패널을 건축물 외장 커튼월에 적용을 위한 도료의 기초적 연구 (Applications and Analysis of Exterior Paints for the Curtain Wall Panel System based on the Autoclaved Lightweight Concrete(ALC))

  • 이용수;라현주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권3호
    • /
    • pp.59-66
    • /
    • 2012
  • Autoclaved Lightweight Concrete(ALC) features such as a high performance insulation, the fire resistance, the advantage of easy handing construction, and lightweight panels applied the curtain wall system. ALC materials are certified as non-toxic environmental and eco-friendly productions. But ALC external panels mixed with blast furnace slag pounder and silica fume have to be coated with a stucco compound or plaster because of resisting the ambient environment. This study is that mixing tests to evaluate a performance analysis of exterior paints to be make-up pigments(organic or inorganic) coated with panel surface. Testing compared by KS F 2476; flow test, KS F 2426; compression strength test, KS F 2762; bond strength test. In results, the case of the inorganic binder, ratio of alumina cement : anhydrite is 90:10 to 80:20 at the highest level of intensity. In the case of the organic binder, adhesive strength rating at surface of ALC, the pullout strength is below 0.5 $N/mm^2$ but the normal concrete is over 2.0$N/mm^2$. A contents ratio of EVA resin is more than 3% and then bond strength is effectively.

직교이방성 복합재료의 극저온 재료 물성치를 고려한 LNG CCS의 강도 평가에 관한 연구 (Strength Assessment of LNG CCS using Strength Analysis Method for Composite Materials)

  • 정한구;양영순
    • 대한조선학회논문집
    • /
    • 제51권2호
    • /
    • pp.114-121
    • /
    • 2014
  • Liquefied natural gas(LNG) cargo containment system(CCS) has the primary function of ensuring both adequate structural safety with respect to sloshing load which is defined as a violent behaviour of the liquid contents in CCS due to external forced motions and thermal insulation keeping natural gas below its boiling point. Among different LNG CCS types such as independent B-type and membrane ones, Mark III CCS is considered in this paper to perform its strength assessment. Mark III CCS plate is designed and constructed by stacking various non-metallic engineering materials such as plywood, triplex, reinforced PU foam that are supported by series of mastic upon inner steel hull structure. From the viewpoint of structural analysis, this plated structure is treated as a laminated composite structure showing complex structural behaviour under external load. Advanced finite element models of Mark III CCS plate is generated and used in conjunction with ultimate strength based failure criteria from laminated composite mechanics for the strength assessment. The strength assessment is performed within the initial failure state of Mark III CCS plate. Results provide failure details such as failure locations and loads. Finally obtained results are reviewed using the loads from acceptance criteria suggested by classification.

Development of a Mobile Robot System for Visual Inspection under Hot Environment

  • Park, Sang-Deok;Lee, Ho-Gil;Kim, Hong-Seok;Son, Woong-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1506-1510
    • /
    • 2004
  • A mobile robot system is developed to inspect the condition of industrial facilities under hot environment. The mobile robot is equipped with internal and external heat insulating material, an internal cooling mechanism, two CCD cameras, wireless communication devices for both the control and image signals, and an embedded controller. The portable controller is equipped with two joysticks for both the mobile robot and the inspection CCD camera, an LCD monitor, and several buttons. The developed mobile robot travels on the internal floor in hot furnaces by operators' joystick operation, captures the images of facilities in the furnaces using a zoom CCD camera, and sends the images to the portable controller through wireless communication. The mobile robot can be operated without any problem under hot environment less than 400$^{\circ}C$ in 30 minutes. This kind of automatic inspection mobile robot can be helpful to prevent significant troubles of industrial facilities without danger of human beings under harmful environment.

  • PDF

인가전압에 따른 모의변압기의 HFPD 특성분석 (HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage)

  • 김덕근;임영삼;임장섭;문채주;이진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로- (Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West-)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.

SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험 (Development and Performance Test of SOFC Co-generation System for RPG)

  • 이태희;최진혁;박태성;최호윤;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

1kW 고체산화물 연료전지(SOFC) 시스템 설계 및 자열운전 (Design and Self-sustainable Operation of 1 kW SOFC System)

  • 이태희;최진혁;박태성;유영성;남석우
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.384-389
    • /
    • 2009
  • KEPRI (Korea Electric Power Research Institute) has studied planar type solid oxide fuel cell (SOFC) stacks using anode-supported cells and kW class co-generation systems for residential power generation. In this work, a 1 kW SOFC system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a SOFC stack made up of 48 cells, a fuel reformer, a catalytic combustor, and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation in that system. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. When the 1 kW SOFC stack was tested using hydrogen at $750^{\circ}C$, the stack power was about $1.2\;kW_e$ at 30 A and $1.6\;kW_e$ at 50 A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_e$ with hydrogen and $1.2\;kW_e$ with city gas respectively. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water.

고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구 (A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD))

  • 김지홍;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF