• Title/Summary/Keyword: external electrode

Search Result 264, Processing Time 0.033 seconds

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.

Influence on EDM Surface with the Copper and Graphite Electrode According to the Discharge Energy (방전에너지에 따라 동전극과 흑연전극이 방전가공면에 미치는 영향)

  • Choi, Jae-Yong;Jeon, Eon-Chan;Jeong, Jae-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.53-59
    • /
    • 1997
  • This study has been performed to inmvestigate MRR(metal removal rate), REW(relative electrode wear), surface roughness, heat transumutation layer and microhardness distribution in cross-section of the machined surface with various pulse-on duration and peak pulse current, using the copper and graphite electrode on the heat treated STD11 which is extensively used for metallic molding steel with the EDM. The results obtained are as follows; a) There exists critical pulse-on duration(If Ip equals 5A, .tau. on is 50 .mu. s) which shows the the maximum MRR in accordance with peak oulse current and the MRR decreases when the pulse-on duration exceeds the critical pulse-on during because of the abnormal electric discharge. b) Safe discharge is needed to make maximum of MRR and the metalic organization must be complicated for discharge induction. c) Graphite has much more benefits than copper electrode when rapid machining is done without electrode wear. d) The most external surface has the highest microhardness because of car- burizing from heat analysis of the dielectric fluid and the lower layar of the white covered layer has lower microhar dness than base matal because of softening.

  • PDF

Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes (외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.

Clinical Use of the Pace-maker in four cases (Pace-maker 사용 4예 경험)

  • 이성구
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.219-228
    • /
    • 1980
  • The heart block and bradyarrhythmia with or without Stokes-Adams attacks are serious, usually terminal events and the immediate mortality is very high. Stimulation with an artificial pacemaker is now an accepted form of treatment in cases of Stokes-Adams syndrome in which medication in unable to produce any lasting improvement. Permanent pacemaker therapy is indicated in these circumstances. The purpose of this report is to describe the successful use of pacemaker in 3 cases of Stokes-Adams syndromes and a case of sinoatrial block with bradyarrhythmia at the Department of Thoracic and Cardiovascular Surgery, Kyungpook National University School of Medicine. Electrode catheter was passed through the right external jugular vein and attached to the endocardial surface of the right ventricle. In case 1, fixed type generator was used at first and for the case 2, 3, 4, and case 1 at second, demand type generators were used. The bipolar electrode catheters were used for the three cases and unipolar electrode catheter for case 4. The results of immediate and late period were satisfactory.

  • PDF

Stress Properties in Multilayer Piezoelectric Ceramic Actuators using Finite Element Analysis (유한요소 해석을 이용한 적층 압전 세라믹 액츄에이터의 응력 특성)

  • 홍재일
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.963-968
    • /
    • 1998
  • The stress distribution in multilayer piezoelectric ceramic actuators was investigated by Finite element analysis. The y direction stress was concentrated at electrode tip. The y direction maximum stress was decreased to 4.9$\times10^ 7 N/m^2$ with internal electrode gap(a) until 0.4 mm and was not much difference with external electrode thickness(c). The stress distribution with internal layers was almost same and the stress distribution of load condition was higher than that of no load condition The y direction maximum stress increased with the number of layer and saturated at 260 layers. In the case of defective actuator, the stress distribution was disconnected around the defect and larger than that of normal actuator.

  • PDF

The formation of nano pillar arrays with p-type silicon using electrochemical etching (Electrochemical etching을 이용한 P형 실리콘에서의 nano pillar arrays 형성)

  • Ryu, Han-Hee;Kong, Seong-Ho;Kim, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1529_1530
    • /
    • 2009
  • The process conditions for fabricating p-type silicon pillars were optimized by controlling current density, bath temperature. To get best process flexibility for pillar arrays formation, three factors affecting pillar formation were changed. First, the solution bath was designed to keep constant temperature during the experiment irrespective of external temperature. Second, the counter Pt electrode was changed from rod type to mesh to obtain uniform distribution of current density. Third, Cr-Cu alloy electrode instead of Cu was used to increase electrode current density.

  • PDF

The Characteristics of Multi Gap Type Ozonizer (다중 간극형 오존발생장치의 특성)

  • 김금영;문경수;전병준;박용권;김상구;김영훈;김영길;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.145-148
    • /
    • 1999
  • In this paper, multi gap type ozonizer(MGO) has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: $\circled1$ The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. $\circled2$ The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

The Characteristics of Showering Discharge Type Ozonizer (Showering Discharge형 오존발생장치의 특성)

  • Kim, Keum-Yeung;Mun, Kyung-Su;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Jeon, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2248-2250
    • /
    • 1999
  • In this paper, showering discharge type ozonizer has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flux and discharge power.

  • PDF