• Title/Summary/Keyword: exterior fire

Search Result 121, Processing Time 0.024 seconds

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.

Redrying Fire - Retardant - Treated Structural Plywood (구조용(構造用) 내화처리(耐火處理) 합판(合板)의 재건조(再乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Schaffer, E.L.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.1-21
    • /
    • 1981
  • Exterior grades of Douglas-fir and aspen plywood were impregnated with interior fire-retardant chemicals and redried under low-, intermediate-, and high-temperature drying conditions. Fire-retardant treatments included borax-boric acid, chromated zinc chloride, minalith, pyresote, and a commercial formulation. Drying processes included kiln and press-drying. Evaluated were drying rates and defects generated. The borax-boric acid and the commercial treatments redried at rates similar to water-treated controls. Other salt treatments were significantly slower drying and more defect prone. Chromated zinc chloride treatment was consistently the slowest drying and most defect prone. Press drying was three times faster at an equivalent temperature level. However, thickness shrinkage doubled because of 50 1b/in. platen pressure.

  • PDF

Mass Flow Rates and Performance of Natural Smoke Ventilators in High-rise Buildings (초고층건물에서 배연창의 풍량해석 및 배연성능)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.91-97
    • /
    • 2009
  • The mass flow rates and performance of natural smoke ventilators in high-rise buildings with 40, 80, 120 stories were evaluated using CONTAMW tool. The results showed that only limited part of smoke ventilators can have positive exhaust flow in high-rise buildings due to stack effect and wind velocities. In the higher story buildings larger stack effect can overcome outside strong wind effect to give more ventilation performance. The air tightness of the building have strong effect on the exhaust performance of the ventilators to give lower performance with loose air tightness of the exterior walls.

Analysis on the Falling Risk of Building Electric Shutter and Reduction Measures (건축물 전동셔터 추락 리스크 분석 및 저감 방안)

  • Jung, Young-Min;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.295-296
    • /
    • 2021
  • With the recent diversification and complication of buildings, the functions of building are also developing. As much as the development of buildings, the machine or equipment used for them is also developing. Thus, all sorts of domestic/foreign industrial facilities and fire stations in the whole nation are using the electric shutter that could meet the insulation just like the exterior wall of general buildings, for bringing-in/storage and crime prevention/fire prevention. Currently, various types of electric shutters are used. Such wrong operation and poor management are causing many panel-falling accidents. This study researched the reduction of electric shutter panel-falling risk by reviewing the domestic/foreign laws and standards, and researching the new safety equipment. First, the causes for falling and accident types were drawn by analyzing the cases of electric shutter accidents. After that, a checklist as the measures for reducing the falling of electric shutter in building was suggested by analyzing the items for the inspection of electric shutter.

  • PDF

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

A Study on Combustion Experiments of Color Nonwoven (칼라 부직포의 연소실험에 관한 연구)

  • Min, Se-Hong;Im, Sang-Bum
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • Experiments of Cone calorimeter test and Lift spread flame apparatus test are carried out in order to appraise fire hazard in color nonwoven used mostly on the spot in construction works. As the result, in color nonwoven combustibility is discovered not firing flame in surface, but firing under state of combustible gas occuring in the state of melting. In the case of Lift spread flame apparatus test, color nonwoven is very brittle which almost no flame spread owing to contracting and break by firing strength. The following data are agree with basis: total heat release is 2.66 MJ/$m^2$, limited combustible material (10 min) of incombustible rating appraisal in interior material of building, and incombustible materials (5 min) 8 MJ/$m^2$ in spite of the above data mentioned, those data are only as basis of interior finish, and so I cannot judge color nonwoven have incombustible rating retain through the above data. Accordingly, the basis of incombustible rating and experiment method about exterior finish must be arranged also.

Treatment of Whitening of a Car TPE Component (자동차용 TPE 부품의 백화 처리)

  • Choi, Sung-Seen;Chung, Hye-Seung;Joo, Yong-Tae;Min, Byung-Kwon;Lee, Seong-Hoon
    • Elastomers and Composites
    • /
    • v.45 no.2
    • /
    • pp.94-99
    • /
    • 2010
  • 340 nm UV radiation of $2500\;kJ/m^2$ irradiated a thermoplastic elastomer (TPE) specimen used for interior and exterior materials of a car. After the UV irradiation, the black sample surface was changed to gray. Materials on the aged sample were collected and analyzed using GC/MS, but significant materials were not found. Lots of small cracks were found on the aged specimen surface. Whitening phenomenon of the aged sample disappeared by brushing or searing with a fire on the aged surface. After brushing or searing with a fire, small cracks on the surface vanished. Samples before and after the aging, and the treated samples with brush or fire were analyzed using image analyzer, SEM, EDX, and ATR and the results were compared. The vanished whitening phenomenon by brushing or searing was explained with filling the small cracks by polypropylene of TPE.

A Study on Functionality Evaluation of Profit Model for Remodeling of Apartment House (공동주택 리모델링을 위한 수익모델의 기능성 평가 연구)

  • An, Min-Jae;Pyo, Jin-Myung;Kim, Eui-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.107-113
    • /
    • 2005
  • This study analyzes remaining repair rate and applied repair rate with the presentation of profit model for the purpose of pursuing maximization of added value through remodeling of apartment house. Objects of remodeling and item applying the whole replacement of functionality evaluation items include exterior of building (3 items maintaining the current conditions, 8 items requiring the whole replacement), water supply/sanitary/gas/ventilation facilities (6 items maintaining the current conditions, 6 items requiring the whole replacement, electric/fire fighting/elevator facilities (8 items maintaining the current conditions, 20 items requiring the whole replacement) and heating/water heater facilities (2 items requiring the whole replacement).

Literatural study of the cause and mechanism of Eye Disease (眼病의 病因 病機에 對한 文獻的 考察)

  • Gang, Seung-Won;No, Seok-Seon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.5 no.1
    • /
    • pp.27-44
    • /
    • 1992
  • The cause and mechanism of eye diseases are follow in biblography. The etiological factor of eye diseases are nearly caused by heat. It is important to distinguish deficiency and substance. In external etiologic factors wind-fever is most of all in six exogenous factors. In internal etiologic factors xu(deficiency) of kidney, blood and fire of seven emotions are lots. In factors other than the internal and external, eating greasy food and hyper-caloric food are a lot of case. In relation with the yin-yang andxu-shi, ther are a lot of eye diseases symptom as dark-dizziness due to the yin-xu of hepatic-kidney. According to eight principles of differentiation of syndromes, syndromes of exterior, heat, shi, almost fall into the category of yang and syndromes of interior, cold, xu, nearly fall into the category of yin. In interior treatment, inducing wind and clearing heat, using Qi and tonifying blood, tonifying and suing of hepatic-kid ney are useful and often used treatment.

  • PDF

Study on the origin and theoretical foundation of I Dong-won(李東垣)'s pulse diagnosis distinguishing internal and external injuries(內外傷辨脈法) (이동원(李東垣) 내외상변맥법(內外傷辨脈法)의 유래와 이론적 근거에 대한 고찰)

  • Jang, Woo-Chang
    • Journal of Korean Medical classics
    • /
    • v.20 no.2
    • /
    • pp.137-145
    • /
    • 2007
  • Pulse diagnosis that distinguishes internal injury from external injury by comparing the left and right of the chon pulse was formed in the process of Naegyoung's pulsation theory of ST9 and LU9 being assimilated into diagnostic method by taking chon pulse. The founder of school of internal injury, I Dong-won, expanded the horizon for this method to be widely used in clinical practice by especially explaining the specific application and theoretical background. According to him, pulse at ST9 which means chon pulse at the left hand, is bigger than the chon pulse at the right hand, it reflects external injury. Bigger "entrance pulse", a chon pulse at the right hand means internal injury. The reason is the left side of the body is a path for Yanggi so it controls the exterior part and the right side of the body is a path for Eumgi to descend so it controls the interior part. Internal injury develops as the spleen and stomach get injured. If the spleen and stomach is damaged essence derived from food cannot ascend to the stomach and will flow back to the lower part. As a result, fire of Eum type formed at the lower part will shoot up to the upper part and manifests external injury-like exterior syndromes. In this case, evidence distinguishing between internal and external injury is the fact that right hand pulse is bigger than the left hand. The important reason for distinguishing between internal and external injury is because when treating external injury caused by excess syndrome, pathogenic Gi should be dispelled. However, treating internal injury cased by deficiency syndrome, requires promoting the primordial Gi.

  • PDF