• Title/Summary/Keyword: exterior and interior

Search Result 894, Processing Time 0.027 seconds

Accuracy Assessment of Aerial Triangulation of Network RTK UAV (네트워크 RTK 무인기의 항공삼각측량 정확도 평가)

  • Han, Soohee;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.663-670
    • /
    • 2020
  • In the present study, we assessed the accuracy of aerial triangulation using a UAV (Unmanned Aerial Vehicle) capable of network RTK (Real-Time Kinematic) survey in a disaster situation that may occur in a semi-urban area mixed with buildings. For a reliable survey of check points, they were installed on the roofs of buildings, and static GNSS (Global Navigation Satellite System) survey was conducted for more than four hours. For objective accuracy assessment, coded aerial targets were installed on the check points to be automatically recognized by software. At the instance of image acquisition, the 3D coordinates of the UAV camera were measured using VRS (Virtual Reference Station) method, as a kind of network RTK survey, and the 3-axial angles were achieved using IMU (Inertial Measurement Unit) and gimbal rotation measurement. As a result of estimation and update of the interior and exterior orientation parameters using Agisoft Metashape, the 3D RMSE (Root Mean Square Error) of aerial triangulation ranged from 0.153 m to 0.102 m according to the combination of the image overlap and the angle of the image acquisition. To get higher aerial triangulation accuracy, it was proved to be effective to incorporate oblique images, though it is common to increase the overlap of vertical images. Therefore, to conduct a UAV mapping in an urgent disaster site, it is necessary to acquire oblique images together rather than improving image overlap.

Detection of the Unified Control Points for RPC Adjustment of KOMPSAT-3 Satellite Image (KOMPSAT-3 위성영상의 RPC 보정을 위한 국가 통합기준점 탐지)

  • Lee, Hyoseong;Han, Dongyeob;Seo, Doochun;Park, Byungwook;Ahn, Kiweon
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.829-837
    • /
    • 2014
  • The KOMPSAT-3 can acquire panchromatic stereo image with 0.7 m spatial resolution, and provides Rational Polynomial Coefficient (RPC). In order to determine ground coordinate using the provides RPC, which include interior-exterior orientation errors, its adjustment is needed by using the Ground Control Point (GCP). Several thousands of national Unified Control Points (UCPs) are established and overall distributed in the country by the Korean National Geographic Information Institute (NGII). UCPs therefore can be easily searched and downloaded by the national-control-point-record-issues system. This paper introduced the point-extraction method and the distance-bearing method to detect of UCPs. As results, the distance-bearing method was better detected through the experiment. RPC adjustment using this method was compared with that by only one UCP and GCPs using GPS. The proposed method was more accurate than the other method in the horizontal. As demonstrated in this paper, the proposed UCPs detection method could be replaced GPS surveying for RPC adjustment.

A Level-set Parameterization for Any 3D Complex Interface Related to a Fire Spread in Building Structures (복잡한 CAD 형상의 매개변수화를 통한 3차원 경계면 레벨-셋 알고리즘 개발 및 적용)

  • Kim, Hyun-Jun;Cho, Soo-Yeong;Lee, Young-hun;Yoh, Jai-ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.2
    • /
    • pp.135-146
    • /
    • 2020
  • To define an interface in a conventional level-set method, an analytical function must be revealed for an interfacial geometry. However, it is not always possible to define a functional form of level sets when interfaces become complex in a Cartesian coordinate system. To overcome this difficulty, we have developed a new level-set formalism that discriminates the interior from the exterior of a CAD modeled interface by parameterizing the stereolithography (STL) file format. The work outlined here confirms the accuracy and scalability of the hydrodynamic reactive solver that utilizes the new level set concept through a series of tests. In particular, the complex interaction between shock and geometrical confinements towards deflagration-to-detonation transition is numerically investigated. Also, a process of flame spreading and damages caused by point source detonation in a real-sized plant facility have been simulated to confirm the validity of the new method built for reactive hydrodynamic simulation in any complex three-dimensional geometries.

A Study on the Measurement of Axial Cracks in the Magnetic Flux Leakage NDT System (자기누설 비파괴 검사 시스템에서 축방향 미소결함 측정에 관한 연구)

  • Kim, Hui-Min;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu;Koo, Sung-Ja
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • From among the NDT (Non-Destructive Testing) methods, the MFL (Magnetic Flux Leakage) PIG (Pipeline Inspection Gauge) is especially suitable for testing pipelines because the pipeline has high magnetic permeability. MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is difficult to detect the crack which occured by exterior-interior pressure difference in pipelines and the shape of crack is very long and narrow. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The CMFL (Circumferential MF) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). By Simulating and Measuring the magnetic leakage field, it is possible to detect of axial cracks in the pipeline.

Inelastic Behavior of Beam-Column Joints Composed of RC Column and RS Beams (RC 기둥과 RS 보로 이루어진 보-기둥 접합부의 비탄성 거동)

  • 김욱종;윤성환;문정호;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.734-741
    • /
    • 2002
  • An experimental study was carried out for beam-column joints composed of RC column and RS beams. The purpose of this study is to examine the inelastic seismic behavior for the RC-RS connection. Two interior and one exterior beam-column assemblies with variable moment ratios were tested. Experimental results showed that strength and deformability except stiffness were satisfactory. It is considered that the lack of stiffness was due to the slipping of steel beam from RS beam. The behavioral characteristics of the RC-RS connection were evaluated according to the quideline suggested by Hawkins et al. Nominal strength at 5 % joint distortion was not satisfactory, but all the other requirements, such as strength preserving capability, energy dissipation, and initial stiffness and strength ratios after peak load were satisfactory compared with the guideline. Thus it was concluded that the RC-RS connections can maintain ductility with excellent energy-dissipating capacity if being provided with appropriate reinforced structural system such as RC core wall for the initial lateral stiffness.

Field Application of 80MPa High Strength Fire Resistant Concrete using Ternary Blended Cement (설계강도 80MPa 3성분계 고강도내화콘크리트의 현장적용 및 성과분석)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.113-119
    • /
    • 2010
  • Fire resistance and field tests for high-strength concrete(HSC) of 80MPa were carried out to evaluate whether or not it shows the same material properties even in the field condition of being mass-produced and supplied. As a result, it was found that fire resistant HSCs containing composite fiber(NY, PP) of 0.075% have great resistance to fire and spalling. In the field test, before the pumping air contents, slump flow, U-box, L-flow, compressive strength, gap of hydration temperature of interior and exterior of specimen and placing ratio per hour satisfied the required properties of HSC. However, after the pumping of HSC, as slump flow and L-flow were slightly less than required criterion, they need to be improved. In terms of hydration temperature of HSC, it was found to satisfy the related criterion. Packing ability as well as placing ratio per hour of HSC, which was about $44m^3$, show outstanding results. If slump flow of developed ternary HSC is improved after the pumping it can be useful for the construction of high-rise buildings.

A Development of Pre and Post Processor for Design of Surface System of Free Form Building (비정형 건축물의 외피시스템 설계를 위한 전·후처리 모듈 개발)

  • Park, Se-Hee;Jung, Sung-Jin;Lee, Jae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.333-340
    • /
    • 2018
  • Recently, free-form buildings have been designed with complex shapes due to digitization of the construction industry. Exterior and interior components of free-form buildings have free cross sections and curved shapes. Therefore, structural members with curvature are frequently seen. In the modeling and stability evaluation of these structures, commercial programs using classical finite element analysis are not able to perform rapid shape modeling, resulting in a decrease in productivity. Therefore, in this study, pre- and post-processing modules were developed using a prior study to rapidly model the surface of a free-form building and to automatically generate frame structures that make up the cladding. The developed modules use a subdivision algorithm with spline curves. This algorithm is used to automatically generate analytical elements from the configuration information of NURBS curves. In addition, the deformation after analysis can be viewed more realistically. The modules can quickly construct complex curved surfaces. An analysis model of the frame structure was also automatically generated. Therefore, the modules could contribute to the productivity improvement of free-form building design.

Evaluation of Seismic Behavior for RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 지진거동 평가)

  • Ko, Hyun;Kim, Hyun-Su;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.13-22
    • /
    • 2010
  • Masonry infill walls are frequently used as interior partitions and exterior walls in low- or middle- rise RC buildings. In the design and assessment of buildings, the infill walls are usually treated as non-structural elements and they are ignored in analytical models because they are assumed to be beneficial to the structural responses. Therefore, their influences on the structural response are ignored. In the case of buildings constructed in the USA in highly seismic regions, infill walls have a lower strength and stiffness than the boundary frames or they are separated from the boundary frames. Thus, the previously mentioned assumptions may be reasonable. However, these systems are not usually employed in most other countries. Therefore, the differences in the seismic behaviors of RC buildings with/without masonry infill walls, which are ignored in structural design, need to be investigated. In this study, structural analyses were performed for a masonry infilled low-rise RC moment-resisting frame. The infill walls were modeled as equivalent diagonal struts. The seismic behaviors of the RC moment-resisting frame with/without masonry infill walls were evaluated. From the analytical results, masonry infill walls can increase the global strength and stiffness of a structure. Consequently, the interstory drift ratio will decrease but seismic forces applied to the structure will increase more than the design seismic load because the natural period of the structure decreases. Partial damage of the infill walls by the floor causes vertical irregularity of the strength and stiffness.

A Study of Carry Over Contamination in Chematology (이월오염에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Lyu, Jae-Gi;Jung, Dong-Jin;Kim, Gi-You;Park, Yong-Won;Chu, Kyung-Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

Accuracy Assessment on the Stereoscope based Digital Mapping Using Unmanned Aircraft Vehicle Image (무인항공기 영상을 이용한 입체시기반 수치도화 정확도 평가)

  • Yun, Kong-Hyun;Kim, Deok-In;Song, Yeong Sun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.1
    • /
    • pp.111-121
    • /
    • 2018
  • RIn this research, digital elevation models, true-ortho image and 3-dimensional digital complied data was generated and evaluated using unmanned aircraft vehicle stereoscopic images by applying photogrammetric principles. In order to implement stereoscopic vision, digital Photogrammetric Workstation should be used necessarily. For conducting this, in this study GEOMAPPER 1.0 is used. That was developed by the Ministry of Trade, Industry and Energy. To realize stereoscopic vision using two overlapping images of the unmanned aerial vehicle, the interior and exterior orientation parameters should be calculated. Especially lens distortion of non-metric camera must be accurately compensated for stereoscope. In this work. photogrammetric orientation process was conducted using commercial Software, PhotoScan 1.4. Fixed wing KRobotics KD-2 was used for the acquisition of UAV images. True-ortho photo was generated and digital topographic map was partially produced. Finally, we presented error analysis on the generated digital complied map. As the results, it is confirmed that the production of digital terrain map with a scale 1:2,500~1:3,000 is available using stereoscope method.