• Title/Summary/Keyword: extended field radiation therapy

Search Result 20, Processing Time 0.028 seconds

Treatment outcomes of extended-field radiation therapy for thoracic superficial esophageal cancer

  • Lee, Doo Yeul;Moon, Sung Ho;Cho, Kwan Ho;Kim, Tae Hyun;Kim, Moon Soo;Lee, Jong Yeul;Suh, Yang-Gun
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.241-248
    • /
    • 2017
  • Purpose: To evaluate the efficacy and safety of extended-field radiation therapy for patients with thoracic superficial esophageal cancer (SEC). Materials and Methods: From May 2007 to October 2016, a total of 24 patients with thoracic SEC (T1a and T1b) who underwent definitive radiotherapy and were analyzed retrospectively. The median total radiotherapy dose was 64 Gy (range, 54 to 66 Gy) in conventional fractionation. All 24 patients received radiotherapy to whole thoracic esophagus and 23 patients received elective nodal irradiation. The supraclavicular lymph nodes, the celiac lymph nodes, and both of those nodal areas were included in 11, 3, and 9 patients, respectively. Results: The median follow-up duration was 28.7 months (range 7.9 to 108.0 months). The 3-year overall survival, local control, and progression-free survival rates were 95.2%, 89.7%, and 78.7%, respectively. There were 5 patients (20.8%) with progression of disease, 2 local failures (8.3%) and 3 (12.5%) regional failures. Three patients also experienced distant metastasis and had died of disease progression. There were no treatment-related toxicities of grade 3 or higher. Conclusion: Definitive extended-field radiotherapy for thoracic SEC showed durable disease control rates in medically inoperable and endoscopically unfit patients. Even extended-field radiotherapy with elective nodal irradiation was safe without grade 3 or 4 toxicities.

Importance of PET/CT Scan Use in Planning Radiation Therapy for Lymphoma

  • Milana, Mitric-Askovic;Marko, Erak;Miroslav, Latinovic;Tihomir, Dugandzija
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.2051-2054
    • /
    • 2015
  • Background: Radiation therapy is a key part of the combined modality treatment for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), which can achieve locoregional control of disease. The 3D-conformal radiation oncology can be extended-field (EFRT), involved-field (IFRT) and involved node (INRT). New techniques have resulted in a smaller radiation field and lower dose for critical organs such as lung heart and breast. Materials and Methods: In our research, we made a virtual simulation for one patient who was treated in four different radiotherapeutic techniques: mantle field (MFRT), EFRT, IFRT and INRT. After delineatiion we compared dose-volume histograms for each technique. The fusion of CT for planning radiotherapy with the initial PET/CT was made using Softver Xio 4.6 in the Focal program. The dose for all four techniques was 36Gy. Results: Our results support the use of PET/CT in radiation therapy planning. With IFRT and INRT, the burden on the organs at risk is less than with MFRT and EFRT. On the other hand, the dose distribution in the target volume is much better with the latter. Conclusions: The aim of modern radiotherapy of HL and NHL is to reduce the intensity of treatment and therefore PET/CT should be used to reduce and not increase the amount of tissue receiving radiation.

Study on Physical Penumbra of Radiation Therapy (방사선치료시 물리학적 반음영의 검토)

  • Kim, Young-Bum;Whang, Woong-Ku;Kim, You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.84-88
    • /
    • 1994
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing enery level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Study on Physical Penumbra of Radiation Therapy (방사선치료시 물리학적 반음영의 검토)

  • Kim, Young-Bum;Whang, Woong-Ku;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 1993
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing energy level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

'THE METHOD OF TBI FOR ACCURATE REPRODUCTION OF RADIATION FIELD AND PATIENT POSITION' (방사선 전신 조사 치료시 정확한 환자자세 및 조사야 재현을 위한 방법)

  • KWEON YOUNG-HO;LEE BYOUNG-GOO;WHANG WOONG-KU;KIM YOU-HYUN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.156-166
    • /
    • 1995
  • Total body irradiation (TBI) requires large radiation field and extended source to axis distance (SAD), therefore in needs large size treatment room and it needs compensators which components. Appropriate thickness beam spoiler should be used to raise skin dose. Treatment machine, photon energy, total dose, dose rate, dose fractionation, patient position, shield of normal tissues and organs were known to important parameters for TBI. TBI disturbes regular daily treatment schedule and significantly overloads Radiation on oncology departments and during the treatment session it requires accurate reproduction of radiation field and patient position. We were enable to TBI in small size treatment room and short SAD with parallel opposing lateral fields technique and achieved homogenious whole body dose distribution using pb compensators and controled lung dose by lung shield blocks. Drawing a patient shadow on the wall, we could shortened set up time and possible to accurate reproduction of radiation field and patient position.

  • PDF

Studies on Dose Distribution and Treatment Technique of High Energy Electron (고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究))

  • Lee, D.H.;Chu, S.S.
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Analysis of Radiation Field and Block Pattern for Optimal Size in Multileaf Collimator (치료조사면 및 블록 유형분석을 통한 적정 다엽 콜리메이터 규모에 관한 연구)

  • Ahn, Seoung-Do;Yang, Kwang-Mo;Yi, Byong-Yong;Choi, Eun-Kyong;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.253-262
    • /
    • 1994
  • The patterns of the conventional radiation treatment fields and their shielding blocks are analysed to determine the optimal dimension of the MultiLeaf Collimator (MLC) which is considered as an essential tool for conformal therapy. Total 1109 radiation fields from 303 patients (203 from Asan Medical center, 50 from Baek Hosp and 50 from Hanyang Univ. Hosp.) were analysed for this study. Weighted case selection treatment site (from The Korean Society of Therapeutic Radiology 1993). Ninety one percent of total fields have shielding blocks. Y axis is defined as leaf movement direction and it is assumed that MLC is installed on the cranial-caudal direction. The length of X axis were distributed from 4cm to 40cm (less than 21cm for $95\%$ of cases), and Y axis from 5cm to 38cm (less than 22cm for $95\%$ of cases). The shielding blocks extended to less than 6cm from center of the field for $95\%$ of the cases. Start length for ninety five percent of block is less than 10cm for X axis and 11cm for Y axis. Seventy six percent of shielding blocks could be placed by either X or Y axis direction, $7.9\%$ only by Y axis, $5.1\%$ only by X axis and It is reasonable to install MLC for Y direction. Ninety five percent of patients can be treated with coplanar rotation therapy without changing the collimator angle. Eleven percent of cases of cases were impossible to replace with MLC. Futher study of shielding technique is needed for $11\%$ impossible cases. The treatment field dimension of MLC should be larger than $21cm{\times}22cm$. The MLC should be designed as a pair of 21 leaves with 1cm wide for an acceptable resolution and 17cm long to enable the leaf to overtravel at least 6cm from the treatment field center.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF