• Title/Summary/Keyword: exposure time and temperature

Search Result 501, Processing Time 0.035 seconds

High Hydrostatic Pressure Sterilization of Vibrio parahaemolyticus and Escherichia coli in Raw Oyster (생굴 중 Vibrio parahaemolyticus와 Escherichia coli의 초고압 살균)

  • Park, Whan-Jun;Jwa, Mi-Kyung;Hyun, Sun-Hee;Lim, Sang-Bin;Song, Dae-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.7
    • /
    • pp.935-939
    • /
    • 2006
  • Raw oyster (Crassostrea gigas) was inoculated with Vibrio parahaemolyticus and Escherichia coli, treated with high hydrostatic pressure and evaluated for microbial counts. Cell death of V. parahaemolyticus (Vp) increased with the increase of applied pressure. Vp starting inoculum of $3.8{\times}10^5\;CFU/mL$ was totally eliminated after exposure to 200 MPa for 10 min at $22^{\circ}C$ Viable cell of Vp decreased with the increase in treatment time and dropped below the detection limit with treament of 25 min at $22^{\circ}C/150\;MPa$. The number of Vp by treatment of $0^{\circ}C$ and $10^{\circ}C$ for 20 and 25 mon at 100 MPa, respectively. For E. coli, there was an initial lag up to 250 MPa gollowed by a rapid decline. Treatment at 325 MPa/$22^{\circ}C$ for 15 min caused 5-log reduction, while that at 375 MPa resulted in total reduction of starting inoculum of $4.0{\times}10^7\;CFU/mL$. Lower treatment temperature showed higher killing effect of E. coli at the same treatment pressure and time. Viable cell of E. coli decreased with the increase in treatment time, and 4-log reduction was achieved with treatment of 5 min at $10^{\circ}C$/350 MPa and then total reduction was achieved after treatment of 15 mon. Higher pressure, lower temperature and longer time were more effective in sterilizing V. parahaemolyticus and E. coli.

Effects of Increasing Moisture Content with or without Supplementing Inoculant (Lactobacillus plantarum) in TMR on Its Feed Value (TMR 제조 시 수분 함량 및 발효제 (Lactobacillus plantarum) 첨가유무가 사료가치에 미치는 영향)

  • Ki, Kwang-Seok;Kim, Hyeon-Shup;Lee, Hyun-June;Lee, Wang-Shik;Baek, Kwang-Soo;Kim, Sang-Bum;Lim, Keun-Bal;Jeo, Joon-Mo;Kim, Yong-Kook
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.27 no.3
    • /
    • pp.197-208
    • /
    • 2007
  • This study was carried out to investigate effects of increasing moisture content with or without supplementing inoculant (Lactobacillus plantarum) in TMR (total mixed ration) on its feed value. In case of exposing TMR to air, the lower the moisture level of TMR was, the less its apparent condition was changed. The time of spreading of molds tended to be faster in TMR with the higher moisture level. And also the odor was influenced by moisture content and inoculant supplement that is, sour odor was smelled from 24 hour after exposing TMR containing 35% and 50% moisture to air, but TMR supplemented with inoculant had sweet odor. The inner temperature of TMR containing 35% and 50% moisture without inoculant tended to increase continually after the lapse of 6 hours when the TMR was exposed to air. The inner temperature of TMR containing 35% moisture with inoculant tended to increase dramatically after the lapse of 48 hours when exposed to air, but that of TMR containing 50% moisture with inoculant tended to increase after 6 hours. The pH of TMR containing 15% was consistent regardless of exposing time to air, but that of TMR containing 35% and 50% moisture considerably increased after 12 and 24 hours, respectively. The concentration of $NH_3-N$ of TMR supplemented with inoculant was increased from 6 hours after exposure to air, while that or TMR without inoculant increased from 12 hours. Nutrient content or TMR tended to be increased with the increase of exposing time to air and storage time under sealed condition.

Evaluation of the Thermal Degradation in Co-based Superalloy using High frequency Transducer of Scanning Acoustic Microscope (초음파현미경의 고주파 초음파 탐촉자를 이용한 코발트기 초내열합금강의 열화평가)

  • Park, Ik-Keun;Cho, Dong-Su;Kim, Yong-Kwon;Lim, Jae-Seang;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.518-524
    • /
    • 2004
  • The feasibility of Y(z) curve method of scanning acoustic microscope using high frequency transducer was experimentally studied for assessment of the thermal degradation in Co-based superalloy. Thermal degradation was performed to simulate the microstructural changes in Co-based superalloy arising from long term exposure at high temperature. Longitudinal wave velocity measured by pulse echo method using 10MHz transducer and leaky surface acoustic wave (LSAW) velocity measured by V(z) curve method using 200MHE transducer were measured to investigate the effect on thermal degradation. Ultrasonic velocity decreased as the aging time increased in both ultrasonic waves. Moreover, the low frequency longitudinal wave velocity decreased a little. Otherwise, the high frequency LSAW velocity drastically decreased up to a maximum of 4.7% at the aging time of 4,000hours. A good correlation was found between LSAW and Vickers hardness. Consequently, V(z) curve method of SAM using high frequency transducer could be a potential tool for assessing thermal degradation.

Physiological Changes of Saccharomyces cerevisiae KNU5377 Occurred in the Process of the 48-hour Ethanol Fermentation at 40℃ (40℃ 48시간 에탄올발효 과정 중 일어나는 Saccharomyces cerevisiae KNU5377의 생리 변화)

  • Kwak, Sun-Hye;Kim, Il-Sup;Kang, Kyung-Hee;Lee, Jung-Sook;Jin, Ingn-Yol
    • Journal of Life Science
    • /
    • v.21 no.1
    • /
    • pp.146-154
    • /
    • 2011
  • In this study, physiological changes in a thermotolerant yeast Saccharomyces cerevisiae KNU5377 cell exposed to 48-hour alcohol fermentation at $40^{\circ}C$ were investigated. After 12 hours of alcohol fermentation at $40^{\circ}C$, the $C_{16:1}$ unsaturated acid of plasma membrane increased to 1.5 times more than the $C_{16:0}$ saturated fatty acid, and to about 2 times more for the $C_{18:1}$ unsaturated fatty acid. Fermentation at both $30^{\circ}C$ and $37^{\circ}C$ fermentation showed the same pattern as that done at $40^{\circ}C$. The pH of the alcohol-fermentation medium was reduced to pH 4.1 from a starting pH of 6.0 through the 12-hr fermentation and then maintained this level during the continuing fermentation. With the process of fermentation, the remaining glucose was reduced, but its amount remaining during the $40^{\circ}C$-fermentation was less reduced than those fermented at $30^{\circ}C$ and $37^{\circ}C$. In the study investigating the changing pattern of cellular proteins in the alcohol-fermenting cells, the SDS-PAGE and 2-D data indicated the most expressed dot was phosphoglycerate kinase, which is one enzyme involved in glycolysis. Why this enzyme was most expressed in the cells exposed to unfavorable conditions such as high temperature, increasing concentration of produced alcohol and long time exposure to other stress factors remains unsolved.

A study on the status of asbestos use on ships (선박에서의 석면 사용실태 연구)

  • Park, Seung-Hyun;Chung, Eun-Kyo;Kwon, Ji-Woon;Kim, Kab-Bae;Chung, Kwang-Jae;Yi, Gwang-Yong;Shin, Jung-Ah;Lee, In-Seop;Kang, Seong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.123-127
    • /
    • 2011
  • Objectives: The purpose of this study was to investigate the status of asbestos-containing materials (ACMs) used on ships and to consider measures for preventing worker exposure to asbestos fibers. Methods: A total of 17 ships including 16 ships under repair and a ship under construction at shipyards in Korea were investigated. Bulk samples were collected from suspected ACMs on engine exhaust pipes, boiler steam pipes, generator exhaust pipes, and etc. in ships in order to identify the presence of ACMs. Types and contents of asbestos were determined using polarized light microscopy (PLM). Results: ACMs were found from 14 ships out of 17 ships investigated. Only chrysotile asbestos was found from all samples. ACMs were mainly found from samples collected at the exhaust pipes of the engine, generator and incinerator, and boiler steam pipes where exhaust gases or steam of high temperature pass through. In most cases, types of ACMs were asbestos-containing fabrics such as asbestos tape. Friable ACMs were also found in some cases. Use of ACMs on ships was relevant to built time and owner of the ships rather than type and tonnage of the ships. Conclusions: ACMs were found from most ships built prior to 2000s. Therefore, measures for preventing asbestos-related diseases such as preparation of asbestos map on the ship and installation of warning signs, hazard communication with workers (ship-repairing workers, engine room workers and etc.), and follow-up for worker's health management are needed.

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

Thermal and UV Resistance of Polytrimethylene Terephthalate Bulked Continuous Filament (PTT BCF) dyed with Vat Dye via Pad-steam Method and its Dyeing Properties (Pad-steam 법을 활용한 PTT BCF에 대한 vat 염료의 염색 특성과 내열성 및 내광성 효과)

  • Lee, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.23-32
    • /
    • 2020
  • This study investigated the thermal degradation and fading behavior of PTT dyed with vat dye and its dyeing ability. The PTT sample was dyed with vat dye using an acid treatment and pad-steam method to improve the dyeing performance. This method made dye particle nanosize and allowed it to penetrate the polymer material easily. The sample dyed using the pad-steam method showed level dyeing and enhanced dyeing affinity, compared to the batch-dyeing method. The degradation behavior of PTT dyed with vat dye after each heat and UV treatment was examined with the change in tensile strength or K/S value on the sample. The tensile strength and K/S values of the sample dyed with vat dye after the heat and UV treatment decreased with increasing temperature and exposure time. Although they showed high degradation under severe conditions, its rate constant was improved compared to the samples dyed with disperse dye. Consequently, acid treatment and the pad-steam method resulted in the introduction of vat dye on PTT. In addition, the PTT dyed with vat dye showed enhanced thermal and UV resistance because of their high molecular weight and chemical structure for stable adsorption behavior.

Optimization of Wool Dyeing with Yellow Dye from Carthamus Tinctorius L. (홍화 황색소를 이용한 모염색의 최적화)

  • Shin, Youn-Sook;Son, Kyung-Hee;Yoo, Dong-Il
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.12
    • /
    • pp.1971-1978
    • /
    • 2009
  • This study investigated the adsorption of safflower yellow dye on wool protein fiber and the optimum dyeing conditions to test color reproducibility. In addition, the effects of mordants on dye adsorption, color, fastness, and photofading rate were also studied. The prepared dye in powder form was characterized with UV-vis spectroscopy and FT-IR spectrometric analysis. The color of dyed fabrics was characterized by CIE $L^*a^*b^*$ coordinates, H V/C, and K/S values. The color reproducibility of the dyed wool fabrics was examined. The amount of dye adsorption increased and also, the shade of the dyed wool fabrics became deeper and more saturated with increasing temperature, time, and dye concentration. The maximum color strength was obtained at pH 3.0. The shade of dyed wool fabrics ranged from light yellow to dark mustard yellow as the pH of the dye bath shifted from alkaline to acidic. Color reproducibility was reliable with color differences in the range of 0.53~1.75. Fastness to dry cleaning was relatively good at 4/5 rating irrespective of mordanting. Fe and Cu mordants showed the least color change of the dyed wool fabrics after exposure to light. Mordants did not contribute to improve dye uptake and color fastness, although they made variations in color tone. Safflower yellow dye can be used satisfactorily without mordants and will not cause damage to the environment.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials (건축용 바닥재로부터의 휘발성유기화합물 방출특성)

  • Yun, Joong-Seop;Lee, Myong-Hwa;Eom, Seok-Won;Kim, Min-Young;Kim, Jong-Ho;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.973-978
    • /
    • 2010
  • The emission of volatile organic compounds (VOCs) from building materials is one of great concerns due to maintain airtight condition of a building to reduce energy consumption, and it causes the deterioration of indoor air quality. Therefore, the emission characterization of VOCs from building materials is necessary to improve indoor air quality. Emission characteristics of VOCs from a plywood flooring that is one of the most commonly used materials in an under-heating system, and from an adhesive that is generally used to stick a plywood flooring to a concrete floor were investigated using an emission chamber test in this study. It was found that the VOCs emission factor was dependent upon and proportional to indoor temperature, and the emission characteristics were closely related to the existing places and conditions of VOCs sources inside the building materials. Maximum emission factors of hexane and toluene from building materials were generally observed at the beginning, however, only that of toluene from a plywood flooring was shown after 6 hours from the beginning. It could be considered that the existing place and condition of toluene source inside a plywood flooring could influence on the VOCs emission. From this study, bake-out time more than 72 hours could be recommended before moving in to avoid the exposure to high concentration of VOCs emitted from an under-heating system.