• Title/Summary/Keyword: exposure sources

Search Result 405, Processing Time 0.029 seconds

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

A meta-analysis of exposure to particulate matter and adverse birth outcomes

  • Lamichhane, Dirga Kumar;Leem, Jong-Han;Lee, Ji-Young;Kim, Hwan-Cheol
    • Environmental Analysis Health and Toxicology
    • /
    • v.30
    • /
    • pp.11.1-11.19
    • /
    • 2015
  • Objectives The objective of this study was to conduct a systematic review to provide summarized evidence on the association between maternal exposure to particulate air pollution and birth weight (BW) and preterm birth (PTB) after taking into consideration the potential confounding effect of maternal smoking. Methods We systematically searched all published cohort and case-control studies examining BW and PTB association with particulate matter (PM, less than or equal to $2.5{\mu}m$ and $10.0{\mu}m$ in diameter, $PM_{2.5}$ and $PM_{10}$, respectively) from PubMed and Web of Science, from January 1980 to April 2015. We extracted coefficients for continuous BW and odds ratio (OR) for PTB from each individual study, and meta-analysis was used to combine the coefficient and OR of individual studies. The methodological quality of individual study was assessed using a standard protocol proposed by Downs and Black. Forty-four studies met the inclusion criteria. Results In random effects meta-analyses, BW as a continuous outcome was negatively associated with $10{\mu}g/m^3$ increase in $PM_{10}$ (-10.31 g; 95% confidence interval [CI], -13.57 to -3.13 g; I-squared=0%, p=0.947) and $PM_{2.5}$ (-22.17 g; 95% CI, -37.93 to -6.41 g; Isquared=92.3%, p<0.001) exposure during entire pregnancy, adjusted for maternal smoking. A significantly increased risk of PTB per $10{\mu}g/m^3$ increase in $PM_{10}$ (OR, 1.23; 95% CI, 1.04 to 1.41; I-squared=0%, p=0.977) and $PM_{2.5}$ (OR, 1.14; 95% CI, 1.06 to 1.22; I-squared=92.5%, p<0.001) exposure during entire pregnancy was observed. Effect size of change in BW per $10{\mu}g/m^3$ increase in PM tended to report stronger associations after adjustment for maternal smoking. Conclusions While this systematic review supports an adverse impact of maternal exposure to particulate air pollution on birth outcomes, variation in effects by exposure period and sources of heterogeneity between studies should be further explored.

A Study on the Environmental Radiation Dose Measurement in the Nuclear Medicine Department (핵의학과에서 환경방사선량 측정에 대한 연구)

  • Kang, Bo-Sun;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2118-2123
    • /
    • 2010
  • Korean individual occupational exposure control is focused on the retrospective service to the over-exposed person by the reading of personal dosimeter. Since the radiophamaceuticals using in the nuclear medicine department are uncontained radiation sources, the potential exposure at working environment is very high. Moreover, a patient remains radioactive for hours or even days after the administration of a radiopharmaceutical for diagnosis or treatment. Thus, the proper working environmental exposure control must be established and executed to protect not only the affiliated employees, but also guardians accompanying patients and temporarily visiting public from the exposure by the patients. Japanese radiation protection law regulates working environmental radiation exposure by regularly measuring and filing the environmental dose for years. This study was aimed at measuring working environmental radiation dose in the nuclear medicine department of an university hospital located in Daejeon, Korea. We measured the accumulation radiation dose in air at 8 locations in the nuclear medicine department by using the same method as in Japan with glass dosimeters. The highest dose rate, 0.23 mSv per month, was measured at the waiting room, and the second one is at reception desk. Even though the doses were lower than the Korean constraint dose rate (0.3 mSv/week) at the boundary of the radiation controlled area, it was over the dose limit of public (1 mSv/y) and environment (0.25 mSv/y). Conclusionally, it was found that the new or additional procedure was necessary to less the exposure dose to the receptionist and guardians by the environmental radiation dose in the nuclear medicine department.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

Enhanced Production of Astaxanthin in Paracoccus haeundaensis Strain by Physical and Chemical Mutagenesis (물리·화학적 돌연변이 유도를 통한 Paracoccus haeundaensis의 astaxanthin 생산량 증대)

  • Seo, Yong Bae;Jeong, Tae Hyug;Choi, Seong Seok;Lim, Han Kyu;Kim, Gun-Do
    • Journal of Life Science
    • /
    • v.27 no.3
    • /
    • pp.339-345
    • /
    • 2017
  • Carotenoids are natural lipid-soluble pigments, which are produced primarily by bacteria, algae, and plants. Many studies have focused on the identification, production, and utilization of natural sources of astaxanthin from algae, yeast, and crustacean byproducts as an alternative to the synthetic pigment, which is mostly used today. The aim of the present study was to identify a mutant of Paracoccus haeundaensis by exposure to UV and ethyl methanesulfonate (EMS). The mutant was then exposed to nutrient stress conditions to isolate an astaxanthin-hyperproducing strain, followed by characterization of the mutant. The survival rate decreased in accordance with an increase in the UV exposure time and an increase in the EMS concentration. A mutant of the original P. haeundaensis strain was identified that showed hyperproduction of astaxanthin following exposure to UV irradiation (20 min) and EMS treatment (0.4 M concentration). The optimal culture conditions for the PUE mutant were $25^{\circ}C$, pH 7-8, and 3% NaCl. The effects of various carbon and nitrogen sources on the growth and astaxanthin production of PUE were examined. The addition of 1% raffinose and 3% potassium nitrate influenced cell growth and astaxanthin production. The selected mutant exhibited an increase of 1.58 folds in astaxanthin content compared to initial wild type strain. A genetically stable mutant strain obtained using mutagen (UV irradiation and EMS treatment) may be a suitable candidate for further industrial scale production of astaxanthin.

Congener Specific Profiles and Exposure Pathways of Polybrominated Diphenyl Ethers (PBDEs) in Breast Milk of Chuncheon Area (춘천지역 모유 중 폴리브롬화디페닐메테르(PBDEs)의 이성체별 분포특성과 노출경로)

  • We, Sung-Ug;Baek, In-Cheon;Park, Sang-Ah;Kang, Seong-Hoon;Cho, Yu-Jin;Cho, Bong-Hui;Yoon, Cho-Hee;Kim, Ki-Ho;Min, Byung-Yoon
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.356-364
    • /
    • 2010
  • This study was carried out to investigate the exposure pathway of PBDEs in human breast milk collected from new mothers residing in Chuncheon, a comparatively clean area in Korea. The congeners of PBDE in 22 human breast milk samples were analyzed using a high resolution gas chromatography with a high resolution mass detector. The residue level of ${\sum}PBDEs$ was higher in primipara subjects than in multipara subjects (p<0.05). The levels in this study were similar to those of people in some Asian and European countries, but were lower than those of people in north America. In the congener profiles, BDE-47 (mean contribution=36.1%) was predominant, followed by BDE-153 (27%), BDE-99 (11.7%), BDE-100 (11.1%), BDE-28 (7.9%) and BDE-183 (3.5%). The sum of BDE-47 and BDE-153 accounted for more than 50% of ${\sum}PBDEs$ in most samples. BDE-47 was highly correlated with ${\sum}PBDEs$ (r=0.94, p<0.001). No strong trend was observed between PBDE levels and a number of key biological factors (women's age, weight, height and body mass index) examined in this study, however, weak correlations were observed in PBDE levels measured against dietary habits, particularly in fish consumption frequency. It seems that Korean people might be exposed to multiple sources including products of PBDEs, and particularly food resources.

An Improvement of the Control Characteristics of Induction Motors using Adaptive Flux Observers (적응자속 업저버를 이용한 유도전동기의 제어특성 개선에 관한 연구)

  • 윤병도;박현호;김찬기
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.46-54
    • /
    • 1994
  • Exhbitlon hghting design be done aftrr due consideration of the photochermcal reaction and h ~ ~ i i tc~.fficits~ upn exposure to light. In this study the balanced judgement is as follows. The most light-susceptible material shouid be illu~stratrui less than 50[k] (illurnlnance-hours per year : 120, 000k.h)and the illuminance of moderately sensitive rriatcrinl k 200[1x] (illuminance hours per year : 480, 0001x.h). Moreover to minimize damage the sources of light shoulcl not only contribute as little as heat possible but remove ultraviolt radiation by filters. Also the sources of light must have good color rendering and low color temperature.

  • PDF

Light Modeling with Radiance Map (라디안스 맵을 이용한 광원 모델잉)

  • Kim, Mo-Geun;Kim, Seong-Jin;Jeong, Sun-Gi
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.10
    • /
    • pp.491-498
    • /
    • 2001
  • We present a method of modeling lights from photographs taken with conventional imaging equipment. It does not use both any geometrical information and special apparatus to calculate surface reflection properties. To represent surface reflection properties of the scene, we use BRDFs which are calculated by radiance values of surface elements and light sources. And the BRDF data of each surface is further transformed to the spherical harmonic domain for efficient storage. Thus it allows to reconstruct the photo-realistic scene under different light sources, to manipulate diversely the arbitrary light source and to control exposure time of camera sensor. Moreover we test our algorithm with real image instead of synthetic image.

  • PDF

BASIS RESEARCH ON NOISE CONTROL OF HEAD-FEEDING TYPE COMBINE HARVESTER USING SOUND INTENSITY METHOD

  • Sasao, A.;Iwasa, M.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.752-760
    • /
    • 1993
  • We research ed on the noise control of a head feeding type combine harvester. It is a kind of combine harvester developed in Japan. And at present, it is used by most Japanese farmer. For a head-feeding type combine harvester it is very difficult to determine the sources of noise because it is a combination of reapers and automatic , threshers and several running parts. However we succeeded in finding out the sound sources of combine harvesters and analyzing their sound by the using sound intensity method. The sound intensity Method is a very up-to-date method to measure and analyze Sound Intensity Levels and sound directions at several measuring point sin a specified area. In this research, first a conventional sound level measurement method is used and secondly the sound intensity method. The first method shows a rather great limitation in allowed exposure duration. The second method shows pin-points the engine itself as being the main source of noise, causing sound flows a ross the operator's seat.

  • PDF