• Title/Summary/Keyword: exposure model evaluation

Search Result 169, Processing Time 0.03 seconds

Development of a Risk Analysis Assessment Models for the Construction Projects (건설공사의 위험도 분석평가 및 모델개발)

  • Lee, Jeong-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.233-240
    • /
    • 1999
  • Even though the recent construction safety disasters not only result in the loss inside construction sites but also become to a large public disasters, safety activities are managed in an irrational way and safety rules are ignored in the construction sites which leads to occur same type of disasters repeatedly. In this paper, a fuzzy set theoretic approach to risk analysis is proposed as an alternative to the techniques currently used in the general construction projects safety. Then the concept of risk evaluation using linguistic representation of the likelihood, exposure and consequences is introduced. A risk assessment model using approximate reasoning technique base on fuzzy logic is presented to drive fuzzy values of risk and numerical example for risk analysis is also presented to illustrate the results.

  • PDF

A sensitivity analysis of machine learning models on fire-induced spalling of concrete: Revealing the impact of data manipulation on accuracy and explainability

  • Mohammad K. al-Bashiti;M.Z. Naser
    • Computers and Concrete
    • /
    • v.33 no.4
    • /
    • pp.409-423
    • /
    • 2024
  • Using an extensive database, a sensitivity analysis across fifteen machine learning (ML) classifiers was conducted to evaluate the impact of various data manipulation techniques, evaluation metrics, and explainability tools. The results of this sensitivity analysis reveal that the examined models can achieve an accuracy ranging from 72-93% in predicting the fire-induced spalling of concrete and denote the light gradient boosting machine, extreme gradient boosting, and random forest algorithms as the best-performing models. Among such models, the six key factors influencing spalling were maximum exposure temperature, heating rate, compressive strength of concrete, moisture content, silica fume content, and the quantity of polypropylene fiber. Our analysis also documents some conflicting results observed with the deep learning model. As such, this study highlights the necessity of selecting suitable models and carefully evaluating the presence of possible outcome biases.

A Study on Subjective Noise Evaluation of School Area on Aircraft Noise near Airport (공항주변학교의 항공기 소음의 피해의식에 관한 연구)

  • Kim, Gap-Su;Hwang, Jeong-Hun;Bae, Eun-Hye
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.51-57
    • /
    • 2010
  • In this study, damages due to the aircraft noise were examined in more than 190 elementary, middle and high schools near the airports in Korea, and the persecutory idea forecast model was established using the quantification theory type II. Via the survey of 1,012 teachers in the schools, a class interference forecast model was established, and the noise characteristics of five areas, four military/civil common-use airports and one shooting range, were examined. The following conclusions were made from the study. WECPNL values in the five military/civil common-use airports showed that all of them were Class 1 or 2 affected areas, which indicated that they had serious aircraft noise problems to be addressed. The most influential factor in the aircraft noise persecutory idea model was the distance between the airport and the school. It showed a positive relationship at a distance of less than 5 km, and a negative relationship at a distance of 10 km or more. The number and time of aircraft noise exposure as well as the types of airports and window structures had strong influences. The forecast model had a correlation ratio of 0.56, which indicates that it is highly appropriate. In the class interference factor analysis, the time and number of aircraft noise exposure were strong influential factors, and the results varied according to the service duration and sex of teachers. This model had a correlation ratio of 0.61, which indicates it is highly appropriate.

Estimated Environmental Distribution of Acetanilide Using EQC Model (EQC모델을 이용한 Acetanilide의 환경중 분포예측)

  • 박광식;권민정;최윤호;송상환;박혜연;구현주
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.3
    • /
    • pp.133-137
    • /
    • 2001
  • Acetanilide is a High Production Volume Chemical, which is produced about 2,300 tons/year in Korea as of 1998 survey. Most is used as an intermediate for synthesis of pharmaceuticals and dyes and the chemical is one of seven chemicals of which human and environmental risks are being assessed by National Institute of Environmental Research under the frame of OECD SIDS program. The chemical is water soluble (4 g/1 at 20$\^{C}$) and readily biodegradable (68.7%). Partition coefficiency (Log Pow) is 1.16 at 23$\^{C}$ so that the chemical has a low potential for bioaccumulation. The acute toxicities of algae, daphnia and fish are not high. The 72 hr-EbC50 of algae is 13.5 mg/1,48 hr-EC50 of daphnia is over 100 mg/1 and 96 hr-LC50 of Oryzias latipes is over 100mg/1. Regarding the exposure, levels in air, water, soil or sediment have not been monitored or estimated so that risk evaluation of acetanilide was not possible. In this study, distribution of the chemical among environmental media was estimated using EQC model based on the chemical-physical properties. In Level I and IIof which the chemical are hypothesized in equilibrium and no transfer through the media, more than 98% of acetanilide are estimated to be distributed in water. However, in Level Ⅲ of which non-equilibrium and intermedia transfer could be occurred, the chemical is estimated to distributed to soil as 51.8% and water as 47.8% as of total amount.

  • PDF

Development and Evaluation of an English Speaking Task Using Smartphone and Text-to-Speech (스마트폰과 음성합성을 활용한 영어 말하기 과제의 개발과 평가)

  • Moon, Dosik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.13-20
    • /
    • 2016
  • This study explores the effects of an video-recording English speaking task model on learners. The learning model, a form of mobile learning, was developed to facilitate the learners' output practice applying advantages of a smartphone and Text-to Speech. The survey results shows the positive effects of the speaking task on the domain of pronunciation, speaking, listening, writing in terms of students' confidence, as well as general English ability. The study further examines the possibilities and limitations of the speaking task in assisting Korean learners improve their speaking ability, who do not have sufficient exposure to English input or output practice due to the situational limitations where English is learned as a foreign language.

Effect of combined sodium hyaluronate and carboxymethyl cellulose on ocular surface in rat dry eye model

  • Moon, Jong-Gab;Ku, Sae-Kwang;Kwon, Young-Sam
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.155-160
    • /
    • 2016
  • This study was conducted to evaluate three different mixed formulations of sodium hyaluronate (SH) and carboxymethyl cellulose (CMC) using a low-humidity air flow-induced rat dry eye model and determine the most suitable mixture. The total thickness of the cornea, corneal epithelial thickness, corneal stroma thickness, damaged corneal epithelium percentage region, thickness of the bulbar conjunctiva epithelium, number of goblet cells, goblet cell occupation percentage region, and damaged bulbar conjunctiva epithelium percentage region were measured by histomorphological evaluation. After 5 h exposure to drying airflow, the thickness of the cornea and conjunctiva was decreased with desquamation of the corneal and conjunctiva epithelium. However, these dry eye symptoms were markedly inhibited by treatment with the reference and test formulations. More favorable effects on decreased thickness were detected in response to the CMC than the SH. However, SH had a greater protective effect against corneal and conjunctiva epithelial damage. The application of a mixture of 0.1% SH and 0.2% CMC showed more favorable effects on the corneal and conjunctival damage and the stabilization of the ocular surface than SH or CMC alone.

A Research for Assessment Fire Toxic Gas of Construction Material Using FT-IR and FED (FT-IR과 FED를 이용한 건축 재료의 연소독성평가에 관한 연구)

  • Kim, Sung-Soo;Cho, Nam-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.27-31
    • /
    • 2011
  • In this study, combustion toxicity evaluation for building interior materials and study for toxicity as using FT-IR analysis. this experiment for the calculation of toxicity index, it using a cone calorimeter model in KS F ISO/TR 9122-4 as a fire model. It is following ISO 19702 procedure for assessing fire toxic gas using FT-IR. This experiment used calculation method for toxicity index (FED) among the international standards. $LC_{50}$ is a concentration that it can cause death to 50 % of experimental animal in 30 minutes - exposure gas test. comparison with the three kinds of toxicity fire gas of construction materials using toxicity index.

Application plan for radiological exposure model using virtual reality-based radiological exercise system

  • Lee, Dewhey;Lee, Byung Il;Park, Younwon;Kim, Dohyung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.745-750
    • /
    • 2018
  • New exercise technology such as the virtual reality (VR)-based exercise system is required to meet soaring demand for target participants in exercises and to alleviate the difficulties in personnel mobilization through an alternative approach to the exercise system. In a previous study, event tree methodologies were introduced in setting up an exercise scenario of a VR-based radiological exercise system. In the scenario, the locations at which major events occur are rephrased as nodes, routes as paths, and public response actions as protective actions or contents of an exercise at individual locations. In the study, a model for estimating effective doses to the participants is proposed to evaluate the exercise system, using the effective dose rates at particular times and locations derived from a computer program. The effective dose received by a student when she/he follows a successful route is about a half of the dose received when she/he does not follow the exercise guide directions. In addition, elapsed time to finish an exercise when following a successful route is less than one-third of the time spent to finish an exercise when following the guide's directions.

Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance (물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가)

  • Yang, Won-Ho;Son, Bu-Soon;Kim, Dae-Won;Kim, Young-Hee;Byeon, Jae-Cheol;Jung, Soon-won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

Radiological Assessment of Environmental Impact of the IF-System Facility of the RAON

  • Lee, Cheol-Woo;Whang, Won Tae;Kim, Eun Han;Han, Moon Hee;Jeong, Hae Sun;Jeong, Sol;Lee, Sang-jin
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • Background: The evaluation of skyshine distribution, release of airborne radioactive nuclides, and soil activation and groundwater migration were required for radiological assessment of the impact on the environment surrounding In-Flight (IF)-system facility of the RAON (Rare isotope Accelerator complex for ON-line experiment) accelerator complex. Materials and Methods: Monte Carlo simulation by MCNPX code was used for evaluation of skyshine and activation analysis for air and soil. The concentration model was applied in the estimation of the groundwater migration of radionuclides in soil. Results and Discussion: The skyshine dose rates at 1 km from the facility were evaluated as 1.62 × 10-3 μSv·hr-1. The annual releases of 3H and 14C were calculated as 9.62 × 10-5 mg and 1.19 × 10-1 mg, respectively. The concentrations of 3H and 22Na in drinking water were estimated as 1.22 × 10-1 Bq·cm-3 and 8.25 × 10-3 Bq·cm-3, respectively. Conclusion: Radiological assessment of environmental impact on the IF-facility of RAON was performed through evaluation of skyshine dose distribution, evaluation of annual emission of long-lived radionuclides in the air and estimation of soil activation and groundwater migration of radionuclides. As a result, much lower exposure than the limit value for the public, 1 mSv·yr-1, is expected during operation of the IF-facility.