• Title/Summary/Keyword: exposure control system

Search Result 490, Processing Time 0.031 seconds

Moist and Mold Exposure is Associated With High Prevalence of Neurological Symptoms and MCS in a Finnish Hospital Workers Cohort

  • Hyvonen, Saija;Lohi, Jouni;Tuuminen, Tamara
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.173-177
    • /
    • 2020
  • Background: Indoor air dampness microbiota (DM) is a big health hazard. Sufficient evidence exists that exposure to DM causes new asthma or exacerbation, dyspnea, infections of upper airways and allergic alveolitis. Less convincing evidence has yet been published for extrapulmonary manifestations of dampness and mold hypersensitivity syndrome). Methods: We investigated the prevalence of extrapulmonary in addition to respiratory symptoms with a questionnaire in a cohort of nurses and midwives (n = 90) exposed to DM in a Helsinki Obstetric Hospital. The corresponding prevalence was compared with an unexposed cohort (n = 45). Particular interest was put on neurological symptoms and multiple chemical sensitivity. Results: The results show that respiratory symptoms were more common among participants of the study vs. control cohort, that is, 80 vs 29%, respectively (risk ratio [RR]: 2.56, p < 0.001). Symptoms of the central or peripheral nervous system were also more common in study vs. control cohort: 81 vs 11% (RR: 6.63, p < 0.001). Fatigue was reported in 77 vs. 24%, (RR: 3.05, p < 0.001) and multiple chemical sensitivity in 40 vs. 9%, (RR: 3.44, p = 0.01), the so-called "brain fog", was prevalent in 62 vs 11% (RR: 4.94, p < 0.001), arrhythmias were reported in 57 vs. 2.4% (RR: 19.75, p < 0.001) and musculoskeletal pain in 51 vs 22% (RR: 2.02, p = 0.02) among participants of the study vs. control cohort, respectively. Conclusion: The results indicate that the exposure to DM is associated with a plethora of extrapulmonary symptoms. Presented data corroborate our recent reports on the health effects of moist and mold exposure in a workplace.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Emulation of Anti-alias Filtering in Vision Based Motion Mmeasurement (비전 센서의 앨리어싱 방지 필터링 모방 기법)

  • Kim, Jung-Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.6 no.1
    • /
    • pp.18-26
    • /
    • 2011
  • This paper presents a method, Exposure Controlled Temporal Filtering (ECF), applied to visual motion tracking, that can cancel the temporal aliasing of periodic vibrations of cameras and fluctuations in illumination through the control of exposure time. We first present a theoretical analysis of the exposure induced image time integration process and how it samples sensor impingent light that is periodically fluctuating. Based on this analysis we develop a simple method to cancel high frequency vibrations that are temporally aliased onto sampled image sequences and thus to subsequent motion tracking measurements. Simulations and experiments using the 'Center of Gravity' and Normalized Cross-Correlation motion tracking methods were performed on a microscopic motion tracking system to validate the analytical predictions.

Exposure Does of X-ray Generator on Full Wave Rectification Method (전파정류 방식의 X선 발생장치에서 조사선량)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Lee, Ho-Shik;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.138-138
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. I fabricated a high tension generator of a full-wave rectification type using a LC resonant inviter. It is said that a full-wave rectifying X-ray equipment such as the fabricated system can shorten initiating period and be precision control because of stable output, compared with the X-ray equipment of a half wave rectifying type used in the usual clinical medicine. In order to evaluate the capability of the fabricated high tension generator, I performed exposure dose characteristics experiments.

  • PDF

A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom (인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

Exposure to Dithiopyr Alters Swimming Performance Parameters in Zebrafish (Dithiopyr에 노출이 zebrafish의 유영 행동에 미치는 영향)

  • Oh, Junyoung;Park, Eun-Jin;Kang, Seongeun;Lee, Seungheon
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.181-189
    • /
    • 2016
  • The aim of this study was to identify the effects of dithiopyr (DTP), a herbicide, on behavior in zebrafish. The toxicity of DTP has rarely been investigated in fish. In the present study, zebrafish were exposed to different concentrations of DTP in the range of 10-20 μM for 48 h in a test container, in order to measure the value of median lethal concentrations (LC50). Behavioral experiments were performed, including the novel tank test (NTT) and the open field test (OFT), to assess stress responses or locomotion. After exposure to the DTP solution at a sublethal concentration of 2.5–10 μM for 6 min, the behavior of the zebrafish was observed for 6 min. In the acute toxicity test, the LC50 value of DTP showed as 14.49 μM in the zebrafish. The NTT showed that the duration of immobility and the velocity were significantly increased by exposure at a concentration of 5 μM of DTP, compared with a control group (p<0.05). However, compared with the control group, DTP significantly decreased the distance moved and the frequency at the top of the tank, and significantly increased the turn angle and duration at the bottom, in a concentration-dependent manner (p<0.05). In addition, in the OFT, exposure to DTP significantly decreased the distance moved and velocity compared with the control group (p<0.05). Exposure to DTP also significantly increased the duration of immobility, the turn angle, and the meandering movement, in a concentration-dependent manner (p<0.05). Further, exposure to DTP at a low concentration elevated whole-body cortisol levels in the zebrafish. The results of this study thus suggest that DTP induces a toxic response and negative effects on behavior and the endocrine system in zebrafish.

Development of Intelligent Remote Beam Control Function in E-Beam Manufacturing System (전자빔 가공기의 지능형 원격 빔 조절 기능의 개발)

  • Lim Sun-Jong;Lyou Joon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.24-29
    • /
    • 2006
  • The use electron-beam(E-beam) manufacturing system provides a means to alleviate optic exposure equipment's problems. We are developing an E-beam manufacturing system with scanning electron microscope(SEM) function. The E-beam manufacturing system consist of high voltage generator, beam blanker, condenser lenses, object lenses, stigmator and stage. The development of E-beam manufacturing system is used on the method of remaking SEM's structure. The functions of SEM are developed. It is important for the test of E-beam performance. In E-beam manufacturing system and SEM, beam focus is important function. In this paper, we propose intelligent remote control function for beam focus in E-beam manufacturing system. The function extends the user's function and gives convenience.

Performance of steel beams strengthened with pultruded CFRP plate under various exposures

  • Gholami, M.;Sam, A.R. Mohd;Marsono, A.K.;Tahir, M.M.;Faridmehr, I.
    • Steel and Composite Structures
    • /
    • v.20 no.5
    • /
    • pp.999-1022
    • /
    • 2016
  • The use of Carbon Fiber Reinforced Polymer (CFRP) to strengthen steel structures has attracted the attention of researchers greatly. Previous studies demonstrated bonding of CFRP plates to the steel sections has been a successful method to increase the mechanical properties. However, the main limitation to popular use of steel/CFRP strengthening system is the concern on durability of bonding between steel and CFRP in various environmental conditions. The paper evaluates the performance of I-section steel beams strengthened with pultruded CFRP plate on the bottom flange after exposure to diverse conditions including natural tropical climate, wet/dry cycles, plain water, salt water and acidic solution. Four-point bending tests were performed at specific intervals and the mechanical properties were compared to the control beam. Besides, the ductility of the strengthened beams and distribution of shear stress in adhesive layer were investigated thoroughly. The study found the adhesive layer was the critical part and the performance of the system related directly to its behavior. The highest strength degradation was observed for the beams immersed in salt water around 18% after 8 months exposure. Besides, the ductility of all strengthened beams increased after exposure. A theoretical procedure was employed to model the degradation of epoxy adhesive.

Reponses of the Hepatic Microsomal Cytochrome P450 Monooxygenase System in Rock Bream Oplegnathus fasciatus Exposed to Tributyltin (TBT)

  • Hwang, Un-Gi;Lee, Jung-Sik;Kang, Ju-Chan
    • Fisheries and Aquatic Sciences
    • /
    • v.16 no.4
    • /
    • pp.261-265
    • /
    • 2013
  • The study was conducted to investigate the responses of the hepatic microsomal cytochrome P450 monooxygenase system in the rock bream Oplegnathus fasciatus after chronic exposure to 0, 1, 2, 4, and $8{\mu}g/L$ tributyltin (TBT) concentrations for 4 weeks. Hepatic cytochrome 450 content and ethoxyresorufin O-deethylation (EROD) activity were found to significantly increase in fish treated with the higher concentration of TBT (${\geq}4{\mu}g/L$); however, no significant changes were observed in penthoxyresorufin O-deethylation (PROD) activity in all treated groups compared to the control group. These findings suggest that exposure to a low TBT concentration (${\geq}4{\mu}g/L$) has the potential to induce cytochrome 450 content and EROD enzyme activity in hepatic tissue in the rock bream.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.