• 제목/요약/키워드: exposure control system

검색결과 490건 처리시간 0.038초

LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발 (Mechanical Design and Development of a Digital Tongue Imaging System Equipped with LEDs)

  • 남동현;김지혜;이상석
    • 대한한의진단학회지
    • /
    • 제16권3호
    • /
    • pp.41-48
    • /
    • 2012
  • Objectives: The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS) equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results: We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast, if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was $28.3^{\circ}$ when tongue was lightly exposed and $13.3^{\circ}$ when maximally. So we determined $73^{\circ}$ as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions: We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Design of Induction Heating Coil for Automatic Hull Forming System

  • Ryu, Hyun-su
    • 해양환경안전학회지
    • /
    • 제24권3호
    • /
    • pp.360-366
    • /
    • 2018
  • In shipyards hull forming is performed by the line heating method using a gas torch and by cold treatment using a roll-press. However, this forming process has some issues, such as difficulties in controlling and accurately estimating the amount of the heat input, as well as a harsh working environment due to exposure to loud noises and air pollution. The induction heating method, which is introduced in this paper, exhibits good control and allows for the estimation of precise heat input. Also, workers can carry out the induction heating in a comfortable working environment. In this research, the induction heating simulation, which consists of electro-magnetic, heat transfer and thermal elasto-plastic analysis, was developed and modified through induction heating experiments. Finally, the effective heating coil was designed for the automatic hull forming system based on the results of induction heating simulation. For the purposes of a future study, if an algorithm to obtain optimal working conditions is developed, automatic systems for hull forming can then be constructed.

표면 가공형 캐비티 압력센서를 이용하여 비전도성 물질용 패키지 기술에 전기적 제어방식 연구 (The Electric Control Method on the Packaging Technology for Non-Conductive Materials Using the Surface Processing Cavity Pressure Sensor)

  • 이선종;우종창
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.350-354
    • /
    • 2020
  • In this study, a pressure sensor for each displacement was fabricated based on the silicon-based pressure sensor obtained through simulation results. Wires were bonded to the pressure sensor, and a piezoresistive pressure sensor was inserted into the printed circuit board (PCB) base by directly connecting a micro-electro-mechanical system (MEMS) sensor and a readout integrated circuit (ROIC) for signal processing. In addition, to prevent exposure, a non-conductive liquid silicone was injected into the sensor and the entire ROIC using a pipette. The packaging proceeded to block from the outside. Performing such packaging, comparing simple contact with strong contact, and confirming that the measured pulse wavelength appears accurately.

교류 임피던스기법을 이용한 철근부식 측정에 관한 실험적 연구 (Electrical Impedance Spectroscopy(EIS) Measurements to Evaluate Corrosion of Steel/Concrete System)

  • 정시영;김병국;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.659-662
    • /
    • 2005
  • Electrochemical impedance spectroscopy (EIS) has been extensively used to try to evaluate the corrosion state of the steel/concrete system. This technique is attractive because, in theory, used in a wide range of frequencies, it can give detailed information about the mechanisms and kinetics of the electrochemical reactions. Impedance measurements were performed using potential control and measuring the corresponding current response. One-year-old southern exposure test. specimens were used in the current study. The effectiveness of corrosion inhibiting additives was evaluated. The corrosion current densities estimated by impedance measurements were confirmed by those determined using linear polarization techniques. The purpose of this study was to evaluate the long-term-performance potential of the corrosion inhibitors in chloride contaminated reinforce concrete.

  • PDF

CMOS 이미지 센서를 위한 실시간 전처리 프로세서의 설계 (A Design of the Real-Time Preprocessor for CMOS image sensor)

  • 정윤호;이준환;김재석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.224-227
    • /
    • 1999
  • This paper presents a design of the real-time preprocessor for CMOS image sensor suitable to the digital camera applications. CMOS image sensor offers some advantages in on-chip integration, system power reduction, and low cost. However, it has a lower-quality image than CCDs. We describe an image enhancement algorithm, which includes color interpolation, color correction, gamma correction, sharpening, and automatic exposure control, to compensate for this disadvantage, and present its efficient hardware architecture to implement on the real-time processor. The presented real-time preprocessor was designed using VHDL, and it contains about 19.2K logic gates. We also implement our system on FPGA chips in order to provide the real-time adjustment and it was successfully tested.

  • PDF

Survival of Microorganisms on Antimicrobial Filters and the Removal Efficiency of Bioaerosols in an Environmental Chamber

  • Kim, Sung Yeon;Kim, Misoon;Lee, Sunghee;Lee, JungEun;Ko, GwangPyo
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권9호
    • /
    • pp.1288-1295
    • /
    • 2012
  • Exposure to bioaerosols causes various adverse health effects including infectious and respiratory diseases, and hypersensitivity. Controlling exposure to bioaerosols is important for disease control and prevention. In this study, we evaluated the efficacies of various functional filters coated with antimicrobial chemicals in deactivating representative microorganisms on filters or as bioaerosols. Tested functional filters were coated with different chemicals that included (i) Ginkgo and sumac, (ii) Ag-apatite and guanidine phosphate, (iii) $SiO_2$, ZnO, and $Al_2O_3$, and (iv) zeolite. To evaluate the filters, we used a model ventilation system (1) to evaluate the removal efficiency of bacteria (Escherichia coli and Legionella pneumophila), bacterial spores (Bacillus subtilis spore), and viruses (MS2 bacteriophage) on various functional filters, and (2) to characterize the removal efficiency of these bioaerosols. All experiments were performed at a constant temperature of $25^{\circ}C$ and humidity of 50%. Most bacteria (excluding B. subtilis) rapidly decreased on the functional filter. Therefore, we confirmed that functional filters have antimicrobial effects. Additionally, we evaluated the removal efficiency of various bioaerosols by these filters. We used a six-jet collision nebulizer to generate microbial aerosols and introduced it into the environmental chamber. We then measured the removal efficiency of functional filters with and without a medium-efficiency filter. Most bioaerosol concentrations did not significantly decrease by the functional filter only but decreased by a combination of functional and medium-efficiency filter. In conclusion, functional filters could facilitate biological removal of various bioaerosols, but physical removal of these by functional was minimal. Proper use of chemical-coated filter materials could reduce exposure to these agents.

In vivo Genotoxicity of Silver Nanoparticles after 90-day Silver Nanoparticle Inhalation Exposure

  • Kim, Jin-Sik;Sung, Jae-Hyuck;Ji, Jun-Ho;Song, Kyung-Seuk;Lee, Ji-Hyun;Kang, Chang-Soo;Yu, Il-Je
    • Safety and Health at Work
    • /
    • 제2권1호
    • /
    • pp.34-38
    • /
    • 2011
  • Objectives: The antimicrobial activity of silver nanoparticles has resulted in their widespread use in many consumer products. Yet, despite their many advantages, it is also important to determine whether silver nanoparticles may represent a hazard to the environment and human health. Methods: Thus, to evaluate the genotoxic potential of silver nanoparticles, in vivo genotoxicity testing (OECD 474, in vivo micronuclei test) was conducted after exposing male and female Sprague-Dawley rats to silver nanoparticles by inhalation for 90 days according to OECD test guideline 413 (Subchronic Inhalation Toxicity: 90 Day Study) with a good laboratory practice system. The rats were exposed to silver nanoparticles (18 nm diameter) at concentrations of $0.7\;{\times}\;10^6$ particles/$cm^3$ (low dose), $1.4\;{\times}\;10^6$ particles/$cm^3$ (middle dose), and $2.9\;{\times}\;10^6$ particles/$cm^3$ (high dose) for 6 hr/day in an inhalation chamber for 90 days. The rats were killed 24 hr after the last administration, then the femurs were removed and the bone marrow collected and evaluated for micronucleus induction. Results: There were no statistically significant differences in the micronucleated polychromatic erythrocytes or in the ratio of polychromatic erythrocytes among the total erythrocytes after silver nanoparticle exposure when compared with the control. Conclusion: The present results suggest that exposure to silver nanoparticles by inhalation for 90 days does not induce genetic toxicity in male and female rat bone marrow in vivo.

Evaluation of Some Biochemical Parameters and Brain Oxidative Stress in Experimental Rats Exposed Chronically to Silver Nitrate and the Protective Role of Vitamin E and Selenium

  • Gueroui, Mouna;Kechrid, Zine
    • Toxicological Research
    • /
    • 제32권4호
    • /
    • pp.301-309
    • /
    • 2016
  • Due to undesirable hazardous interactions with biological systems, this investigation was undertaken to evaluate the effect of chronic exposure to silver on certain biochemical and some oxidative stress parameters with histopathological examination of brain, as well as the possible protective role of selenium and/or vitamin E as nutritional supplements. Thirty six male rats were divided into six groups of six each: the first group used as a control group. Group II given both vitamin E (400 mg/kg) of diet and selenium (Se) (1 mg/L) in their drinking water. Group III given silver as silver nitrate ($AgNO_3$) (20 mg/L). Group IV given vitamin E and $AgNO_3$. Group V given both $AgNO_3$ and selenium. Group VI given $AgNO_3$, vitamin E and Se. The animals were in the same exposure conditions for 3 months. According to the results which have been obtained; there was an increase in serum lactate dehydrogenase (LDH), lipase activities and cholesterol level, a decrease in serum total protein, calcium and alkaline phosphatase (ALP) activity in Ag-intoxicated rats. Moreover, the findings showed that $Ag^+$ ions affected antioxidant defense system by decreasing superoxide dismutase (SOD) activity and increasing vitamin E concentration with a high level of malondialdehyde (MDA) in brain tissue. The histological examination also exhibited some nervous tissue alterations including hemorrhage and cytoplasm vacuolization. However, the co-administration of selenium and/or vitamin E ameliorated the biochemical parameters and restored the histological alterations. In conclusion, this study indicated that silver could cause harmful effects in animal body and these effects can be more toxic in high concentrations or prolonged time exposure to this metal. However, selenium and vitamin E act as powerful antioxidants which may exercise adverse effect against the toxicity of this metal.

물리보안 관제시스템의 보안위협 사례를 통한 취약점 분석 및 대응방안 연구 (Problem Analysis and Countermeasures Research through Security Threat Cases of Physical Security Control Systems)

  • 고윤성;박광혁;김창수
    • 한국멀티미디어학회논문지
    • /
    • 제19권1호
    • /
    • pp.51-59
    • /
    • 2016
  • Physical security protecting people from physical threats, such as a person or vehicle, has received a great attention. However, it has many risks of hacking and other security threats because it is highly dependent on automated management systems. In addition, a representative system of physical security, a CCTV control system has a high risk of hacking, such as video interceptions or video modulation. So physical security needs urgent security measures in accordance with these threats. In this paper, we examine the case of security threats that have occurred in the past, prevent those from threatening the physical security, and analyze the security problem with the threats. Then we study the countermeasures to prevent these security threats based on the problems found in each case. Finally we study for the method to apply these countermeasures.

한국인 백내장환자의 항산화 체계에 관한 연구 (A Study on Antioxidant System in Cataract Patients)

  • 고영숙;홍영재;정혜연;김수연;이양자
    • Journal of Nutrition and Health
    • /
    • 제35권2호
    • /
    • pp.229-236
    • /
    • 2002
  • Cataracts are the leading cause of blindness worldwide and are characterized by increased opacity of the lens that significantly diminishes visual acuity. It has been suggested that increased risk of lens opacities are associated with age, exposure to sunlight, diabetes, smoking, and poor nutrition. Antioxidant nutrients have born demonstrated to protect the lens membrane and protein against damage due to oxidative stress. The purpose of this study was to investigate the antioxidant system in the blood of cataract patients. The status of the blood antioxidant system was evaluated based on the levels of antioxidant vitamins and minerals as well as glutathione peroxidase (GSH-Px) and malondialdehyde (M7A) activity in 34 patients with cataracts (17 male and 17 female) and 45 control subjects (20 male and 25 female). After adjusting for age, the results showed significantly lower levels of antioxidant vitamins such as lycopene (M : p < 0.05, F: p < 0.01), zeaxanthin (F: p < 0.01), ${\gamma}$-tocopherol (F: p < 0.01) and ascorbic arid (M: p < 0.05) in the cataract patients than in the control subjects. In contrast, the concentration of cryptoxanthin (F : p < 0.07) showed a significantly higher value in the cataract patients. The serum level of the antioxidant mineral Zn (M : p < 0.01) was found to be significantly lower in the cataract patients while the ratio of cu/zn appeared significantly higher (M : p < 0.05). Significantly higher (M : p < 0.01, F: p < 0.05) concentrations of MDA in serum was found in the cataract patients as compared to the control subjects. GSH-Px activity was significantly lower (F: p < 0.05) in 71e cataract patients. In conclusion, the antioxidant system may play an important roll in cataract creation. Further studies are needed to clarify the mechanisms underlying these findings and to establish preventive measures with an emphasis on antioxidant nutrition for cataract patients.