• Title/Summary/Keyword: exposure control system

Search Result 490, Processing Time 0.025 seconds

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

Development of a Self-Travelling Sprayer for a Greenhouse (I) - Self-travelling - (시설원예용 파이프 유도식 무인방제기 개발 (I) - 무인 주행시스템 -)

  • 김태한;장익주;강춘태
    • Journal of Biosystems Engineering
    • /
    • v.24 no.3
    • /
    • pp.209-216
    • /
    • 1999
  • A self-travelling sprayer was developed to avoid the exposure of an operator to agricultural chemicals and exhaust gas, to improve safety and to increase working efficiency during the application and transport work in the greenhouses. This system consists of self-travelling system and the control system for application and safety device. The auto-spray car is equipped with a liquid chemical tank of 80l capacity. The travelling system adopted mechanical steering system which link mechanism of front wheel is guided by guide rollers. The sprayer travels along the guiding pipe which is set on the furrow in the greenhouses. The sprayer stops automatically applying and traveling when the liquid chemical tank becomes empty or when the sprayer reach the turning point. The spray booms swings in a vertical plane. The control system of safety devices controls the automatic stop of the sprayer when there is an obstacle on the traveling path, or when the battery becomes discharged. The auto-spray car traveled smoothly and steadily along the guide pipe during traveling straightly and turning on the ground.

  • PDF

Active Window to Reduce the Exterior Noise Flowed Through the Open Window (열린 창문을 통해 유입되는 소음을 저감하는 능동소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.820-827
    • /
    • 2011
  • Recently, noise has been regarded as one of the most notorious and frequent environmental pollutions which can be often encountered not only in the living space but also in the industrial site. Studies on physiological and psychological effects of long-term noise exposure to human being have commanded the public interest on noise issues. Since environmental noises such as traffic noise and construction noise is mainly flowed through the open window, it is necessary to develop the active noise control system to reduce it inside the building. Although control speakers and microphones for the noise signal measurement in the control region are essential for the conventional active noise control methods, it is impossible to implement them in the control region in the building environment because the control region is the living quarter and they may hinder activities of the residents. Therefore, we proposed the active window system to reduce the exterior noise flowed through the open window with microphones installed outside the window and control speakers installed at the frame of the window. To confirm the performance of the proposed active window, we carried out the simulation and experiment using active window system with 8 control speakers. Simulation results showed the noticeable noise reduction effect inside the control region within the frequency range without the spatial aliasing. Experimental result showed that the total acoustic potential energy inside the room of the scale model is reduced to about 10dB within the interest of frequency range.

Development of Digital Particle Holographic System for Measurements of the Characteristics of Spray Droplets (분무 액적 특성 계측을 위한 디지털 입자 홀로그래피 시스템의 개발)

  • Yan, Yang;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.15 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • This study presents development of digital particle holographic system and its application to spray field to measure three-dimensional velocities and sizes of spray droplets. A double exposure hologram recording system with synchronization system for time control was established and digital holograms can be recorded in a short time interval. To process recorded holograms, the correlation coefficient method was used for focal plane determination of particles. To remove noises and improve the quality of holograms and reconstructed images, the Wiener filter was adopted. The two-threshold and image segmentation methods were used in binary image transformation. For particle pairing, the match probability method was adopted. The developed system was applied to spray field and three-dimensional velocities and sizes of spray droplets were measured. The measurement results of digital holographic system were compared with those made by laser instruments, PDPA(Phase Doppler Particle Analyzer), which proved the feasibility of in-line digital particle holographic system as a good measurement tool for spray droplets.

Copper Toxicity on Survival, Respiration and Organ Structure of Tegillarca granosa (Bivalvia: Arcidae) (꼬막, Tegillarca granosa의 생존, 호흡 및 기관계 구조에 미치는 구리 (Cu) 의 독성)

  • Shin, Yun Kyung;Park, Jung Jun;Ju, Sun Mi;Lee, Jung Sick
    • The Korean Journal of Malacology
    • /
    • v.31 no.2
    • /
    • pp.151-158
    • /
    • 2015
  • This study was conducted to find out the changes of survival, respiration and organ structure of Tegillarca granosa exposed to copper (Cu). Experimental period was four weeks. Experimental groups were composed of one control condition and three copper exposure conditions (0.125, 0.250 and 0.500 mg/L). The results of the study confirmed that copper induces reduction of survival rate and respiration rate and histopathology of organ structure of the bivalve. In the copper concentration of 0.500 mg/L, mortality was 66.7% after Cu exposure of 4 weeks. Respiration rate was observed exposure groups lower than control decline by 18%. Histological analysis of organ system illustrated degeneration of epithelial layer and connective tissue layer of the mantle. Also, histological degenerations as epithelial atrophy and disappearance of lateral cilia are recognized in the gill and it was observed expansion of hemolymph sinus, disruption of epithelial layer, acidification of mucous and degeneration of muscle fiber bundles in the foot. In the digestive diverticulum, it was showed atrophy and destruction of basophilic cell and epithelial cell in the digestive tubules.

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF

Extremely Low Frequency Magnetic Field is an Environmental Stress Factor by Exerting Oxidative Stress

  • Park, Yong-Jin;Park, Won-Joo;Yim, Sung-Hyuk;Yang, Seong-Jun;Sun, Yuan Lu;Jeong, Ji-Hoon;Park, Eon-Sub
    • Biomolecules & Therapeutics
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2007
  • The previous study reported the biological effect of magnetic field exerted by acting on endocrine and anti-oxidant system. The present study aims to study whether ELF-MF (extremely low frequency magnetic field) affects the physiological endocrine systems such as thyroid and whether ELF-MF affects the defense system against oxidative stress when it alters the function of thyroid. Finally, we correlate the effects of MF on oxidative stress, and adrenal and thyroid with an environmental stress factor. We exposed sham or MF to rats for 5 or 25 days. After the exposure, we determined pain sensitivity, level of TSH, $T_3$ and free $T_4$ in plasma. We also assayed in whole brain, lipid peroxidation, the activity of enzymatic anti-oxidant defense including superoxide dismutase(SOD) and glutathione peroxidase (GPx), and non enzymatic defense such as reduced or oxidized glutathione contents. MF induced the hypersensitivity to thermal stimuli with the reduction of latency. $T_3$ and $T_4$ levels were also increased by the exposure of MF. In addition, we observed the rise of MDA level in rat brain by MF although the MF did not change superoxide dismutase and glutathione peroxidase activity. The effect of MF on both reduced and oxidized glutathione results in decrease in reduced or oxidized glutathione in whole brain. In every experiment, there was no significant difference in MF influence between short term (5 days) and long term (25 days) exposure. Taken together, MF exposure affects the thyroid hormonal control in brain. The elevated thyroid hormone acts on brain, leading to hyper-utilization of oxygen. This phenomenon may be correlated with oxidative stress resulting from MF exposure. In conclusion, we suggest that MF exposure may be an environmental stress by exerting oxidative stress.

A Study of Computerized Industrial Hygiene Control System (작업환경관리 전산화에 관한 연구)

  • Lee, Song Kwon;Lee, Young Sei;Kim, Young Su;Kim, Yong Lae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.117-126
    • /
    • 1994
  • Some of the important and vital roles performed by the Health Care Center of Pohang Iron & Steel Co., Ltd.(POSCO) are the periodic monitoring of the work sites as well as regular medical check-ups for each workers to ensure both pleasant and safe working conditions and to protect employees' health. Pohang Steel Works, which has 42 plants, 26 facilities and 12,000 employees, has an annual crude steel production capacity of 9,670,000 using 24,500,000 ton of raw materials. We have measured lots of areal and personal working environment according to Occupational Safety and Health Law semiannually. All data collected on industrial hygiene is stored and managed by personal computer. The developed of a computerized industrial hygiene control system linked to the company's main computer system will provide efficient evaluation of the working environment as well as critical informations on employees' health. Development of this system had begun in May, 1992 and was completed in March, 1994. The computerized industrial hygiene control system can; 1. store industrial hygiene data, providing key pertinent to the diagnosis of occupational related illnesses, and if necessary, the basis for improving the working environment, 2. decide type and time of medical examination of each work for exposure to specific agents, and supply proper protection periodically, 3. prevent occupational related illnesses through evaluation of environmental and biological monitoring, and performance of epidemiological surveillance, 4. facilitate proper job placement through linking of industrial hygiene control and personnel information systems, 5. monitor job processes. levels of chemical agents used, and new agents introduced, 6. and increase productivity by saving time resulting from the implementation of the computerized sysyte,

  • PDF

Proactive Approach for Biofouling Control: Consequence of Chlorine on the Veliger Larvae of Mytilus edulis under Laboratory Condition

  • Haque, Niamul;Cho, Daechul;Lee, Jeong Mee;Lee, Dong Su;Kwon, Sunghyun
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.375-380
    • /
    • 2014
  • Macro fouling due to blue mussels (Mytilus edulis) has affected negatively on the operation efficiency and eventual system failure of offshore structures and coastal power stations. A certain range of chlorine (0.05, 0.1, 0.3, 0.5, 0.7 and 1.0 mg/L) was applied on the mussel larvae to identify the survival rate with respect to various exposure times under laboratory condition. The ciliary movement of the larvae was used to check their survival. The 1.0 mg/L of chlorine shows to 97% of larvae mortality whereas 0.7 mg/L of chlorine shows only 16% of larvae mortality. Minimum exposure times for 100% larvae mortality ranged from 300 to 20 min for increasing concentrations of chlorine (0.05~1.0 mg/L). It was found that 1 mg/L of chlorine was 4 times more efficient than 0.7 mg/L of that, and 15 times more than 0.05 mg/L of chlorine dose. Data collected and analyzed here will help plant operators to optimize chlorine dosage and its scheduling.

Auto Exposure control system for Compact Image Sensor Module (콤팩트 이미지 센서모듈을 위한 자동 노출제어 시스템)

  • Kim, Hyun-Sik;Jang, Won-Woo;Song, Jin-Gun;Kim, Kang-Joo;Kang, Bong-Soon
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2006.06a
    • /
    • pp.13-16
    • /
    • 2006
  • 사진을 찍을 때 카메라는 보기 좋은 사진을 얻을 수 있도록 많은 기능을 제공하고 있다. 대표적인 기능으로 자동 초점거리 조정(Auto Focus), 자동 색온도 보정(Auto White Balance), 자동 노출 조정(Auto Exposure)이 있다. 본 논문에서는 편리한 기능들 중 하나로써 자동 노출제어 시스템을 구현하였다. 본 논문에서 제안하는 자동 노출제어 시스템은 가변 시상수(Variable Time Constant)를 가지는 IIR 필터를 이용한다. Zone System에서 보여주는 사물의 휘도정보를 바탕으로 하여 이상적인 영상의 휘도 특성 그래프를 얻어내고, 이와 현재의 노출설정에서 휘도와 비교하여 적정 노출을 찾는다. 제안하는 자동 노출제어 시스템은 적정 노출을 얻을 수 있는 위치로 이동하기 위하여 기존의 마이크로 콘트롤러 등을 이용하여 구현하는 방법과 달리 간단한 구성을 가지는 IIR 필터를 이용한다. 제안하는 자동 노출제어 시스템은 간단한 구성을 가지므로 콤팩트 이미지 센서를 구성하기 위하여 사용 할 수 있다.

  • PDF