• Title/Summary/Keyword: exposure control system

Search Result 490, Processing Time 0.031 seconds

Comparison of Quality Control and Hygiene Management for Mackerels in Korea and Japan (한국과 일본의 고등어 품질 및 위생관리 비교)

  • Kim, Dae-Young
    • The Journal of Fisheries Business Administration
    • /
    • v.50 no.3
    • /
    • pp.17-29
    • /
    • 2019
  • This paper aims to find out the problems and improvement direction of quality control and hygiene management of fishery products in Korea. For this reason, we conducted a comparative analysis of quality control and hygiene management of fishing, landing and selling between Japan and Korea, taking mackerel as an example. Japan has established a systematic freshness management system from fishing to landing (production) areas and consumption areas. On the other hand, Korea is not fully lead-managed in the production area after fishing, and is distributed in a state where the quality of the product is deteriorated due to exposure to room temperature. Accordingly, a certain quality can not be secured at the final consumption stage, and sanitary problems occur. In order to improve the quality control and hygiene management of the fishery products, the following needs to be improved. First, we will improve the fishing level freshness management system. Second, we will improve the quality control and hygiene management of fish in the production area and wholesale stage. Third, we will promote the introduction of innovative sales and consignment sales systems at the production stage. Fourth, we will establish a consistent low temperature distribution system from the production area to the wholesale stage from a long-term perspective. Fifth, we will promote the development and education of manuals on fish quality and hygiene management.

Development of Innovative Neutron Flux Mapping System (혁신적인 중성자 속 분포 측정 시스템의 개발)

  • 조병학;신창훈;변승현;박준영;양장범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.60-63
    • /
    • 2004
  • An innovative in-core neutron flux mapping system has been developed and applied successfully for service in a commercial pressurized water reactor. With the benefit of double indexing path selector (Dip $s^{ⓡ}$) mechanism, the reliability of the detector drive system has been improved five times higher than that of conventional systems, and the problems caused by the serious friction generated between the detector cable and guide tubing has been solved completely because the Dip $s^{ⓡ}$ architecture allows the detector guide tubings to have larger curvature and shorter length in nature. The simple and fast maintenance is particularly emphasized in the detector drive system to secure minimum radiation exposure to the maintenance personnel by optimizing the number of components and providing easy access to the components. The programmable logic controller based digital controller with Window $s^{ⓡ}$ based operator s console provides fully automated and user friendly operation and maintenance support means.

  • PDF

Who Speaks for Innovations?: An Analysis of the Media Exposure of R&D Outputs

  • Jeong, Seongkyoon;Cho, Sukmin
    • STI Policy Review
    • /
    • v.8 no.1
    • /
    • pp.41-61
    • /
    • 2017
  • The literature in research policy extensively addresses the interaction between public R&D and the society. Scholars have paid particular attention to the way science and technology are diffused into the society and industry with the aim of substantiating their potential value. In practice, having recognized the importance of the said interaction, R&D entities and governmental organizations promote scientific and technological innovations that result from their R&D activities. Yet, the nature of news media exposure as their primary channel to promote R&D outcomes has been remarkably understudied. Using the results of R&D projects supported by the National Research Foundation of Korea (NRF), this study examines R&D entities' strategic use of the news media to publicize their outcomes. The empirical results suggest that the scale of an R&D project positively affects the counts of media exposure of its R&D outcomes, whereas the level of technology readiness and the technology life-cycle do not have significant influence. In addition, the results suggest that, compared to senior researchers, young researchers are more likely to publicize their R&D outcomes and that R&D outcomes from highly ranked universities are more likely to be publicized than those from lower-ranking universities despite our control for R&D outcomes. The aforementioned results suggest that in promoting the diffusion of science and technology, especially to the public, policymakers should be concerned about incentives for those who provide techno-scientific information, such as researchers. The social need for the diffusion of techno-scientific information into the public (e.g., technology transfer and diffusion) is an insignificant factor in determining the media exposure of such information, whereas personal benefits and sensitive issues related to a researcher's own R&D activities (e.g., justification for R&D activities) drive researchers to publicize their R&D outcomes. This paper suggests that policymakers, especially those concerned with better diffusion of scientific and technological innovations need to design a proper incentive system to maximize the societal benefits of media exposure.

A Study on the Evaluation of Radiological Effects on Workers from Air Contamination in Radioactive Waste Treatment Facilities (방사성 액체폐기물 처리 시설 내 공기오염에 의한 작업종사자 방사선학적 영향 평가에 대한 연구)

  • Min-Ho Lee;Woo-Beom Ha;Sang-Heon Lee;Jong-Soon Song
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.147-153
    • /
    • 2024
  • Radioactive liquid waste generated during operation and overhaul is collected and reused through the radioactive liquid waste treatment system and continuous monitoring system in the nuclear power plant or discharged to the outside if it satisfies the limit within the control and monitoring. However, there are concerns about boric acid management, which controls the power output of nuclear power plants in radioactive liquid waste. Due to the behavior of boric acid, it is difficult to remove it in the existing liquid radwaste system, and the concentration of boric acid water discharged tends to be higher than the natural state of 5 ppm, so additional facilities should be considered. Therefore, this study aims to evaluate the radiological effects of radioactive waste treatment facilities that are under development and use them as a basis for managing worker exposure and evaluating the safety of facilities in the future.

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Intelligent Sprayer System using Tree Recognition (과수 인식을 이용한 지능형 방제기 시스템 개발)

  • Hong, Hyung Gil;Woo, Seong Yong;Song, Su Hwan;Oh, Jang Seok;Yun, Haeyong;Seo, Kab Ho;Kwon, Soon Wook;Lee, Ki Yong;Lee, Jang Chang;Cho, Hee Keun
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.2
    • /
    • pp.115-123
    • /
    • 2020
  • Farmers using conventional sprayer system are exposed to pesticide poisoning and soil pollution due to pesticide application. In order to reduce this problem, the effective sprayer system is required. In this paper, we propose development of intelligent sprayer system using tree recognition. This intelligent sprayer system consists of an image recognition module, a remote control, a sprayer system, an air blower, and a control module. It is possible to spray pesticides automatically and manually through remote control using cameras and controls. We conducted a total of four experiments in tree recognition experiment, test of attachment and water sensitive papers, measurement of pesticide consumption, and measurement of worker exposure. The test results showed that the consumption of pesticides could be reduced while giving the same effect as conventional controls.

The Usability Assessment of Self-developed Phantom for Evaluating Automatic Exposure Control System Using Three-Dimensions Printing (자동노출제어장치 평가를 위한 3D 프린팅 기반의 자체 제작 팬텀의 유용성 평가)

  • Lee, Ki-Baek;Nam, Ki-Chang;Kim, Ho-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.147-153
    • /
    • 2020
  • This study was to evaluate the usability of self-developed phantom for evaluating automatic exposure control (AEC) using three-dimensions (3D) printer. 3D printer of fused deposition modeling (FDM) type was utilized to make the self-developed AEC phantom and image acquisitions were conducted by two different type of scanners. The self-developed AEC phantom consisted of four different size of portions. As a result, two types of phantom (pyramid and pentagon shape) were created according to the combination of the layers. For evaluating the radiation dose with the two types of phantom, the values of tube current, computed tomography dose index volume (CTDIvol), and dose length product (DLP) were compared. As a result, it was confirmed that the values of tube current were properly reflected according to the thickness, and the CTDIvol and DLP were not significantly changed regardless of AEC functions of different scanners. In conclusion, the self-developed phantom by using 3D printer could assess whether the AEC function works well. So, we confirmed the possibility that a self-made phantom could replace the commercially expensive AEC performance evaluation phantom.

DEVELOPMENT OF CONTROL SOFTWARES FOR IMPROVEMENT OF TRACKING EFFICIENCY OF THE 16'' TELESCOPE OF SEOUL NATIONAL UNIVERSITY OBSERVATORY (서울대학교 천문대 16인치 망원경의 추적 성능 향상을 위한 제어 소프트웨어의 개발)

  • JEONG WOONGSEOB;LEE SANG-GAK;PARK SOOJONG
    • Publications of The Korean Astronomical Society
    • /
    • v.14 no.1
    • /
    • pp.47-56
    • /
    • 1999
  • We have improved the control and driving system of 16' reflector at Kwanak Observatory at Seoul National University, by completing encoder unit, and by developing programs for correction of errors resulting from hardware defects. The hardware defects of this telescope system are the large backlash and the nonuniform tracking and pointing. The telescope pointing accuracy for RA is improved to a few arc minutes, and that for DEC is several tens of arc minutes. The guiding error is improved to 0.7 arcsec/minute, allowing up to 3 minutes exposure for CCD imaging under typical seeing conditions at the Observatory.

  • PDF

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

  • Dong, Ren G.;Sinsel, Erik W.;Welcome, Daniel E.;Warren, Christopher;Xu, Xueyan S.;McDowell, Thomas W.;Wu, John Z.
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.159-173
    • /
    • 2015
  • The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.