• Title/Summary/Keyword: exposure condition

Search Result 1,067, Processing Time 0.031 seconds

Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions (소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교)

  • Kang, A-Rum;Lee, In-Ja;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.355-361
    • /
    • 2017
  • Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography (디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건)

  • Lee, Won-Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

A Study on Reduction of Exposure Dose in Tomography of the Chest (흉부단층촬영시(胸部斷層撮影時) 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Lino, Yu;Lee, Man-Koo;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya;Park, Yong-Hee;Kim, Chang-Nam;Shin, Tong-Sik
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.29-35
    • /
    • 1994
  • Tomographic examination requires several times of exposure usually, therefore, reduction of radiation dose per exposure without loss of image quality proves of great benefit to patient. We compared the exposure doses under the following experimental conditions, A and B. A is the combination of SRO 380(rare earth screen) and SRH(high contrast film) with additional Cu filters or without. B is the widely used combination which is BH-III and Cronex-4 without additional filter. As a result, comparing with the condition B, the condition A with additional filter of Cu 0.15 mm + Al 0.7 mm, Cu 0.4 mm+ Al 0.4 mm and Cu 0.8 mm showed better Image quality and lower surface dose, 44 %, 31 % and 24 % of the condition B, respectively.

  • PDF

Influence of Exposure Environmental Conditions on the Crack Healing Performance of Self-healing Repair Mortar Specimens (노출환경 조건이 자기치유형 보수 모르타르 시험체의 균열 치유성능에 미치는 영향)

  • Lee, Woong-Jong;Lee, Hyun-Ho;Ahn, Sang-Wook;Lee, Kwang-Myong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.283-288
    • /
    • 2018
  • Since the crack self-healing materials are activated according to the exposure environmental conditions from the time of crack occurrence, it is very important to clarify the relationship between the healing performance and the exposure environmental conditions of the crack surface. In this paper, the influence of the exposure environmental conditions on the crack healing performance of self-healing repair mortar was investigated through the water permeability test. The influence of temperature and humidity on the crack width of cracked specimens was evaluated. As a result of measuring the change of the crack width, the effect of curing temperature was negligible but it was confirmed that crack-closing occurred due to the change of dry-wet condition. The healing materials produced on the crack surface of the specimens was identified as calcite minerals. Since the minerals with high density are precipitated under the influence of gravity, the healing performance is somewhat different according to the direction of the crack surface, and the healing performance was significantly improved in the wet exposure condition than the air exposure condition.

Memory in visual search: Evidence from search efficiency (시각 탐색에서의 기억: 탐색 효율성에 근거한 증거)

  • Baek Jongsoo;Kim Min-Shik
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • Since human visual system has limited capacity for visual information processing, it should select goal-relevant information for further processing. There have been several studies that emphasized the possible involvement of memory in spatial shift of selective attention (Chun & Jiang, 1998, 1999; Klein, 1988; Klein & MacInnes, 1999). However, other studies suggested the inferiority of human visual memory in change detection(Rensink, O'Regan, & Clark, 1997; Simons & Levin, 1997) and in visual search(Hotowitz & Wolfe, 1998). The present study examined the involvement of memory in visual search; whether memory for the previously searched items guides selective attentional shift or not. We investigated how search works by comparing visual search performances in three different conditions; full exposure condition, partial exposure condition, and partial-to-full exposure condition. Revisiting searched items was allowed only in full exposure condition and not in either partial or partial-to-full exposure condition. The results showed that the efficiencies of attentional shift were nearly identical for all conditions. This finding implies that even in full exposure condition the participants scarcely re-examined the previously searched items. The results suggest that instant memory can be formed and used in visual search process. These results disagree with the earlier studies claiming thar visual search has no memory. We discussed the problems of the previous research paradigms and suggested some alternative accounts.

  • PDF

The Study of Optimal Acquisition Condition and Image Processing (최적의 촬영조건 및 영상처리에 관한 연구)

  • Lee, Yong-Gu;Shin, Jong-Ho;Seo, Kyoung-Eun;Choi, Yoo-Lee;Lee, Soo-Hyeon;Lee, Young-Jin;Kim, Hee-Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.221-226
    • /
    • 2014
  • In this paper, we achieved the study which determined the excellent diagnostic condition and searched the exposure condition with the minimum radiation exposure level having the equal diagnostic ability. To accomplish these study, chest phantom images with lesions and without ones were evaluated at various exposure conditions. With respect to the phantom with lesions and without ones, we obtained the chest PA imaging applied by photographing parts of DR apparatus and the images processed as histogram equalization and edge enhancement method. The images were acquired at the exposure conditions of 2.0, 2.5, 3.2, 4.0 and 5.0mAs. The morphological analysis was performed by ROC curves using the images obtained at each exposure condition. The exposure conditions with the most excellent diagnostic ability and with the equal diagnostic capability having the minimum radiation exposure level were determined by means of sensitivity, specificity and accuracy.

Health Risk Assessment and VOCs Levels of Residents in Industrial Area (광양만권 공단지역 일부 지역 주민들의 VOCs 노출농도 및 건강위해성 평가)

  • Lee, Che-Won;Choi, Su-Hyeon;Hong, Sung-Chul;Chung, Eun-Kyung;Chung, Yong-Taik;Yang, Won-Ho;Lee, Jong-Dae;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1373-1382
    • /
    • 2011
  • This research had been conducted from May to October 2007, studying 110 residents of G, Y, H industrial area in Jun-nam province. It is designed to understand the difference in levels of indoor, outdoor and personal exposure to VOCs(benzene, toluene, Ethylbenzene) and a health risk assessment was conducted to see if there was any fatal cause from carcinogenic or non - carcinogenic elements from a case group and a control group in all areas as well as each different area. In the case of benzene in the air, the geometric levels for the case group are indoor, outdoor and personal exposure; a higher than for the control group. As a results of the Monte - Carlo study about benzene, it shows that the case group's carcinogenicity is higher than that of the control group and it also shows that, on the CTE, RME condition and Monte - Carlo analysis, all subjects are seen to exceed the carcinogenicity tolerance $10^{-6}$ of US EPA. In the case of toluene, ethylbenzene on the CTE, RME condition and Monte - Carlo analysis, these do not exceed the non - carcinogenic standard of 1, but toluene in RME condition for both groups' personal exposure and the indoor and personal exposure of ethylbenzene in Monte - Carlo show that these seem to exceed the standard.

Analysis of Original and Processing Image by Control of Exposure Dose, kVp in Digital Radiography (디지털 방사선에서 조사선량과 관전압조절에 의한 원본영상과 처리영상 분석)

  • Kim, Bo-Ra;Ryu, Sin-Young;Seok, Jin-Young;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Dynamic range on the digital detector can be a representation to the ratio of maximum and minimum of pixel value. Wide dynamic range and post processing ability of the digital detector made difficult to recognize visually to high or low dose images. We were evaluated a change of mean pixel value on the original and processed image, when we controlled the kVp, mA, exposure time on the digital detector. On the kVp of a constant condition, we were acquired an original and processed image by changes of mA, exposure time. According to the thickness of the subject under the same conditions, to determine a relation of pixel value and X-ray intensity, we used an aluminum step wedge. When mA and exposure times were changed under the kVp of a constant condition, the X-ray intensity was decreased by the reduction of the mean pixel value. In addition when kVp was increased in a constant condition of mAs, the mean pixel value was increased according to the increment of the X-ray intensity. Therefore, low kVp, high mA and short exposure time were a way to reduce a patient dose.

  • PDF

Evaluation of Applicability of Circuit-analog Radar Absorbing Structures for High Temperature in 350℃ and Hot-wet Environment (고온용 Circuit-analog 전파흡수구조의 350℃ 및 열 수분 환경에서의 적용성 평가)

  • Min-Su Jang;Ho-Beom Kim;Heon-Suk Hong
    • Composites Research
    • /
    • v.36 no.5
    • /
    • pp.335-341
    • /
    • 2023
  • We proposed a high-temperature circuit-analog radar absorbing structures (CA-RAS), and evaluated radar absorption performance and tensile properties in 350℃ and a hot-wet environment. The CA-RAS was implemented with a glass/cyanate ester composites and a square resistive pattern layer, and reflection loss was measured by 350℃ and after exposure of hot-wet condition using free space measurement. And the tensile strength at 350℃ and after exposure of hot-wet condition was measured according to the ASTM D638. The proposed CA-RAS showed a 4 GHz of -dB bandwidth and -20 dB of a peak value at 350℃. In addition, there was no deterioration in absorption performance after exposure to a hot-wet condition. The tensile strength value of more than 95% compared to the strength of the glass/cyanate ester composite was confirmed at 350℃ and after exposure of hot-wet condition. Through this, the applicability of CA-RAS proposed in this study was confirmed as a load bearing structure for stealth weapon exposed to high temperature and hot-wet environment.

Estimation of Multimedia Environmental Distribution for Benzoyl peroxide Using EQC Model (EQC 모델을 이용한 벤조일 퍼록사이드의 다매체 환경거동 예측)

  • Kim, Mi-Kyoung;Bae, Hee-Kyung;Song, Sang-Hwan;Koo, Hyun-Ju;Kim, Hyun-Mi;Choi, Kwang-Soo;Jeon, Sung-Hwan;Lee, Moon-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1090-1098
    • /
    • 2005
  • Benzoyl peroxide is very toxic to aquatic organisms but environmental concentration or exposure effects were not studied. Distribution of the chemical among multimedia environment was estimated using EQC(Equilibrium Criterion) model based on the physical-chemical properties to evaluate the risk of benzoyl peroxide in environment. Level I describes a situation that 100,000 kg of benzoyl peroxide is emitted into the environment which is equilibrium and steady-state without degradation and advection condition. Level II describes a situation that a constant rate of 1,000kg/h of benzoyl peroxide is continuously discharged into the environment which is equilibrium and steady-state with degradation and advection condition. Level III describes a situation that 1,000 kg/h of benzoyl peroxide is continuously introduced in each air, water, soil, and sediment compartment which are non-equilibrium and steady-state with degradation, advection, and inter-media transfer condition. In Level I and II calculations the chemical was distributed to soil(68.3%) and water(28.7%). In Level III calculation it was primarily distributed to soil(99.9%) and overall residence time was estimated to be 3.4 years. Benzoyl peroxide can be persistent in environment.