• Title/Summary/Keyword: exposure classification

Search Result 182, Processing Time 0.02 seconds

Evaluation of system design modifications for full system decontamination of Kori Unit 1

  • Kim, HakSoo;Kim, JeongJu;Kim, ChoRong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3949-3956
    • /
    • 2022
  • Kori Unit 1 is planning a system decontamination project to reduce radiation exposure of decommissioning workers, prevent the spread of contamination and down-grade the level of classification of radioactive waste. The system decontamination range for Kori Unit 1 will be the entire primary system, including RCS, CVCS and RHRS. Some system design modifications are required for the system decontamination operation. In this paper, major system design modifications were evaluated based on the conditions that system restoration is needed after completion of system decontamination. The major system design modifications are CIDF connection location to system, system decontamination operating pressure control, RCP seal water injection and formation of letdown flow. It was evaluated that there was no negative effect on the system due to the system design modifications. However, as the RCP seal water is injected into the system in the oxidation process, the concentration of the oxidizing agent is diluted. Therefore, the oxidizing agent injection and system decontamination operation procedures should be developed to address the dilution effect of the oxidizing agent. The system design modifications dealt in this paper will be finally confirmed through on-site investigation in the future, and if necessary, the system design modifications will be re-evaluated.

Anomaly detection of isolating switch based on single shot multibox detector and improved frame differencing

  • Duan, Yuanfeng;Zhu, Qi;Zhang, Hongmei;Wei, Wei;Yun, Chung Bang
    • Smart Structures and Systems
    • /
    • v.28 no.6
    • /
    • pp.811-825
    • /
    • 2021
  • High-voltage isolating switches play a paramount role in ensuring the safety of power supply systems. However, their exposure to outdoor environmental conditions may cause serious physical defects, which may result in great risk to power supply systems and society. Image processing-based methods have been used for anomaly detection. However, their accuracy is affected by numerous uncertainties due to manually extracted features, which makes the anomaly detection of isolating switches still challenging. In this paper, a vision-based anomaly detection method for isolating switches, which uses the rotational angle of the switch system for more accurate and direct anomaly detection with the help of deep learning (DL) and image processing methods (Single Shot Multibox Detector (SSD), improved frame differencing method, and Hough transform), is proposed. The SSD is a deep learning method for object classification and localization. In addition, an improved frame differencing method is introduced for better feature extraction and a hough transform method is adopted for rotational angle calculation. A number of experiments are conducted for anomaly detection of single and multiple switches using video frames. The results of the experiments demonstrate that the SSD outperforms the You-Only-Look-Once network. The effectiveness and robustness of the proposed method have been proven under various conditions, such as different illumination and camera locations using 96 videos from the experiments.

Endovascular embolization of persistent liver injuries not responding to conservative management: a narrative review

  • Simon Roh
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.165-171
    • /
    • 2023
  • Trauma remains a significant healthcare burden, causing over five million yearly fatalities. Notably, the liver is a frequently injured solid organ in abdominal trauma, especially in patients under 40 years. It becomes even more critical given that uncontrolled hemorrhage linked to liver trauma can have mortality rates ranging from 10% to 50%. Liver injuries, mainly resulting from blunt trauma such as motor vehicle accidents, are traditionally classified using the American Association for the Surgery of Trauma grading scale. However, recent developments have introduced the World Society of Emergency Surgery classification, which considers the patient's physiological status. The diagnostic approach often involves multiphase computed tomography (CT). Still, newer methods like split-bolus single-pass CT and contrast-enhanced ultrasound (CEUS) aim to reduce radiation exposure. Concerning management, nonoperative strategies have emerged as the gold standard, especially for hemodynamically stable patients. Incorporating angiography with embolization has also been beneficial, with success rates reported between 80% and 97%. However, it is essential to identify the specific source of bleeding for effective embolization. Given the severity of liver trauma and its potential complications, innovations in diagnostic and therapeutic approaches have been pivotal. While CT remains a primary diagnostic tool, methods like CEUS offer safer alternatives. Moreover, nonoperative management, especially when combined with angiography and embolization, has demonstrated notable success. Still, the healthcare community must remain vigilant to complications and continuously seek improvements in trauma care.

Relevance of the Watson-Jones anterolateral approach in the management of Pipkin type II fracture-dislocation: a case report and literature review

  • Nazim Sifi;Ryad Bouguenna
    • Journal of Trauma and Injury
    • /
    • v.37 no.2
    • /
    • pp.161-165
    • /
    • 2024
  • Femoral head fractures with associated hip dislocations substantially impact the functional prognosis of the hip joint and present a surgical challenge. The surgeon must select a safe approach that enables osteosynthesis of the fracture while also preserving the vascularization of the femoral head. The optimal surgical approach for these injuries remains a topic of debate. A 44-year-old woman was involved in a road traffic accident, which resulted in a posterior iliac dislocation of the hip associated with a Pipkin type II fracture of the femoral head. Given the size of the detached fragment and the risk of incarceration preventing reduction, we opted against attempting external orthopedic reduction maneuvers. Instead, we chose to perform open reduction and internal fixation using the Watson-Jones anterolateral approach. This involved navigating between the retracted tensor fascia lata muscle, positioned medially, and the gluteus medius and minimus muscles, situated laterally. During radiological and clinical follow-up visits extending to postoperative month 15, the patient showed no signs of avascular necrosis of the femoral head, progression toward coxarthrosis, or heterotopic ossification. The Watson-Jones anterolateral approach is a straightforward intermuscular and internervous surgical procedure. This method provides excellent exposure of the femoral head, preserves its primary vascularization, allows for anterior dislocation, and facilitates the anatomical reduction and fixation of the fracture.

A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography (소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2016
  • In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.

A Study on Establishment of Buffer Zone of Radioactive Waste Repository (방사성패기물 처분시설에서의 완충공간 설정에 대한 고찰)

  • Yoon, Jeong-Hyoun;Park, Joo-Wan;Ju, Min-Su;Kim, Chang-Lak;Park, Jin-Baek
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • A new proposed repository has a final capacity of 800,000 drums radioactive waste. Most of foreign repositories have a general practice of segregating control zones which mainly contributes to classification of degree of control, whether it is called buffer zone or not. Domestic regulatory requirements of establishment of buffer zone in a repository are not much different from those of nuclear power plants for operation period, in which satisfactory design objective or performance objective is the most important factor in determination of the buffer zone. The meaning of buffer zone after closure is a minimum requested area which can prevent inadvertant intruders from leading to non-allowable exposure during institutional control period. Safety assessment with drinking well scenario giving rise to the highest probability of exposure among the intruder's actions can verify fulfillment of the buffer zone which is determined by operational safety of the repository. At present. for the repository to be constructed in a few years, the same procedure and concept as described in this paper are applied that can satisfy regulatory requirements and radiological safety as well. However, the capacity of the repository will be stepwise extended upto 800,000 drums, consequently its layout will be varied too. Timely considerations will be necessary for current boundary of the buffer zone which has been established on the basis of 100,000 drums disposal.

  • PDF

Study on Health Risk Assessment of Carcinogenic Chemicals in Drinking Water (음용수 중 유해 화학 물질에 대한 위해성 평가에 관한 연구 - I. 발암성 화학 물질을 중심으로 -)

  • Chung, Yong;Shin, Dong-Chun;Kim, Jong-Man;Park, Seong-Eun;Yang, Ji-Yeon;Lee, Ja-Koung;Hwang, Man-Sik;Park, Yeon-Shin
    • Environmental Analysis Health and Toxicology
    • /
    • v.10 no.1_2
    • /
    • pp.1-14
    • /
    • 1995
  • The purpose of this research is to assess the health risk of pollutants in drinking water and recommend the guidelines and management plans for maintaining good quality of drinking water. This study has been funded as a national project for three years from 1992 to 1995. This study(the second year, 1993-1994) was conducted to monitor 32 species of carcinogenic chemicals such as volatile organic compounds(VOCs), polynuclear aromatic hydrocarbons(PAHs), pesticides and heavy metals of drinking water at some area in six cities of Korea, and evaluate health risk due to these chemicals through four main steps of risk assessment in drinking water. In hazard identification, 32 species of carcinogenic chemicals were identified by the US EPA classification system. In the step of exposure assessment, sampling of raw, treated and tap water from the public water supply system had been conducted from 1993 to 1994, and 32 chemicals were analyzed. In dose-response assessment, cancer potencies, unit risk estimates and virtually safe doses of carcinogens were obtained by TOX-RISK (Version 3.1). In risk characterization of detected chemicals, health risk due to carcinogens such as vinyl chloride, carbon tetrachloride, dichloromethane, 1, 2-dichloromethane, chloroform, benzene and arsenic of tap water in several cities exceeded 10$^{-5}$ level. We suggest that non-regulated chemicals which exceed 10$^{-5}$ excess cancer risk level, such as vinyl chloride, carbon tetrachloride and 1, 2-dichloroethane, should be monitored periodically and be regulated by the Drinking Water Management Act, and database for exposure parameter of our own situation should be established.

  • PDF

Vehicle Headlight and Taillight Recognition in Nighttime using Low-Exposure Camera and Wavelet-based Random Forest (저노출 카메라와 웨이블릿 기반 랜덤 포레스트를 이용한 야간 자동차 전조등 및 후미등 인식)

  • Heo, Duyoung;Kim, Sang Jun;Kwak, Choong Sub;Nam, Jae-Yeal;Ko, Byoung Chul
    • Journal of Broadcast Engineering
    • /
    • v.22 no.3
    • /
    • pp.282-294
    • /
    • 2017
  • In this paper, we propose a novel intelligent headlight control (IHC) system which is durable to various road lights and camera movement caused by vehicle driving. For detecting candidate light blobs, the region of interest (ROI) is decided as front ROI (FROI) and back ROI (BROI) by considering the camera geometry based on perspective range estimation model. Then, light blobs such as headlights, taillights of vehicles, reflection light as well as the surrounding road lighting are segmented using two different adaptive thresholding. From the number of segmented blobs, taillights are first detected using the redness checking and random forest classifier based on Haar-like feature. For the headlight and taillight classification, we use the random forest instead of popular support vector machine or convolutional neural networks for supporting fast learning and testing in real-life applications. Pairing is performed by using the predefined geometric rules, such as vertical coordinate similarity and association check between blobs. The proposed algorithm was successfully applied to various driving sequences in night-time, and the results show that the performance of the proposed algorithms is better than that of recent related works.

Standardization of work environment measurement information for constructing exposure surveillance system (노출감시체계 구축을 위한 작업환경측정 정보 표준화)

  • Choi, Sangjun;Jeong, Jee Yoen;Im, Sungguk;Lim, Daesung;Koh, Dong-Hee;Park, Donguk;Park, YunKyung;Kim, Soyeon;Chung, Eunkyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.322-335
    • /
    • 2019
  • Objectives: The goal of this study is to standardize industry, process, and job within work environment measurement information. Methods: We selected 180 work environment measurement reports on 30 industries from a database monitored from 2014 to 2016 by the Korea Industrial Health Association. Ten industrial hygienists, each with over five years of experience in measurement, conducted a primary standardization of 180 reports. Two professional industrial hygienists with more than 20 years of experience each reviewed and revised the results of the primary standardization. We also examined the validity on the usefulness of the standardized database by the two industrial hygienists. Results: The final standardization results were classified into eight major categories, 23 sub-major categories, 39 minor categories, 53 unit categories and 70 sub-unit categories in the Korean Standard Industrial Classification (KSIC) 10th revision. A total of 161 processes were standardized, and there were 148 processes with K2B codes. Standard job was coded into 13 job groups including operator, automobile maintenance, nurse, maintenance, manager, excavating machine operator, forklift driver, radiologist, clinical pathologist, signer, researcher, kitchen assistant, and concrete reinforcement ironworker. Conclusions: Although the standardized information in this study may be only a part of the total information, it can be useful for improvement of the K2B system. Additional research is needed for an ongoing clean-up of data in the K2B and re-calibration and reclassification of standard processes until the future national exposure monitoring system is fully established.

Secure Key Exchange Protocols against Leakage of Long-tenn Private Keys for Financial Security Servers (금융 보안 서버의 개인키 유출 사고에 안전한 키 교환 프로토콜)

  • Kim, Seon-Jong;Kwon, Jeong-Ok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.3
    • /
    • pp.119-131
    • /
    • 2009
  • The world's widely used key exchange protocols are open cryptographic communication protocols, such as TLS/SSL, whereas in the financial field in Korea, key exchange protocols developed by industrial classification group have been used that are based on PKI(Public Key Infrastructure) which is suitable for the financial environments of Korea. However, the key exchange protocols are not only vulnerable to client impersonation attacks and known-key attacks, but also do not provide forward secrecy. Especially, an attacker with the private keys of the financial security server can easily get an old session-key that can decrypt the encrypted messages between the clients and the server. The exposure of the server's private keys by internal management problems, etc, results in a huge problem, such as exposure of a lot of private information and financial information of clients. In this paper, we analyze the weaknesses of the cryptographic communication protocols in use in Korea. We then propose two key exchange protocols which reduce the replacement cost of protocols and are also secure against client impersonation attacks and session-key and private key reveal attacks. The forward secrecy of the second protocol is reduced to the HDH(Hash Diffie-Hellman) problem.