• Title/Summary/Keyword: exponentiality

검색결과 44건 처리시간 0.016초

Electron Tunneling and Electrochemical Currents through Interfacial Water Inside an STM Junction

  • Song, Moon-Bong;Jang, Jai-Man;Lee, Chi-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권1호
    • /
    • pp.71-74
    • /
    • 2002
  • The apparent barrier height for charge transfer through an interfacial water layer between a Pt/Ir tip and a gold surface has been measured using STM technique. The average thickness of the interfacial water layer inside an STM junction was controlled by the amount of moisture. A thin water layer on the surface was formed when relative humidity was in the range of 10 to 80%. In such a case, electron tunneling through the thin water layer became the majority of charge transfers. The value of the barrier height for the electron tunneling was determined to be 0.95 eV from the current vs. distance curve, which was independent of the tip-sample distance. On the other hand, the apparent barrier height for charge transfer showed a dependence on tip-sample distance in the bias range of 0.1-0.5 V at a relative humidity of approximately 96%. The non-exponentiality for current decay under these conditions has been explained in terms of electron tunneling and electrochemical processes. In addition, the plateau current was observed at a large tip-sample distance, which was caused by electrochemical processes and was dependent on the applied voltage.

모수가 미지인 상황에서의 지수분포성 적합도 검정방법 (A goodness - of - fit test for the exponential distribution with unknown parameters)

  • 김부용
    • 응용통계연구
    • /
    • 제4권2호
    • /
    • pp.157-170
    • /
    • 1991
  • 본 논문은 척도모수와 위치모수가 알려지지 않은 상황에서의 지수분포성 적합도 검정문제를 다루고 있다. 기존의 검장방법들과는 달리 누적분포 함수와 경험분포 함수 사이의 편차의 $L_1$-norm에 바탕을 두고 둔 새로운 검정방법이 제시되었으며, Monte Carlo 방법에 의하 여 검정통계량의 임계치를 구하였다. 그리고 표본의 크기가 작은 경우에 한하여 제시된 검 전통계량의 분포가 파악되었다. 한편 이 검정방법의 검정력을 기존의 검정방법들과 비교하 기 위하여 응용분야에서 흔히 사용되는 몇가지 분포형태에 대하여 검정력을 측정하였다. 그 결과, 새로운 검정방법이 보수적인 검정임에도 불구하고 다른 검정방법에 비하여 상대적으 로 검정력이 우수한 것으로 나타났다.

  • PDF

POSS를 함유한 PMMA 박막의 유리전이온도 및 등온 물리적 시효 (Glass Transition Temperature and Isothermal Physical Aging of PMMA Thin Films Incorporated with POSS)

  • 진실로;이종근
    • 폴리머
    • /
    • 제36권4호
    • /
    • pp.507-512
    • /
    • 2012
  • 순수 PMMA와 methacryl-polyhedral oligomeric silsesquioxane(Ma-POSS)를 5 wt% 첨가한 PMMA를 박막(~650 nm)과 초박막(~50 nm)으로 제조하였으며, 유리전이온도($T_g$)와 등온 물리적 시효에 미치는 박막의 두께에 미치는 POSS의 첨가 효과를 시차주사열량계(DSC)를 이용하여 조사하였다. 초박막화와 Ma-POSS의 첨가로 인해 $T_g$ 감소가 관찰되었다. 또한 등온 물리적 시효에 의한 엔탈피 완화값(${\Delta}H_{Relax}$)도 초박막화 Ma-POSS를 첨가하였을 때 감소하였다. 시효시간에 따른 ${\Delta}H_{Relax}$ 데이터에 KWW(Kohlrausch-Williams-Watts)식을 적용하여 최대 엔탈피(${\Delta}H_{\infty}$), 이완시간(${\tau}$) 그리고 이완시간의 분포상수(${\beta}$)를 결정하였으며 이를 비교 분석하였다.

$^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용 (Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling)

  • 천인국;황경훈;이상윤;김진수;이재성;신희원;이민경;윤민기;최원식
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권4호
    • /
    • pp.275-284
    • /
    • 2008
  • 목적: 정상 성인에서 심근의 산소 소모량에 대한 참고범위를 구하고 시간-방사능 곡선(time-activity curve, TAC)에 재순환이 어떤 영향을 미치는지 알아보기 위하여 재순환 교정법과 수정 단일구획모델을 적용하여 심근 내 산소 소모량을 계산하고자 하였다. 대상 및 방법: 평균연령 $26.3{\pm}4.0$세인 9명의 지원자들에서 925 MBq (25mCi)의 $^{11}C$-Acetate (가천의과학대학교 뇌과학연구소)와 PET/CT (Biograph 6, 독일 지멘스사)를 사용하여 심근 산소 소모량을 계산하였다. 자료의 분석을 위하여 $MATLAB^{(R)}$ v7.1 (Mathworks. Inc., 미국), $Excel^{(R)}$ 2007 (Microsoft, 미국), $SPSS^{(R)}$ v12.0 (Apache Software Foundation, 미국) 등의 소프트웨어들을 사용하였다. PET/CT로 촬영한 영상으로부터 10초마다 12장, 다음 60초마다 5장, 다음 120초마다 3장, 그리고 마지막으로 300초마다 2장 등 0초일 때 1장을 포함하여 총 23개 프레임을 추출하였다. 수정 단일구획모델과 재순환 교정법을 적용하였다. 통계적 분석방법으로 정규성 검정, 분산분석(ANOVA), 사후분석(Post-Hoc analysis) 등을 이용하였고 p값으로 0.05를 적용하였다. 결과: 심근 산소 소모량의 참고범위는 중격 아래벽, 가쪽벽, 앞벽, 전체벽에서 각각 $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ 등으로 계산되었다. 또한 시간-방사능 곡선의 형태에 관한 기존의 이중적 견해는 결국 재순환된 $^{11}C$-Acetate 때문이며 이 재순환을 교정하면 곡선은 근본적으로 단일 지수함수 형태를 띤다. 결론: $^{11}C$-Acetate 및 3차원 PET/CT로 심근의 산소 소모량을 효율적으로 평가할 수 있으며 안정상태에서는 재순환된 $^{11}C$가 거의 존재하지 않기 때문에 시간-방사능 곡선에 의미 있는 영향을 미치지 않는다..