• Title/Summary/Keyword: experimental manual

Search Result 524, Processing Time 0.028 seconds

System Implementation for Automatic Inspection of Wind Pressure Sensor Based on Reliability Improvement (신뢰성 향상 기반의 풍압센서 자동검사 시스템구현)

  • Do, Nam Soo;Ryu, Conan K.R.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.775-778
    • /
    • 2017
  • This research describes system implementation for automatic inspection on wind pressure sensor production based on reliability improvement. The reliability is minimized by the automatic inspection system on the wind pressure sensor against the manual system. The system consists of the control system and monitoring system to be scanning the inspection processing. The inspection system for reliability is evaluated in Gage Repeatability and Reproducibility. The experimental results are improved about 2 times speed, measured error ${\pm}0.02V$, effectiveness 15%, missing probability 17% and false alarm 12% respectively. The system will be also improved by database and the product barcodes for the total quality control system based on the effective reliability in the future.

  • PDF

Effects of Self-breast Pumping in Primiparous Women after Cesarean Delivery (제왕절개술 초산모의 자가 착유 행위 효과)

  • Yeo, Jung-Hee;Moon, Guil-Nam;Lee, Sun-Ok
    • Women's Health Nursing
    • /
    • v.18 no.2
    • /
    • pp.98-107
    • /
    • 2012
  • Purpose: This study was done to identify the effects of self-breast pumping on breastfeeding rates and, the degree of breast milk fullness among primiparous women giving birth by cesarean section. Methods: The study design was a non-synchronized posttest control group experiment with repeated measures. The participants were 60 women, 31 in the experimental group who used a manual pump 5 times a day after exclusive breastfeeding and 29 in the control group who breastfed exclusively with no other interventions. Results: While self-breast pumping did not improve breastfeeding rates or the degree of breast milk fullness at any of the time points studied, breastfeeding rates continued to remain high till 12 weeks postpartum in both groups. Conclusion: Although some modifications in research methods will be required to identify the effects of breast pumping and exclusive breastfeeding, both these approaches can be used as interventions to improve breastfeeding rates and breast milk quantity.

Effects of Seated Exercise of Thoracic and Abdominal Muscles on Upper Extremity Function and Trunk Muscles Activity in Patients with Chronic Stroke

  • Park, Shinjun;Kim, Sangduk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2065-2070
    • /
    • 2020
  • Background: Weakness of the abdominal and mid thoracic muscles the lead to thoracic kyphosis of stroke patients. The trunk muscles activity of stroke patients is significantly related to upper extremity. Objectives: To investigate the effect of seated exercise of thoracic and abdominal muscles on upper extremity function and trunk muscles activity in stroke patients. Design: One-group pretest-posttest design. Methods: A total of 27 stroke patients were recruited. All stroke patient were given seated abdominal exercise (posterior pelvic tilt exercises) and thoracic exercise (postural-correction exercise). All exercises were conducted for 30 minutes, three times a week for four weeks. The manual function test (MFT) and electromyography (EMG) were measured, and EMG electrodes were attached to thoracic paraspinal muscles and lower rectus abdominal muscles. EMG signal is expressed as %RVC (reference voluntary contraction). Results: Experimental group showed significant increases in abdominal muscles, paraspinal muscles activity and MFT total score, items of arm motion (forward elevation of the upper extremity, lateral elevation of the upper extremity, touch the occiput with the palm) in MFT after four weeks. Conclusion: These results suggest that, in stroke patients, seated exercise of thoracic and abdominal muscles contribute to improve trunk muscles activity and upper extremity function in stroke patients.

On Automatic Apparatus for Cryoscopy and Improvement in Experimental Method (Cryoscopy 裝置와 方法의 改良에 關한 硏究)

  • Shin, Yun-Kyong;Lee, Joon
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.2
    • /
    • pp.143-149
    • /
    • 1974
  • The traditional cryoscopic measurement had performed by inconvenient manual operation which accompanies various unavoidable errors. For example, the irregularity of hand stirring, difference of visual angle in reading Beckmann thermometer and furthermore, its large heat capacity acts as the decreasing effect of the sensitivity. In these studies, the author devised new automatically measuring cryoscopic apparatus with temperature recording system in which temperature variation is changed to electric current. The light beam from the galvanometer is absorbed by the photographic paper on the rotating cylinder. On the other hand, the use of sodium sulfate decahydrate in cryoscopy causes considerable error, because small crystal particles adhere on the upper wall of the measuring tube. As an improvement, anhydrous sodium sulfate is used and then the desired amount of water is added.

  • PDF

Determination of Aqueous Ammonia with Indophenol Method : Comparision and Evaluation for the Reaction-Rate, Equilibrium and Flow-Injection Analysis Methods (인도페놀법을 이용한 수용액 중 암모니아 정량에 관한 연구 : 평형법, 반응속도법, 흐름주입분석법의 비교와 평가)

  • 정형근;김범식
    • Journal of Environmental Science International
    • /
    • v.4 no.1
    • /
    • pp.91-103
    • /
    • 1995
  • The reaction rate, equilibrium, and flow injection analysis methods were fundamentally evaluated for the determination of aqueous ammonia. The selected indophenol blue method was based on the formation of indophenol blue in which ammonium ion reacted with hypochlorite and phenol in alkaline solution. In the optimized reaction condition, the reaction followed 1st order reaction kinetics and the final product was stable. The absorbance measurements before and after the equilibrium were utilized for the reaction rate and equilibrium methods. The reaction rate methods, based on the relative analytical signals for the possibility of eliminating interferents, were shown to have good linear calibration curves but the detection limit and the calibration sensitivity were poorer than those in the equilibrium method. The detection limits were 32-49 pub and 24 pub for the reaction rate and equilibrium methods, respectively In the flow injection analysis, the absorbance was measured before the equilibrium reached and thus resulted in 30% reduction of calibration sensitivity. However, the detection limit was 11 ppb, indicating that the peak-to-peak noise for the blank was remarkably improved. Compared to the manual methods, the optimized experimental condition in a closed reaction system reduced the blank absorbance and the inclusion of ammonia from the atmosphere was prevented. In addition, highly reproducible mixing of sample and reagents and analytical data extracted from continuous recording showed excellent reproducibility.

  • PDF

Magnetic Switch Auto Control Method of the High-Voltage Pulse Power Supply (고전압 펄스 전원장치용 자기스위치 자동제어 방법)

  • Kim, Soo-Hong;Lee, Jeong-Hum;Kim, Byong-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.366-373
    • /
    • 2011
  • The magnetic switch used in pulsed-power applications is superior in its high repetition rate, high stability, and long lifetime. But magnetic switch was optimized switching operation by manual control. When the load changes, the switching state can not be optimized automatically. In this paper, the auto control method of magnetic switch for high pulsed-power proposed. The magnetic switch is used capacitor charging power supply for high-voltage compressor. The proposed method can be optimized an efficiency of the system by magnetic switch auto control according to load variation. And the proposed method verify the experimental results.

Development of Interlocking Inspection Simulator for Electronic Interlocking System (전자연동장치를 위한 연동검사시스템의 개발)

  • Lee, Jae-Ho;Hwang, Jong-Gyu;Park, Young-Soo;Park, Gui-Tae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.70-76
    • /
    • 2004
  • The purpose of interlocking system in railway is to prevent the route for a train being set up and its protecting signal cleared if there were already another, conflicting route set up and the protecting signal for that route cleared. Recently, conventional relays circuitry in industrial field is replaced to computer-based control systems according to the advance of computer and communication technology. Therefore, interlocking systems in railway field are rapidly changing from existing relay-based interlocking system to computer-based electronic ones that executes the vital interlocking logic to assure the safety train routes at trackside signaling equipment room using electronic circuits. So it is very important to verify the performance of developed electronic interlocking system by plentiful laboratory testing before actually application in the railway system. However the laboratory testing in the present state of railway signaling is preformed individually by manual, so very much test time and cost are required. To solve these problems, we are developed the simulator for automatic interlocking inspection in this research. This simulator is able to operate on general personal computer and has following beneficial functions : automatic test sheet generation for inspection, automatic inspection execution and et al. The experiments are executed to test the feasibility of the developed simulator the experimental results have good agreements with the anticipated ones.

An Experimental study on the Damage to Heavy Cargoes in case of the Two Tiers Loading under Carriage bySea (해상중량물운송시 이후적된 질적 파손에 관한 실험적 연구)

  • Park, Myung-Kyu;Hugh, Il;Cho, Bum-Sik
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.2
    • /
    • pp.15-32
    • /
    • 1996
  • The Internation Maritime Organization (IMO) has required that ships other than cellular-ships which carry cargo units and other entities should be provided with a cargo securing manual. A number of serious accidents has resulted from improper stowage and insufficient securing of heavy cargo. The cargo claims caused by the accidents stated above not only reduce the number of shippers but also reduce their benefits. The following four basic safe items should be considered carefully in the carriage by sea in case of two tiers loading of heavy cargoes packed with wooden case if it is a general cargo ship. a) Safe stowing place b) Safe lashing c) Protecting crushing goods d) Adequate dunnage. All operators of cargoes must be reminded that only the proper stowge and securing of heavy cargos can prevent from the occurrence of such accidents in the future. This paper intends to analyze the unigue damage mechanism for two tiers loading of heavy cargoes on the general cargo ships encountered in the rough sea, and suggest the countermeusere to prevent the identical accidents in the future.

  • PDF

CHARACTERISTICS OF A NEW PNEUMATIC TRANSFER SYSTEM FOR A NEUTRON ACTIVATION ANALYSIS AT THE HANARO RESEARCH REACTOR

  • Chung, Yong-Sam;Kim, Sun-Ha;Moon, Jong-Hwa;Baek, Sung-Yeol;Kim, Hark-Rho;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.813-820
    • /
    • 2009
  • A rapid pneumatic transfer system (PTS) for an instrumental neutron activation analysis (INAA) is developed as an automatic irradiation facility involving the measurement of a short half-life nuclide and a delayed neutron counting system. Three new PTS designs with improved functions were constructed at the HANARO research reactor in 2006. The new system is composed of a manual system and an automatic system for both an INAA and a delayed neutron activation analysis (DNAA). The design and basic conception of a modified PTS are described, and the functions of system operation and control, radiation protection and emissions of radioactive gas are improved. In addition, a form of capsule transportation of these systems is tested. The experimental results pertaining to the irradiation characteristics with variation of the neutron flux and the temperature of the irradiation position with the irradiation time are presented, as is an analysis of the reference material for analytical quality control and uncertainty assessments.

Oscillation Motion Control of Gantry Crane System with Arm for Anti-Sway (Anti-sway용 암을 가진 겐트리 크레인의 흔들림저감 제어)

  • Kim, H.S.;Park, H.S.;Lee, D.H.;Park, J.H.;Kim, S.B.
    • Journal of Power System Engineering
    • /
    • v.2 no.1
    • /
    • pp.73-79
    • /
    • 1998
  • In practical fields, the sway of crane systems leads to extra stress to the crane structure during the transporting operation and it is in close connection with its life. Usually, when we operate the cranes with high speed and manual control, the sway motion is irreducible. In this paper, a new type of crane system is proposed to avoid the irreducible sway of the crane systems. The proposed system is composed of mechanical arm with function of anti-sway based on conventional line system. By the anti-sway arm, we can realize to prevent the sway of the container box but cannot avoid the oscillation for the overall body of the crane. So, a controller design method to solve the above stated problem must be considered. The problem is solved by adopting the velocity pattern control methods of trapezoidal and curve types and its effectiveness is proved through experimental results.

  • PDF