• Title/Summary/Keyword: expansion and contraction

Search Result 302, Processing Time 0.036 seconds

The Measurement of Real Deformation Behavior in Pilot LNG Storage Tank Membrane by using Strain Gage (스트레인 게이지를 이용한 Pilot LNG 저장탱크 멤브레인 실 변형 거동 측정)

  • Kim, Young-Kyun;Yoon, Ihn-Soo;Oh, Byoung-Taek;Hong, Seong-Ho;Yang, Young-Myung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.108-113
    • /
    • 2004
  • Korea Gas Corp. has developed the design technology of the LNG storage tank. The membrane to be applied inside of the LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature changes. It is very important to measure their thermal strains under LNG temperatures by analytical and experimental stress analysis of the membrane. We have developed a stress measurement system using strain gages and measured the strain during cooldown and storing the LNG. We also analyzed the measured data by comparison with the FEM data. On the basis of these results, we could design and assure the application of the Kogas Membrane to large scale LNG storage.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete by Fire Damage According to Design Compressive Strength (화재피해를 입은 콘크리트의 폭렬에 대한 설계기준강도의 영향성 검토에 관한 연구)

  • Na, Chul-Sung;Cho, Bong-Suk;Kim, Jae-Hwan;Kwon, Yung-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.465-468
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, this study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design compressive strength.

  • PDF

Analysis of Upper Arm Development for Sleeve Armhole Line (소매 진동둘레선 설계를 위한 위팔 체표전개도 분석에 관한 연구)

  • 이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.7
    • /
    • pp.892-900
    • /
    • 1998
  • This study was done to analyze the surface development of upper arm for planning sleeve armhole line. The major conclusions of this study are: 1. The surface development by arm movements made the expansion and contraction of upper arm surface changes easily visible. Armhole lines of 90$^{\circ}$and 135$^{\circ}$~180$^{\circ}$movements deviated from those of standard posture. 2. According to regression analysis, armhole lines on the upper arm were adapted to sleeve patten, following the axillary circumference line changed to biceps line. Sleeve cap length ranged from armhole/4+2.5cm to armhole/4$\pm$0.5cm. 3. Compared to Rim's pattern method, ascending and descending amounts of armhole lines were represented as fixed values.

  • PDF

The Standardized Methods for Improvement of Maintenance Deterioration caused by Fire damage (국제 표준화를 위한 화재이후의 유지관리 시스템 개발)

  • Kwon, Young-Jin;Koo, In-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.230-231
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

A Visualization Method for Wood Cracking Phenomenon based on the Moisture Variations (수분변화량에 따른 목재의 균열 현상 가시화 방안)

  • Kang, Jaesin;Kim, Jaewon;Ahn, Eunyoung
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1275-1280
    • /
    • 2016
  • This research is for the visualization of wooden cracking phenomena in the virtual world. Timber supplies has been traditionally used for buildings in the all over the world. Wood has a characteristic that is more prone to be influenced and distorted under the external environments compared with other materials like as stone and concrete. Many related researches say that moisture content change is a largest impact factor for the distortion and crack of timber supplies. This is the reason why we focus on the relationship between the moisture variations and the wood distortion, especially crack. In this research, it is mathematically explained that the diminutions of tensile strength caused by repeated contraction and expansion according to the moisture variations under the changes of weather. Finally, we suggest a way to visualize it for pine timbers.

Synthesis of TiCx Powder via the Underwater Explosion of an Explosive

  • Tanaka, Shigeru;Bataev, Ivan;Hamashima, Hideki;Tsurui, Akihiko;Hokamoto, Kazuyuki
    • Metals and materials international
    • /
    • v.24 no.6
    • /
    • pp.1327-1332
    • /
    • 2018
  • In this study, a novel approach to the explosive synthesis of titanium carbide (TiC) is discussed. Nonstoichiometric $TiC_x$ powder was produced via the underwater explosion of a Ti powder encapsulated within a spherical explosive charge. The explosion process, bubble formation, and synthesis process were visualized using high-speed camera imaging. It was concluded that synthesis occurred within the detonation gas during the first expansion/contraction cycle of the bubble, which was accompanied by a strong emission of light. The recovered powders were studied using scanning electron microscopy and X-ray diffraction. Submicron particles were generated during the explosion. An increase in the carbon content of the starting powder resulted in an increase in the carbon content of the final product. No oxide byproducts were observed within the recovered powders.

Structural Durability Analysis due to Hole Configuration Variation of Bike Disc Brake (자전거 디스크 브레이크 구멍 형상 변화에 따른 구조적 내구성 해석)

  • Han, Moonsik;Cho, Jaeung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.44-49
    • /
    • 2014
  • As expansion and contraction of bike disk brake are happened continuously by temperature at repeated urgent braking. In this study, 3 kinds of model are designed according to configurations of holes and thermal durabilities on bike disk brake are investigated by comparing 3 models through temperature and thermal analyses. Maximum thermal stress happened at the disk contacted with pad and the connection part fixing disk rotor. Instead of initial state, the temperature is uniformly distributed at transient state. As the area of hole at disk rotor face becomes wider, thermal stress becomes lower at the initial state. On the other hand, in case the number of holes increases, thermal stress becomes lower at the elapsed time of 100 seconds. The thermal durability of bike disk brake can be improved by applying this study result with configurations of holes.

A Study of the field application on fully Dry-process Waterproofing system (건식방수공법의 현장적용 사례 연구)

  • Yoon kwang-Pil;Moon So-Hyun;Jang Jin-Ho;Jang Sung-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.197-202
    • /
    • 2005
  • This study started to confirm and prove for the applicability of the dry-process waterproofing system to cover the defects of the wet-process waterproofing system according to weather circumstance, foundation condition and maintenance, etc. This process has triple combined waterproofing system using asphalt sheet, metal sheet, engineering plastic film. It is not influenced by the concrete's crack as the foundation of the roof according to the movement of the building because the waterproofing system is designed for maintaining good quality by absorbing the stress of contraction and expansion that is occurred by the variation of temperature. Ali components used in this process can be recycled environmentally. The superiority of this process proved and reconfirmed through with the investigation of about 130 fields, around 30,000nf for two years.

  • PDF

The Effective Parallel Processing Method for the Skeleton Improvement of Character Patterns (문자 패턴의 골격화 향상을 위한 효과적인 병렬 처리 방법)

  • Shin Choong Ho
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.1
    • /
    • pp.27-33
    • /
    • 2005
  • In this paper, an effective skeleton method is proposed in order to obtain an enhanced digital image of skeleton line. The binary image using the threshold values is applied in the preprocessing stage and then The proposed method is applied to obtain the improved image of skeleton line. We used the existing skeleton methods and SPTA(Shin's Parallel Thinning Algorithm) method for the comparison. The demerits of the existing skeleton methods have a result of noise branch, expansion and contraction. and then we are proposed a SPTA method.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete by Fire Damage According to Curing Conditions (화재피해를 입은 콘크리트의 폭력에 대한 양생조건의 영향성 검토에 관한 연구)

  • Na, Chul-Sung;Kim, Young-Sun;Kim, Jae-Hwan;Kwon, Yung-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.557-560
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, this study is willing to propose fundamental data for accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the curing conditions.

  • PDF