• 제목/요약/키워드: existing buildings

검색결과 1,282건 처리시간 0.024초

프랑스 고건축물의 보존 및 리모델링 방법에 관한 연구 - 비주거 및 공공건물 중심으로 - (Case Study on Remodeling Methods & Conservation of Ancient Buildings remodeled in France - Focusing on the examples of Non-Residential & Public Buildings -)

  • 김소영
    • 한국디지털건축인테리어학회논문집
    • /
    • 제9권3호
    • /
    • pp.5-13
    • /
    • 2009
  • This study examined public building remodeling projects in France. Through investigating cases of ancient buildings remodeled in France, the study aimed to provide fundamental data and analysis for remodeling public buildings. Accordingly, seven cases were analyzed in terms of remodeling methods, architectural characteristics, methods of conservation, and restoration of ancient historical buildings, as well as a change of usage of an existing building. As a result, this study found the criteria of French ancient building remodeling. The remodeling methods of an existing building vary in their goals and strategies depending on how the old architectural elements are persevered, as well as how new elements are added to form their unique characteristics. Thus, the remodeling methods are classified into four types based on causes: restoration, extension, renovation and rebuilding. Such methods are used jointly rather than individually. The ancient building remodeling is the process of recreating new functions and new artistic values to preserve the cultural and artistic values of existing historic buildings.

  • PDF

기존 건축물의 운영단계 에너지효율 개선을 위한 관리 및 제도화 방안 연구 (A Study on the Institutionalization of Energy Efficient Operation and Maintenance Program for Existing Buildings)

  • 조진균;이영재
    • 한국태양에너지학회 논문집
    • /
    • 제40권3호
    • /
    • pp.33-42
    • /
    • 2020
  • Operational energy is the energy that is used during the occupancy stage of building life cycle. It is associated with relatively longer proportion of infrastructure's service life and can constitute 80-90% of the total energy. Assessing the energy use in buildings is essential since they are significant contributors to energy demand. In this regard, energy performance of buildings has become the focus of many regulations. This paper aimed to review the regulations about the energy performance of buildings during their operational stage in Korea. For energy efficient operation program for existing buildings, governments should implement policies and support voluntary programs that rely on collecting and managing building performance data and using this data to inform public and private-sector operation and maintenance strategies. Implementing these policies and programs requires tools and processes for collecting, curating, managing, analyzing, and publishing this data. Energy assessment tool, that is a data resource management tool that enables to assess energy use across the entire portfolio of buildings, is also required.

Site classes effect on seismic vulnerability evaluation of RC precast industrial buildings

  • Yesilyurt, Ali;Zulfikar, Abdullah C.;Tuzun, Cuneyt
    • Earthquakes and Structures
    • /
    • 제21권6호
    • /
    • pp.627-639
    • /
    • 2021
  • Fragility curves are being more significant as a useful tool for evaluating the relationship between the earthquake intensity measure and the effects of the engineering demand parameter on the buildings. In this paper, the effect of different site conditions on the vulnerability of the structures was examined through the fragility curves taking into account different strength capacities of the precast columns. Thus, typical existing single-story precast RC industrial buildings which were built in Turkey after the year 2000 were examined. The fragility curves for the three typical existing industrial structures were derived from an analytical approach by performing non-linear dynamic analyses considering three different soil conditions. The Park and Ang damage index was used in order to determine the damage level of the members. The spectral acceleration (Sa) was used as the ground motion parameter in the fragility curves. The results indicate that the fragility curves were derived for the structures vary depending on the site conditions. The damage probability of exceedance values increased from stiff site to soft site for any Sa value. This difference increases in long period in examined buildings. In addition, earthquake demand values were calculated by considering the buildings and site conditions, and the effect of the site class on the building damage was evaluated by considering the Mean Damage Ratio parameter (MDR). Achieving fragility curves and MDR curves as a function of spectral acceleration enables a quick and practical risk assessment in existing buildings.

기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로- (Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam -)

  • 김현태;김원진
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

Simplified methods for seismic assessment of existing buildings

  • Tehranizadeh, Mohsen;Amirmojahedi, Maryam;Moshref, Amir
    • Earthquakes and Structures
    • /
    • 제10권6호
    • /
    • pp.1405-1428
    • /
    • 2016
  • Besides the complex instructions of guidance documents for seismic rehabilitation of existing buildings, some institutions have provided simple criteria in terms of simplified rehabilitations. ASCE 41-06 is one of documents that introduced a simple method for assessment of certain buildings that do not require advanced analytical procedures. Furthermore the New Zealand guideline has presented a simple lateral mechanism analysis that is a hand static analysis for determining the probable collapse mechanism, lateral strength and displacement capacity of the structure. The present study is focused on verifying the results of the simplified methods which is used by NZSEE and ASCE 41-06 in assessment of existing buildings. For this, three different special steel moment and braced frames are assessed under these two guidelines and the accuracy of the results is checked with the results of nonlinear static and dynamic analysis. After comparison of obtained results, suggestions are presented to improve seismic retrofit criteria.

An actively controlled prototype for educational buildings

  • Casciati, S.;Faravelli, L.
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.105-109
    • /
    • 2020
  • The authors address the problem of ameliorating or updating existing educational buildings. This building typology is quite sensitive to social and media pressure, mainly when accidents have occurred nearby. When a building is classified as unsatisfactory, the current code requirements oblige one to re-design the building with significant penalty factors in the resistance values. Often the only solution is to destroy the existing facility and to build a new one. When attempting to preserve the existing building, higher levels of safety are demanded by the society and this can only be achieved by innovative system architectures. The authors propose and discuss a prototype that can be easily adopted to retrofit small educational buildings as the ones common in small municipalities. The higher performance is pursued by a special design of the control scheme, with new control devices and special control laws.

도서관건축의 리모델링 수법 (A Study on Remodeling Method of Library Architecture)

  • 이지영
    • 교육시설 논문지
    • /
    • 제24권1호
    • /
    • pp.3-10
    • /
    • 2017
  • This study is to analyze the remodeling method of library in terms of space extension method and urban regeneration by repurposing function in unused facilities through case study. In many case of library extension, horizontal extensions are more frequent than vertical extensions, because there are limits to extend vertically due to high live load estimation by book stacks. Extension schemes was organized by new building extension method in connection with existing buildings, attaching method small scaled mass or linear mass to existing building, connecting method a plurality of existing small buildings, vertical extension method on the top of the structure, underground extension method using special structure. Unused facility remodeling to the library, large scaled buildings can be developed completely to the function of the library through the relocation of the space, while small scaled building needs spatial extension. In the case of spatial extension, existing space that was used for other purposes can be used as a reading room or office, avoiding high live load estimation.

챗봇 활용 철근콘크리트 건축물 구조안전 자가점검 시나리오 개발에 관한 연구 (Development of Chatbot Self-Inspection Scenario for Structural Safety of Existing Reinforced Concrete Buildings)

  • 양재광;강태욱;신지욱
    • 한국지진공학회논문집
    • /
    • 제27권6호
    • /
    • pp.331-337
    • /
    • 2023
  • Due to the aging of a building, 38.8% (about 2.82 million buildings) of the total buildings are old for more than 30 years after completion and are located in a blind spot for an inspection, except for buildings subject to regular legal inspection (about 3%). Such existing buildings require users to self-inspect themselves and make efforts to take preemptive risks. The scope of this study was defined as the general public's visual self-inspection of buildings and was limited to structural members that affect the structural stability of old buildings. This study categorized possible damage to reinforced concrete to check the structural safety of buildings and proposed a checklist to prevent the damage. A damage assessment methodology was presented during the inspection, and a self-inspection scenario was tested through a chatbot connection. It is believed that it can increase the accessibility and convenience of non-experts and induce equalized results when performing inspections, according to the chatbot guide.

하중제한이 기존건물의 옥상조경계획에 미치는 영향 (Influence of Load Limitation on the Roofspace Planning of Existing Buildings)

    • 한국조경학회지
    • /
    • 제26권2호
    • /
    • pp.166-180
    • /
    • 1998
  • In a city where the greenery always lacks landscaping roofs of existing buildings offers a way to solve the problem. But the most serious problem that poses is the matter of load limit. At present most existing buildings have the loading capacity of 200 kg/$m^2$ or less on their roofs. If the natural soil is used the loading capacity is easily surpassed because it simply is too heavy. To alleviate this problem it is realized to introduce the light weight artificial soil. The specific gravity of light soil is 0.65 whereas the natural soil is 1.8 when wet. It is three times lighter than the natural soil, thus eases the burden to the roof. The next problem to be confronted is the plant species to plant. It is possible to plant trees but they soon outgrow the loading capacity by weighing 8 times heavier in 10 years. Therefore shrubs and perennials are suggested to be planted because they don't weigh much even when they reach the mature height. The last problem is the stress put on roofs by the weight of the users. By some unexpected event the crowd gathered on a weak roof can cause the structural damage or even the collapse of the roof. The avoid the possibility of collapse a plaza or big pocket should not be designed in a roof garden because they hold crowd. By following the suggested means the old roofs of existing buildings can turn into the urban oases in the sky.

  • PDF

기존 건축물의 사용승인허가 전·후 거주환경을 고려한 화재피난성능평가 연구 (A Study on the Fire Evacuation Assessment Considering Occupied Environment Variation in Existing Buildings)

  • 김학경;최두찬;김인태;김희문;심혜인
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.105-110
    • /
    • 2016
  • 국내 건축물의 다양한 거주목적과 특성에 따른 재실자가 거주하게 됨에 발생되는 내부 인테리어 공사 등을 포함한 건축변경으로 인해 증대되는 화재위험성에 대한 분석과 대응은 미비하다. 건축피난성능이 저하된 기존 건축물이 늘어갈수록 화재사고가 발생할 가능성이 높아짐에 따라 체계적인 화재위험도평가를 수행하여, 화재위험을 저감하고 관리할 수 있는 제도적 장치와 평가기법을 개발이 필요하다. 본 연구는 그 첫 번째 과정으로서 기존 건축물 3개소에 대해서 1단계는 현장조사, 2단계는 화재피난성능평가를 진행하여 문제점을 분석하고 개선방안의 제안을 목적으로 진행하였다.