• 제목/요약/키워드: exhaust system

검색결과 1,694건 처리시간 0.027초

13" 비대칭 DPF 내 형상에 따른 배압 및 유동균일도 영향에 관한 전산해석연구 (CFD Analysis on Effect of Pressure Drop and Flow Uniformity with Geometry in 13" Asymmetric DPF)

  • 한단비;변현승;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.614-621
    • /
    • 2020
  • Recently, as the fine dust is increased and the emission regulations of diesel engines are strengthened, interest in diesel soot filtration devices is rapidly increased. In particular, there is a demand for technology development for higher efficiency of diesel exhaust gas after-treatment devices. As part of this, many studies conducted to increase the exhaust gas treatment efficiency by improving the flow uniformity of the exhaust gas in the DPF and reducing the pressure drop between the inlet and outlet of disel particle filter (DPF). In this study, computational fluid dynamics (CFD) simulation was performed when exhaust gas flows into the canning reduction device equipped with a 13" asymmetric DPF in order to maintain the flow uniformity in the diesel exhaust system and reduce the pressure. In particular, a study was conducted to find the geometry with the smallest pressure drop and the highest flow uniformity by simulating the DPF I/O ratio, exhaust gas temperature, inlet-outlet pressure and flow uniformity according to the geometry and hole size of distributor.

화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석 (A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station)

  • 신규호;허남건;원찬식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

급배기 방식 개선에 따른 생물안전 밀폐시설의 Risk Assessment와 초기 건설비 저감에 대한 연구 (A Study on the Risk Assessment and Reduction of Initial Construction Cost in a Biosafety Laboratory According to Improvement of Supply and Exhaust Method)

  • 황지현;홍진관;주영덕
    • 설비공학논문집
    • /
    • 제25권10호
    • /
    • pp.534-539
    • /
    • 2013
  • In general, entire supply air of the BSL3 laboratory should be vented to the outside for its biosafety and the air conditioning system should always be operating to maintain a room pressure difference. In this regard, annual energy consumption is approximately five or ten times greater than the magnitude of the office building. In addition, to adjust room pressure difference to the set value efficiently, the supply and exhaust duct system are installed in each room of the BSL3 lab. Thus, initial construction cost is extremely high. In this study, multizone simulation is performed to estimate maintaining the appropriate room pressure difference in the case of changing model A (each room supply and exhaust system) to model B (each zone supply and exhaust system) for verification of the BSL3 lab biosafety. Also, in the case of these two models, the multizone simulation for three kinds of biohazard scenario is performed as part of risk assessment. The analysis of initial construction cost of two models is conducted for comparison. According to the studies, initial construction cost of model B is less than about 22% of existing model A. Moreover, biosafety of the BSL3 lab is still maintaining in the case of the two models.

대면교행터널에서 배연시스템의 구축과 화재모형실험에 의한 적정성 평가 (Construction of the Smoke Exhaust System and Its Applicability by the Fire Model Test for a Bidirectional Tunnel)

  • 이상은;이창우
    • 터널과지하공간
    • /
    • 제15권6호
    • /
    • pp.452-461
    • /
    • 2005
  • 대면 교행 터널의 경우 차량의 교행으로 사고 위험성이 일방향 터널에 비해 1.5배 정도 높으므로 화재가 발생할 위험성도 커지게 되며, 터널내 화재시 입출구로 이용객이 대피하므로 인명 대피 완료전까지 제트팬을 가동하지 못하는 문제가 있다. 특히 장대터널의 경우 연기확산으로 인하여 대형 인명 피해가 발생하기 때문에 터널내에 별도의 인명 대피 통로와 배연 시스템을 구축하여 인명 피해를 최소화하는 것이 필요하다. 본 연구에서는 화재 시뮬레이션 및 축소모형실험을 수행하여 터널내에 구축된 배연시스템의 효과를 검증하였다. 실험결과 대피 통로만 설치시는 최종 인명 대피 시간이 335초가 소요되었으나, 배연 시스템을 구축할 때는 185초가 소요되었다. 또한 화재원 부근의 온도가 $60^{\circ}C$ 정도 감소되었으며, 연기 확산 속도는 배연 시스템 미가동시 $0.36\~0.82\;m/sec$이고, 가동시는 $0.27\~0.58\;m/sec$로 현격히 감소하였다. 위 결과로부터 대피자의 이동속도가 $0.7\~1.0\;m/sec$인 점을 고려할 때, 150 m 간격으로 설치된 피난문을 통해 안전한 대피가 가능하였다. 본 연구는 배연시스템에 대한 화재모형실험 분석을 통해 향후 대면 교행 터널의 방재에 대한 기초자료를 제공하는데 그 의미가 있다.

선박용 소음기 성능 시험 및 평가 (Performance Test and Evaluation of Ship Exhaust Huffier)

  • 김봉기;김상렬;김현실;신민철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.158-163
    • /
    • 2008
  • Muffler design in the exhaust system is critical to provide for low noise in shipboard spaces. In an attempt to effectively design the low noise muffler, it is important to evaluate the performance of the muffler considering not only the noise, but also pressure drop as well. For this purpose, a test system of large exhaust muffler for ship propulsion systems was designed based on ISO 7235. The substitution test for determining both the insertion loss and pressure drop of mufflers was carried out. A ship exhaust muffler is considered as a test example and the insertion loss and pressure drop are obtained.

  • PDF

비파괴법에 의한 선박용 디젤엔진 배기밸브의 열화도 평가에 관한 기초적 연구 (Fundamental Study on Degradation Evaluation of Marine Diesel Engine Exhaust Valve by Nondestructive Test)

  • 심규현;김현수;남기우
    • 동력기계공학회지
    • /
    • 제3권4호
    • /
    • pp.51-56
    • /
    • 1999
  • The ultrasonic method, which is well known as nondestructive test method, is widely used to evaluate the material damage due to degradation. However, this method is just used for measuring the crack size and the thickness loss of the tube. The purpose of this study is to investigate the applicability of the ultrasonic technique for the evaluation of marine diesel engine exhaust valve and to suggest the correlations between the ultrasonic characteristics and valve degradation. From the evaluation of the results obtained, the technique of using the ultrasonic property was founds to be a efficient method to evaluate the degree of marine diesel engine exhaust valve by nondestructive test.

  • PDF

LDV Measurement, Flow Visualization and Numerical Analysis of Flow Distribution in a Close-Coupled Catalytic Converter

  • Kim, Duk-Sang;Cho, Yong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.2032-2041
    • /
    • 2004
  • Results from an experimental study of flow distribution in a close-coupled catalytic converter(CCC) are presented. The experiments were carried out with a flow measurement system specially designed for this study under steady and transient flow conditions. A pitot tube was a tool for measuring flow distribution at the exit of the first monolith. The flow distribution of the CCC was also measured by LDV system and flow visualization. Results from numerical analysis are also presented. Experimental results showed that the flow uniformity index decreases as flow Reynolds number increases. In steady flow conditions, the flow through each exhaust pipe made some flow concentrations on a specific region of the CCC inlet. The transient test results showed that the flow through each exhaust pipe in the engine firing order, interacted with each other to ensure that the flow distribution was uniform. The results of numerical analysis were qualitatively accepted with experimental results. They supported and helped explain the flow in the entry region of CCC.

압축착화 엔진에서 디젤-가솔린 Dual Fuel이 연소 및 배기 특성에 미치는 영향 (Fuel Injection System on Combustion and Exhaust Emissions Characteristics in Compression Ignition Engines)

  • 권석주;차준표;성기안;박성욱
    • 한국연소학회지
    • /
    • 제16권1호
    • /
    • pp.52-57
    • /
    • 2011
  • The present study describes the characteristics of combustion and exhaust emissions in compression ignition engines using diesel-gasoline dual fuel. For investigating combustion characteristics, diesel fuel was injected directly in a single-cylinder compression ignition engine with a common-rail injection system and gasoline fuel was injected into a premixed chamber installed in an intake port. In order to investigate exhaust emission characteristics, exhaust gas was measured by emission analyzer and smoke meter. The experimental results showed that cases of diesel-gasoline dual fuel combustion exhibited extended ignition delay and reduced peak combustion pressure compared to those of directly injected diesel fuel cases. Furthermore, premixed gasoline-air mixture reduced NOx emissions due to low peak of rate of heat release(ROHR).

EGR율에 따른 예혼합 압축 착화 디젤 엔진의 연소 특성 (Combustion Characteristics of Premixed Charge Compression Ignition Diesel Engine with EGR System)

  • 이창식;이기형;김대식;허성근
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.66-72
    • /
    • 2002
  • A premixed charge compression ignition engine is experimentally investigated for the reduction of NOx and smoke emissions from diesel engines. In this study, the premixed fuel is injected into the intake manifold to form homogeneous pre-mixture in the combustion chamber and then this pre-mixture is ignited by small amount of diesel fuel directly injected into the cylinder. In the premixed charge compression ignition engine, NOx and smoke concentrations of the exhaust emissions were reduced simultaneously as compared with the conventional diesel engine. But HC emission was increased with the increase of premixed ratio. Also, when EGR system was applied to the PCCI diesel engine, the effect of EGR rate on the combustion characteristics and the exhaust gas emissions was discussed.